MEAN WELL NTS-300 Series Sine Wave Output DC-AC Inverter
300W High Reliable True Sine Wave DC-AC Power Inverter
NTS-300 Series
Features
- Compact size and lightweight
- True sine wave output (THD<3%)
- High surge power up to 600W
- Fanless design
- AC output voltage and frequency selectable by DIP S.W
- No load dissipation <1.5W max. at standby saving mode
- -25°C~+65°C wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections:
- Input: Reverse polarity / DC low alarm / DC low shutdown / Over voltage
- Output: Short circuit / Overload / Over temp.
- Battery over discharge protection (Low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Carry handle accessory available (Order NO.: Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Applications
- Mobile device
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
Description
NTS-300 is a 300W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, 600W peak power, adjustable AC output voltage and frequency, -25°C~+65°C wide operating temperature range, complete protections features, and etc. Combined with batteries, the NTS-300 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.
Model Encoding
NTS – 300 – 1 12 US
- AC output socket (Type US, EU, CN, AU, UK, UN, GFCI outlet)
- DC input voltage (12: 12Vdc, 24: 24Vdc, 48: 48Vdc)
- AC output voltage (1: 100/110/115/120Vac, 2: 200/220/230/240Vac)
- Rated wattage
- Series name
Specifications
Model No. | NTS-300-112 | NTS-300-124 | NTS-300-148 | NTS-300-212 | NTS-300-224 | NTS-300-248 |
---|---|---|---|---|---|---|
Rated Power (Continuous) | 300W | 300W | 300W | 300W | 300W | 300W |
Over Rated Power (3 min) | 450W | 450W | 450W | 450W | 450W | 450W |
Surge Power (30 cycles) | 600W | 600W | 600W | 600W | 600W | 600W |
AC Output Socket
Model No. | NTS-300-112 | NTS-300-124 | NTS-300-148 | NTS-300-212 | NTS-300-224 | NTS-300-248 |
---|---|---|---|---|---|---|
Socket Type | TYPE-US | TYPE-GFCI | TYPE-UN | TYPE-EU | TYPE-CN | TYPE-UK |
Country | USA | USA | UNIVERSAL | EUROPE | CHINA | U.K |
Certificate | CB, FC, DEKRA | CB, FC | None | CB, FC, DEKRA | CB, FC, DEKRA | CB, FC, DEKRA |
Derating Curve
The derating curve shows the load percentage against ambient temperature. The load decreases as the temperature increases beyond a certain point.
Remote ON-OFF Control
Remote ON-OFF | AC Output Status |
---|---|
Open | Power inverter ON |
Short | Power inverter OFF |
AC Output Voltage, Frequency, Power Saving Mode Selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.
LED Status
Status | Green | Orange | Red |
---|---|---|---|
Normal Work | System check, Inverter OK | Remote off, Saving mode | Abnormal Status |
DC Input | 12.5~15.5Vdc, 25~31Vdc, 50~62Vdc | 11~12.5Vdc, 22~25Vdc, 44~50Vdc | <11Vdc or >15.5Vdc, <22Vdc or >31Vdc, <44Vdc or >62Vdc |
Load | <40% load | 40~80% load | >80% load |
Mechanical Specification
Dimensions and layout for installation are provided in the diagrams.
Accessory List
Carry handle (Optional accessory, Power inverter and Pull handle should be ordered separately)
MW’s Order No. | Item | Quantity |
---|---|---|
Handle | 1 | |
Foot pad | 4 | |
Screw | 2 |
Typical Application
Illustrations show the inverter used in various settings such as homes, boats, and RVs, indicating connections to battery banks and AC outlets.
Installation Manual
For detailed installation instructions, visit: http://www.meanwell.com/manual.html
FAQ
- What is the peak power of the NTS-300 inverter?
The peak power is 600W.
- What protections does the inverter offer?
It offers protections against reverse polarity, DC low alarm/shutdown, over voltage, short circuit, overload, and over temperature.
- Is the inverter suitable for outdoor use?
Yes, it is suitable for use in remote areas with no access to utility power.
- Can the output voltage and frequency be adjusted?
Yes, they can be adjusted using the DIP switch on the panel.
300W High Reliable True Sine Wave DC-AC Power Inverter
Features
- Compact size and light weight
- True sine wave output (THD<3%)
- High surge power up to 600W
Fanless design
- AC output voltage and frequency selectable by DIP S.W
- No load disspation <1.5W max. at standby saving mode -250&+650C wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
Protections :
- Input : Reverse polarity / DC low alarm / DC low shutdown / Overvoltage
- Output : Short circuit / Overload / Over temp.
- Battery over-discharge protection(Low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Carry handle accessory available(Order NO.: Carry handle, sold separately
- Conformal coating
- 3 years warranty
Applications
- Mobile device
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
Description
NTS-300 is a 300W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, 600W peak power, adjustable AC output voltage and frequency, -2++650 wide operating temperature range, complete protections features, and etc. combined with batteries, the NTS-300 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.
Model Encoding
SPECIFICATION
MODEL NO. | NTS-300-112 | NTS-300-124 | NTS-300-148 | NTS-300-212 | NTS-300-224 | NTS-300-248 | ||||||
= US, GFCI, UN | EU, CN, AU, UK, UN | |||||||||||
AC OUTPUT | RATED POWER(Continuous) | 300W | ||||||||||
OVER RATED POWER(3 Min.) | 345W | |||||||||||
PEAK POWER(10 Sec.) | 450W | |||||||||||
SURGE POWER(30 Cycles) | 600W | |||||||||||
AC VOLTAGE | Default setting set at 110VAC | Default setting set at 230VAC | ||||||||||
100 / 110 / 115 / 120Vac selectable by DIP S.W | 200 / 220 / 230 / 240Vac selectable by DIP S.W | |||||||||||
FREQUENCY | Default setting set at 60Hz±0.1Hz | Default setting set at 50Hz±0.1Hz | ||||||||||
50/60Hz selectable by DIP S.W | 50/60Hz selectable by DIP S.W | |||||||||||
WAVEFORM Note.1 | True sine wave (THD<3%) | |||||||||||
AC REGULATION | ±3.0% at rated output voltage | |||||||||||
FRONT PANEL LED | Please refer to page5 | |||||||||||
DC INPUT | DC VOLTAGE | 12V | 24V | 48V | 12V | 24V | 48V | |||||
VOLTAGE RANGE (Typ.) | 10 ~ 16.5Vdc | 20 ~ 33Vdc | 40 ~ 66Vdc | 10 ~ 16.5Vdc | 20 ~ 33Vdc | 40 ~ 66Vdc | ||||||
DC CURRENT (Typ.) | 30A | 15A | 8A | 30A | 15A | 8A | ||||||
NO LOAD DISSIPATION
(Typ.) |
NON-SAVING MODE | 10W | 10W | 12W | 10W | 10W | 12W | |||||
SAVING MODE | Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W will be changed to saving mode | |||||||||||
1.2W | 1.3W | 1.5W | 1.2W | 1.3W | 1.5W | |||||||
OFF MODE CURRENT DRAW | ≦1mA | |||||||||||
EFFICIENCY (Typ.) Note.1 | 90% | 92% | 92% | 92% | 93% | 93% | ||||||
BATTERY TYPES | Lead Acid or li-ion | |||||||||||
PROTECTION | DC INPUT | FUSE (Internal) | 30A*2 | 30A*1 | 10A*2 | 30A*2 | 30A*1 | 10A*2 | ||||
LOW |
ALARM | 11±0.3Vdc | 22±0.5Vdc | 44±1Vdc | 11±0.3Vdc | 22±0.5Vdc | 44±1Vdc | |||||
SHUTDOWN | 10±0.3Vdc | 20±0.5Vdc | 40±1Vdc | 10±0.3Vdc | 20±0.5Vdc | 40±1Vdc | ||||||
RESTART | 12.5±0.3Vdc | 25±0.5Vdc | 50±1Vdc | 12.5±0.3Vdc | 25±0.5Vdc | 50±1Vdc | ||||||
HIGH |
ALARM | 15.5±0.3Vdc | 31±0.5Vdc | 62±1Vdc | 15.5±0.3Vdc | 31±0.5Vdc | 62±1Vdc | |||||
SHUTDOWN | 16.5±0.3Vdc | 33±0.5Vdc | 66±1Vdc | 16.5±0.3Vdc | 33±0.5Vdc | 66±1Vdc | ||||||
RESTART | 15±0.3Vdc | 30±0.5Vdc | 60±1Vdc | 15±0.3Vdc | 30±0.5Vdc | 60±1Vdc | ||||||
BAT. POLARITY | By internal fuse open | |||||||||||
AC OUTPUT | OVER TEMPERATURE | Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |||||||||||
OVER LOAD (Typ.) | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. | |||||||||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||||
GFCI PROCTECTION | Design refer to UL458
(Only for “GFCI” AC socket , by request) |
None | ||||||||||
FUNCTION | REMOTE CONTROL | Power ON-OFF remote control by front panel dry contact connector (by RELAY); Open : Normal work ; Short ,Remote off | ||||||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +65℃(Refer to “Derating curve”) | ||||||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||||||||||
STORAGE TEMP., HUMIDITY | -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing | |||||||||||
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||||
SAFETY& EMC (Note.4) | SAFETY STANDARDS | CB IEC62368-1,Dekra BS EN/EN62368-1,E13,EAC TP TC 004 approved;Design refer to AS/NZS 62368.1 (Please refer to next page“AC output socket” table for more details) ; Design refer to UL458(By request) | ||||||||||
WITHSTAND VOLTAGE | DC I/P – AC O/P:3.0KVac AC O/P – FG:1.5KVac | |||||||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | |||||||||
Radiated | FCC for 112,124,148 only(expect for Type-UN) | Class A | ||||||||||
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) | Class A | |||||||||||
Harmonic Current | BS EN/EN61000-3-2 | —– | ||||||||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||||||||||
EMC IMMUNITY | BS EN/EN55024, BS EN/EN55035 | |||||||||||
Parameter | Standard | Test Level / Note | ||||||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||||||
Radiated | BS EN/EN61000-4-3 | Level 2, 3V/m | ||||||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 1, 1A/m | ||||||||||
OTHERS | MTBF | 845.6K hrs min. Telcordia TR/SR-332 (Bellcore) ; 85.3K hrs min. MIL-HDBK-217F (25℃) | ||||||||||
DIMENSION | 210*130*55mm (L*W*H) | |||||||||||
PACKING | 1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT | |||||||||||
NOTE |
|
AC Output Socket
DERATING CURVE
Remote ON-OFF Control
Remote ON-OFF | AC Output Status |
Open | power inverter ON |
Short | power inverter OFF |
AC Output Voltage、Frequency、Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW | ||||
SW1 | SW2 | SW3 | SW4 | |
OFF | OFF : | 100Vac or 200Vac |
ON : 50Hz |
ON : Saving mode |
OFF | ON : | 110Vac or 220Vac | ||
ON | OFF : | 115Vac or 230Vac |
OFF: 60Hz |
OFF: Non-Saving mode |
ON | ON : | 120Vac or 240Vac |
LED STATUS
Normal work
Abnormal status
Light
Light off
Flash
MECHANICAL SPECIFICATION
R.C Connector : JST B-XH or equivalent
Remote Control | Mating Housing | Terminal |
Pin 1,2 Open: Normal work | JST XHP
or equivalent |
JST SXH-001T
or equivalent |
Pin 1,2 Short: Remote off |
Accessory List
Carry handle (Optional accessory, Power inverter and Pull handle should ordered seperately)
- Handle
Foot pad
TYPICAL APPLICATION
- Battery Bank
- Off-Grid DC/AC Solar Inverter (NTS series)
- AC Outlet
- Utility Input (Shore)1
- AC/DC Battery Charger (PB/NPB/NPP series)
- Battery Bank
Off-Grid DC/AC - Power Inverter (NTS series)
- AC Outlet
- AC/DC Battery Charger (PB/NPB/NPP series)
- Battery Bank
- Off-Grid DC/AC Inverter (NTS series)
- AC Outlet
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
File Name:NTS-300-SPEC 2024-02-23
Documents / Resources
![]() |
MEAN WELL NTS-300 Series Sine Wave Output DC-AC Inverter [pdf] Installation Guide NTS-300 Series Sine Wave Output DC-AC Inverter, NTS-300 Series, Sine Wave Output DC-AC Inverter, Output DC-AC Inverter, DC-AC Inverter, Inverter |