LPV-150 Series 150W Single Output Switching Power Supply
“
Specifications:
- Model: LPV-150-12, LPV-150-15, LPV-150-24, LPV-150-36
- DC Voltage: 12V, 15V, 24V, 36V
- Rated Power: 120W (LPV-150-12, LPV-150-15), 151.2W (LPV-150-24,
LPV-150-36) - Efficiency: 87% (LPV-150-12), 88% (LPV-150-15), 89%
(LPV-150-24, LPV-150-36)
Product Usage Instructions:
1. Installation:
Ensure the power supply is disconnected before installation.
Connect the input wires to the appropriate power source following
the voltage and current requirements specified for your model.
2. Operation:
After installation, turn on the power supply and adjust the
output voltage if necessary. Monitor the load to ensure it does not
exceed the rated current.
3. Safety Precautions:
- Do not operate the power supply in wet or humid
conditions. - Avoid overloading the power supply beyond the specified limits
to prevent damage. - Keep the power supply away from flammable materials.
FAQ:
Q: What should I do if the power supply overheats?
A: If the power supply overheats, it will automatically shut
down. Allow it to cool down before attempting to power it on
again.
Q: Can I connect multiple devices to the power supply?
A: The maximum number of power supplies that can be connected
depends on the circuit breaker type and voltage. Refer to the
specifications for details.
“`
150W Single Output Switching Power Supply
LPV-150 series
User’s Manual
IP67
IS 15885(Part 2/Sec13)
THOMAS SAMUEL
THOMAS SAMUEL
R-41027766 (for LPV-150-12,24 only)
File Name:LPV,LPVL-150-SPEC 2024-12-12
Downloaded from Arrow.com.
150W Single Output Switching Power Supply
LPV-150 series
SPECIFICATION
MODEL
LPV -150-12
LPV-150-15
LPV -150-24
LPV-150-36
DC VOLTAGE
12V
15V
24V
36V
RATED CURRENT CURRENT RANGE
10A 0 ~ 10A
8A 0 ~ 8A
6.3A 0 ~ 6.3A
4.2A 0 ~ 4.2A
RATED POWER
120W
120W
151.2W
151.2W
OUTPUT
RIPPLE & NOISE (max.) Note.2 200mVp-p VOLTAGE TOLERANCE Note.3 ±5.0%
200mVp-p
200mVp-p
200mVp-p
LINE REGULATION LOAD REGULATION
±1.0% ±2.0%
SETUP, RISE TIME Note.6 LPV-150: 500ms, 50ms / 230VAC 500ms, 50ms / 277VAC;
LPVL-150: 1500ms, 50ms / 115VAC
HOLD UP TIME (Typ.)
LPV-150: 18ms/230VAC 20ms/277VAC at full load;
LPVL-150: 10ms/115VAC at full load
VOLTAGE RANGE Note.4 LPV-150: 180 ~ 305VAC 254 ~ 431VDC;
LPVL-150: 90~132VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
87%
88%
89%
89%
INPUT
AC CURRENT
LPV-150: 1.7A/230VAC 1.5A/277VAC;
LPVL-150: 3.0A/115VAC
INRUSH CURRENT Blank type COLD START 60A(twidth=900s measured at 50% Ipeak) at 230VAC
(Typ.)
L type COLD START 75A(twidth=900s measured at 50% Ipeak) at 115VAC
LPV-150-48 48V 3.2A 0 ~ 3.2A 153.6W 200mVp-p
90%
MAX. No. of PSUs Blank type
on 16A CIRCUIT
BREAKER
L type
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC 1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 115VAC
LEAKAGE CURRENT
LPV-150: 0.25mA / 240VAC
LPVL-150:0.25mA / 120VAC
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
13.5 ~ 18V
17 ~ 25V
27 ~ 35V
40 ~ 49V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-25 ~ +65 (Refer to “Derating Curve”)
20 ~ 90% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/ (0 ~ 40 for LPV-150-12,15 and LPVL-150-12,24;0~50 for LPV-150-24,36,48)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
52 ~ 63V
SAFETY STANDARDS
Blank type
UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,BIS IS15885(for LPV-150-12,24 only),EAC TP TC 004, IP67, IEC62368-1, BS EN/EN62368-1 approved
L type UL8750(type”HL”),CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved
SAFETY & EMC
OTHERS NOTE
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSION
Blank type Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A(80% load), BS EN/EN61000-3-3, EAC TP TC 020 L type Compliance to FCC part 15
EMC IMMUNITY
Blank type Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light industry level, EAC TP TC 020 L type Design refer to IEC61000-4-2,3,4,5,6,8,11; light industry level
MTBF
3361.2K hrs min. Telcordia SR-332 (Bellcore) ; 391.9Khrs min. MIL-HDBK-217F (25)
DIMENSION
191*63*37.5mm (L*W*H)
PACKING
LPV-150: 0.79Kg;20pcs/17Kg/0.98CUFT; LPVL-150: 0.79Kg;20pcs/17Kg/0.98CUFT
1. All parameters NOT specially mentioned are measured at 230VAC(115VAC for LPVL) input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure.
8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).
9. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
10. This product is not intended for LED lighting luminaire applications in the EU and China.(In the EU and China the LPF/NPF/XLG/XLC/XLN series
are recommended.)
Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:LPV,LPVL-150-SPEC 2024-12-12
Downloaded from Arrow.com.
150W Single Output Switching Power Supply
LPV-150 series
Mechanical Specification
25 AC/N(Blue) AC/L(Brown)
300±20 SJTW 18AWG
5
Case No. LPC-150 Unit:mm Tolerance:±1
191 5
63 26
2-4.5
T case
tc
96
5
tc : Max. Case Temperature
5
300±20 SJTW 14AWG
25
+V(Red) -V(Black)
37.5
3
Recommend Mounting Direction
Block Diagram
EMI FILTER
I/P
&
RECTIFIERS
O.L.P.
POWER SWITCHING
PWM CONTROL
RECTIFIERS &
FILTER
PWM fosc : 6457KHz
+V -V
DETECTION CIRCUIT O.V.P.
Derating Curve
Static Characteristics
100
LPV-150-24,36,48
80
60
LPV-150-12,15
40
LPVL-150 20
-25 -15
0
15
30
40
50
60
65 (HORIZONTAL)
AMBIENT TEMPERATURE ()
100 90 80 70 60 50 40
180 190 200 210 220 230 240 250 260 270 280 305 (Blank type)
90
100
105
120
130 132 (L type)
INPUT VOLTAGE (V) 60Hz
LOAD (%) LOAD (%)
Downloaded from Arrow.com.
File Name:LPV,LPVL-150-SPEC 2024-12-12
Documents / Resources
![]() |
MEAN WELL LPV-150 Series 150W Single Output Switching Power Supply [pdf] Owner's Manual LPV-150-12, LPV-150-15, LPV-150-24, LPV-150-36, LPV-150-48, LPV-150 Series 150W Single Output Switching Power Supply, LPV-150 Series, 150W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |