MEAN WELL LPF-40 Series Constant Voltage Plus Constant Current LED Driver
Product Specifications
MODEL | OUTPUT | RATED CURRENT | RATED POWER |
---|---|---|---|
LPF-40-12 | 12V, 7.2-12V constant current region | 3.34A | 40.08W |
LPF-40-15 | 15V, 9-15V constant current region | 2.67A | 40.08W |
LPF-40-20 | 20V, 12-20V constant current region | 2A | 40W |
LPF-40-24 | 24V, 14.4-24V constant current region | 1.67A | 40.08W |
Product Usage Instructions
Installation
- Ensure the input voltage range is compatible with the driver.
- Connect the LED load to the output terminals of the driver.
- Securely mount the driver in a well-ventilated area away from moisture.
Operation
To operate the LED driver:
- Apply the appropriate input voltage within the specified range.
- The driver will provide constant voltage or constant current output based on the connected load.
- Monitor the driver for any abnormalities such as excessive heator and unusual noises.
Maintenance
To ensure longevity and safety:
- Regularly check for dust accumulation and clean the driver if necessary.
- Avoid overloading the driver beyond its rated power and current limits.
- Replace the driver if any signs of damage or malfunction are observed.
Frequently Asked Questions
- Q: Can I use the LPF-40 series driver with any LED load?
- A: The LPF-40 series driver is designed to work with specific voltage and current ranges as indicated in the specifications. Ensure your LED load falls within these ranges for optimal performance.
- Q: What should I do if the driver overheats during operation?
- A: If the driver overheats, immediately disconnect the power\ supply and allow it to cool down before investigating the cause. Check for any obstructions to ventilation or signs of component failure.
- Q: Is the LPF-40 series driver waterproof?
- A: The LPF-40 series driver is IP67-rated, indicating it is protected against dust ingress and immersion up to a certain depth. However, always follow proper installation guidelines to maintain the waterproof integrity of the driver.
Symbol
Features
- Constant Voltage + Constant Current mode output
- Plastic housing with Class Il design
- Built-in active PFC function
- Class 2 power unit
- Fully encapsulated with IP67 level
- Typical lifetime>50000 hours
- 5 years warranty
Description
LPF-40 series is a 40W AC/DC LED driver featuring the dual modes of constant voltage and constant current output. LPF-40 operates from 90~305 VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the hign efficiency up to 90%, with the fanless design, the entire series is able to operate for -40°C ~ +80°C case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for a variety of applications at dry, damp or wet locations.
Applications
- LED panel lighting
- LED downlight
- LED decorative lighting
- LED tunnel lighting
- Moving sign
- GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Model Encoding
SPECIFICATION
MODEL | LPF-40-12 | LPF-40-15 | LPF-40-20 | LPF-40-24 | LPF-40-30 | LPF-40-36 | LPF-40-42 | LPF-40-48 | LPF-40-54 | |
OUTPUT |
DC VOLTAGE | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION Note.2 | 7.2 ~12V | 9 ~ 15V | 12 ~ 20V | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V | |
RATED CURRENT | 3.34A | 2.67A | 2A | 1.67A | 1.34A | 1.12A | 0.96A | 0.84A | 0.76A | |
RATED POWER Note.5 | 40.08W | 40.08W | 40W | 40.08W | 40.2W | 40.32W | 40.32W | 40.32W | 41.04W | |
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 350mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME Note.6 | 1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC | |||||||||
INPUT |
VOLTAGE RANGE Note.5 | 90 ~ 305VAC 127 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section) |
||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
|||||||||
TOTAL HARMONIC DISTORTION | THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) |
|||||||||
EFFICIENCY (Typ.) | 84% | 85% | 86% | 87% | 88% | 88% | 88.5% | 90% | 90% | |
AC CURRENT | 0.6A / 115VAC 0.3A / 230VAC 0.25A/277VAC | |||||||||
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC | |||||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||||
PROTECTION |
OVER CURRENT | 95 ~ 108% | ||||||||
Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 15 ~ 17V | 17.5 ~ 21V | 23 ~ 27V | 28 ~ 35V | 34 ~ 40V | 41 ~ 49V | 46 ~ 54V | 54 ~ 63V | 59 ~ 66V | |
Shut down and latch off o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +80℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | ||||||||
MAX. CASE TEMP. | Tcase=+80℃ | |||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
SAFETY & EMC |
SAFETY STANDARDS Note.8 | UL8750, CSA C22.2 No. 250.0-08, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384,EAC TP TC 004, IP67, J61347-1, J61347-2-13,GB19510.1,GB19510.14 approved ; design refer to UL60950-1 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION Note.8 | Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3, GB/T 17743 , GB17625.1,EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EAC TP TC 020 | |||||||||
OTHERS |
MTBF | 3597.9K hrs min. Telcordia SR-332 (Bellcore) ; 438.9Khrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 162.5*43*32mm (L*W*H) | |||||||||
PACKING | 0.44Kg; 32pcs/15.08Kg/0.93CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to “DRIVING METHODS OF LED MODULE”. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance: includes set up tolerance, line regulation and load regulation. 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to an increase of the set up time. 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 8. To fulfill the requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without being permanently connected to the mains. 9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less. 10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
- This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC/ POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
- ※ 48V Model, Tcase at 70℃
EFFICIENCY vs LOAD
LPF-40 series possess superior working efficiency that up to 90% can be reached in field applications.
- 48V Model, Tcase at 70℃
LIFE TIME
MECHANICAL SPECIFICATION
Recommend Mounting Direction
INSTALLATION MANUAL
Please refer to:http://www.meanwell.com/manual.html
Documents / Resources
![]() |
MEAN WELL LPF-40 Series Constant Voltage Plus Constant Current LED Driver [pdf] Owner's Manual LPF-40-12, LPF-40-15, LPF-40-20, LPF-40-24, LPF-40-30, LPF-40 Series Constant Voltage Plus Constant Current LED Driver, LPF-40 Series, Constant Voltage Plus Constant Current LED Driver, Constant Current LED Driver, Current LED Driver, LED Driver |