MEAN WELL-logo

MEAN WELL NTS-300 Series Sine Wave Output DC-AC Inverter

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter-product

300W High Reliable True Sine Wave DC-AC Power Inverter

NTS-300 Series

Features

  • Compact size and lightweight
  • True sine wave output (THD<3%)
  • High surge power up to 600W
  • Fanless design
  • AC output voltage and frequency selectable by DIP S.W
  • No load dissipation <1.5W max. at standby saving mode
  • -25°C~+65°C wide operating temperature
  • Power ON-OFF remote control
  • Front panel indicator for operation status
  • Protections:
    • Input: Reverse polarity / DC low alarm / DC low shutdown / Over voltage
    • Output: Short circuit / Overload / Over temp.
  • Battery over discharge protection (Low voltage disconnect)
  • Suitable for lead-acid or li-ion batteries
  • Carry handle accessory available (Order NO.: Carry handle, sold separately)
  • Conformal coating
  • 3 years warranty

Applications

  • Mobile device
  • Home and office appliance
  • Power tools
  • Portable equipment
  • Vehicle
  • Yacht
  • Off-grid solar power system
  • Wireless network
  • Telecom or datacom system

Description

NTS-300 is a 300W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, 600W peak power, adjustable AC output voltage and frequency, -25°C~+65°C wide operating temperature range, complete protections features, and etc. Combined with batteries, the NTS-300 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.

Model Encoding
NTS – 300 – 1 12 US

  • AC output socket (Type US, EU, CN, AU, UK, UN, GFCI outlet)
  • DC input voltage (12: 12Vdc, 24: 24Vdc, 48: 48Vdc)
  • AC output voltage (1: 100/110/115/120Vac, 2: 200/220/230/240Vac)
  • Rated wattage
  • Series name

Specifications

Model No. NTS-300-112 NTS-300-124 NTS-300-148 NTS-300-212 NTS-300-224 NTS-300-248
Rated Power (Continuous) 300W 300W 300W 300W 300W 300W
Over Rated Power (3 min) 450W 450W 450W 450W 450W 450W
Surge Power (30 cycles) 600W 600W 600W 600W 600W 600W

AC Output Socket

Model No. NTS-300-112 NTS-300-124 NTS-300-148 NTS-300-212 NTS-300-224 NTS-300-248
Socket Type TYPE-US TYPE-GFCI TYPE-UN TYPE-EU TYPE-CN TYPE-UK
Country USA USA UNIVERSAL EUROPE CHINA U.K
Certificate CB, FC, DEKRA CB, FC None CB, FC, DEKRA CB, FC, DEKRA CB, FC, DEKRA

Derating Curve
The derating curve shows the load percentage against ambient temperature. The load decreases as the temperature increases beyond a certain point.

Remote ON-OFF Control

Remote ON-OFF AC Output Status
Open Power inverter ON
Short Power inverter OFF

AC Output Voltage, Frequency, Power Saving Mode Selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.

LED Status

Status Green Orange Red
Normal Work System check, Inverter OK Remote off, Saving mode Abnormal Status
DC Input 12.5~15.5Vdc, 25~31Vdc, 50~62Vdc 11~12.5Vdc, 22~25Vdc, 44~50Vdc <11Vdc or >15.5Vdc, <22Vdc or >31Vdc, <44Vdc or >62Vdc
Load <40% load 40~80% load >80% load

Mechanical Specification
Dimensions and layout for installation are provided in the diagrams.

Accessory List
Carry handle (Optional accessory, Power inverter and Pull handle should be ordered separately)

MW’s Order No. Item Quantity
Handle 1
Foot pad 4
Screw 2

Typical Application
Illustrations show the inverter used in various settings such as homes, boats, and RVs, indicating connections to battery banks and AC outlets.

Installation Manual
For detailed installation instructions, visit: http://www.meanwell.com/manual.html

FAQ

  1. What is the peak power of the NTS-300 inverter?
    The peak power is 600W.
  2. What protections does the inverter offer?
    It offers protections against reverse polarity, DC low alarm/shutdown, over voltage, short circuit, overload, and over temperature.
  3. Is the inverter suitable for outdoor use?
    Yes, it is suitable for use in remote areas with no access to utility power.
  4. Can the output voltage and frequency be adjusted?
    Yes, they can be adjusted using the DIP switch on the panel.

300W High Reliable True Sine Wave DC-AC Power Inverter

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (2)

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (3)

Features

  • Compact size and light weight
  • True sine wave output (THD<3%)
  • High surge power up to 600W

Fanless design

  • AC output voltage and frequency selectable by DIP S.W
  • No load disspation <1.5W max. at standby saving mode -250&+650C wide operating temperature
  • Power ON-OFF remote control
  • Front panel indicator for operation status

Protections :

  • Input : Reverse polarity / DC low alarm / DC low shutdown / Overvoltage
  • Output : Short circuit / Overload / Over temp.
  • Battery over-discharge protection(Low voltage disconnect)
  • Suitable for lead-acid or li-ion batteries
  • Carry handle accessory available(Order NO.: Carry handle, sold separately
  • Conformal coating
  • 3 years warranty

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (4)Applications

  • Mobile device
  • Home and office appliance
  • Power tools
  • Portable equipment
  • Vehicle
  • Yacht
  • Off-grid solar power system
  • Wireless network
  • Telecom or datacom system

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx

Description
NTS-300 is a 300W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, 600W peak power, adjustable AC output voltage and frequency, -2++650 wide operating temperature range, complete protections features, and etc. combined with batteries, the NTS-300 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.

Model Encoding

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (5)

SPECIFICATION

MODEL NO. NTS-300-112 NTS-300-124 NTS-300-148 NTS-300-212 NTS-300-224 NTS-300-248
 = US, GFCI, UN  EU, CN, AU, UK, UN
AC OUTPUT RATED POWER(Continuous) 300W
OVER RATED POWER(3 Min.) 345W
PEAK POWER(10 Sec.) 450W
SURGE POWER(30 Cycles) 600W
AC VOLTAGE Default setting set at 110VAC Default setting set at 230VAC
100 / 110 / 115 / 120Vac selectable by DIP S.W 200 / 220 / 230 / 240Vac selectable by DIP S.W
FREQUENCY Default setting set at 60Hz±0.1Hz Default setting set at 50Hz±0.1Hz
50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W
WAVEFORM                        Note.1 True sine wave (THD<3%)
AC REGULATION ±3.0% at rated output voltage
FRONT PANEL LED Please refer to page5
DC INPUT DC VOLTAGE 12V 24V 48V 12V 24V 48V
VOLTAGE RANGE (Typ.) 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc
DC CURRENT (Typ.) 30A 15A 8A 30A 15A 8A
NO LOAD DISSIPATION

(Typ.)

NON-SAVING MODE 10W 10W 12W 10W 10W 12W
SAVING MODE Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W will be changed to saving mode
1.2W 1.3W 1.5W 1.2W 1.3W 1.5W
OFF MODE CURRENT DRAW ≦1mA
EFFICIENCY (Typ.)           Note.1 90% 92% 92% 92% 93% 93%
BATTERY TYPES Lead Acid or li-ion
PROTECTION DC INPUT FUSE (Internal) 30A*2 30A*1 10A*2 30A*2 30A*1 10A*2
 

LOW

ALARM 11±0.3Vdc 22±0.5Vdc 44±1Vdc 11±0.3Vdc 22±0.5Vdc 44±1Vdc
SHUTDOWN 10±0.3Vdc 20±0.5Vdc 40±1Vdc 10±0.3Vdc 20±0.5Vdc 40±1Vdc
RESTART 12.5±0.3Vdc 25±0.5Vdc 50±1Vdc 12.5±0.3Vdc 25±0.5Vdc 50±1Vdc
 

HIGH

ALARM 15.5±0.3Vdc 31±0.5Vdc 62±1Vdc 15.5±0.3Vdc 31±0.5Vdc 62±1Vdc
SHUTDOWN 16.5±0.3Vdc 33±0.5Vdc 66±1Vdc 16.5±0.3Vdc 33±0.5Vdc 66±1Vdc
RESTART 15±0.3Vdc 30±0.5Vdc 60±1Vdc 15±0.3Vdc 30±0.5Vdc 60±1Vdc
BAT. POLARITY By internal fuse open
AC OUTPUT OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover
OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION Design refer to UL458

(Only for “GFCI” AC socket , by request)

None
FUNCTION REMOTE CONTROL Power ON-OFF remote control by front panel dry contact connector (by RELAY); Open : Normal work ; Short ,Remote off
ENVIRONMENT WORKING TEMP. -25 ~ +65℃(Refer to “Derating curve”)
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY& EMC (Note.4) SAFETY STANDARDS CB IEC62368-1,Dekra BS EN/EN62368-1,E13,EAC TP TC 004 approved;Design refer to AS/NZS 62368.1 (Please refer to next page“AC output socket” table for more details) ; Design refer to UL458(By request)
WITHSTAND VOLTAGE DC I/P – AC O/P:3.0KVac  AC O/P – FG:1.5KVac
EMC EMISSION Parameter Standard Test Level / Note
Radiated FCC for 112,124,148 only(expect for Type-UN) Class A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) Class A
Harmonic Current BS EN/EN61000-3-2 —–
Voltage Flicker BS EN/EN61000-3-3 —–
EMC IMMUNITY BS EN/EN55024, BS EN/EN55035
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 2, 3V/m
Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m
OTHERS MTBF 845.6K hrs min.        Telcordia TR/SR-332 (Bellcore) ;  85.3K hrs min.         MIL-HDBK-217F (25℃)
DIMENSION 210*130*55mm (L*W*H)
PACKING 1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT
NOTE
  1. Efficiency, AC regulation and THD are tested by 300W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
  2. All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
  3. Internal pre-start circuit, the setup time is 8s.
  4. The power supply is considered as an independent unit, but the final equipment still need to confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
    (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf
    Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

AC Output Socket

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (6)

DERATING CURVE

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (7)
MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (8)

Remote ON-OFF Control

Remote ON-OFF AC Output Status
Open power inverter ON
Short power inverter OFF

AC Output Voltage、Frequency、Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (9)

AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
SW1 SW2 SW3 SW4
OFF OFF : 100Vac or 200Vac  

ON : 50Hz

 

ON : Saving mode

OFF ON : 110Vac or 220Vac
ON OFF : 115Vac or 230Vac  

OFF: 60Hz

 

OFF: Non-Saving mode

ON ON : 120Vac or 240Vac

LED STATUS

Normal work

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (10)

Abnormal status MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (11)

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (12)Light
MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (13)Light off
MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (14)Flash

MECHANICAL SPECIFICATION

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (15)

R.C Connector : JST B-XH or equivalent

Remote Control Mating Housing Terminal
Pin 1,2 Open: Normal work JST XHP

or equivalent

JST SXH-001T

or equivalent

Pin 1,2 Short: Remote off

Accessory List

Carry handle (Optional accessory, Power inverter and Pull handle should ordered seperately)

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (16)

  1. Handle
  2. MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (17)Foot pad MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (18)

TYPICAL APPLICATION

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (19)

  1. Battery Bank
  2. Off-Grid DC/AC Solar Inverter (NTS series)
  3. AC Outlet

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (20)

  1. Utility Input (Shore)1
  2. AC/DC Battery Charger (PB/NPB/NPP series)
  3. Battery Bank
    Off-Grid DC/AC
  4. Power Inverter (NTS series)
  5. AC Outlet

MEAN-WELL-NTS-300-Series-Sine-Wave-Output DC-AC-Inverter- (1)

  1. AC/DC Battery Charger (PB/NPB/NPP series)
  2. Battery Bank
  3. Off-Grid DC/AC Inverter (NTS series)
  4. AC Outlet

INSTALLATION MANUAL

Please refer to : http://www.meanwell.com/manual.html

File Name:NTS-300-SPEC 2024-02-23

Documents / Resources

MEAN WELL NTS-300 Series Sine Wave Output DC-AC Inverter [pdf] Installation Guide
NTS-300 Series Sine Wave Output DC-AC Inverter, NTS-300 Series, Sine Wave Output DC-AC Inverter, Output DC-AC Inverter, DC-AC Inverter, Inverter

References

Leave a comment

Your email address will not be published. Required fields are marked *