Features

  • Constant Voltage + Constant Current mode output
  • Metal housing with class I design
  • Built-in active PFC function
  • IP67 / IP65 rating for indoor or outdoor installations
  • Function options: output adjustable via potentiometer; 3 in 1 dimming; Timer dimming
  • Typical lifetime > 62000 hours
  • 7 years warranty

Applications

  • LED street lighting
  • LED high-bay lighting
  • Parking space lighting
  • LED fishing lamp
  • LED greenhouse lighting
  • Type “HL” for use in Class I , Division 2 hazardous (Classified) location.

GTIN CODE

Description

HLG-120H series is a 120W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-120H operates from 90- 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for-40°C – +80°C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-120H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.

Model Encoding

Model Encoding

Type IP Level Function Note
Blank IP67 Io and Vo fixed In Stock
A IP65 Io and Vo adjustable through built-in potentiometer In Stock
B IP67 3 in 1 dimming function (1 ~1 0VDC, 1 0V PWM signal and resistance) In Stock
AB IP65 Io and Vo adjustable through built-in potentiometer & 3 in 1 dimming function (1 ~1 0Vdc, 1 0V PWM signal and resistance) In Stock
D IP67 Timer dimming function, contact MEAN WELL for details(safety pending). By request

SPECIFICATION

MODEL HLG-120H-12 O HLG-120H-15D HLG-120H-20O HLG-120H-24D HLG-120H-30 D HLG-120H-36D HLG-120H-42D HLG-120H-48O HLG-120H-54D
OUTPUT DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V
CONSTANT CURRENT REGION Note.4 6 -12V 7.5 – 15V 10 – 20V 12 – 24V 15- 30V 18 – 36V 21 ~ 42V 24- 48V 27 – 54V
RATED CURRENT 10A 8A 6A 5A 4A 3.4A 2.9A 2.5A 2.3A
RATED POWER 120W 120W 120W 120W 120W 122.4W 121.8W 120W 124.2W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p
VOLTAGE ADJ. RANGE Adjustable for A/AB-Type only (via built-in potentiometer)
10.8 ~ 13.5V 13.5~17V 17 – 22V 22 – 27V 27- 33V 33-40V 38 – 46V 43- 53V 49- 58V
CURRENT ADJ. RANGE Adjustable for A/AB-Type only (via bu ilt-in potentiometer)
5 – 10A 4 – 8A 3 – 6A 2.5 – 5A 2 ~4A 1.7 – 3.4A 1.4 – 2.9A 1.2- 2.5A 1.1 – 2.3A
VOLTAGE TOLERANCE Note.3 ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ± 1.0% ± 1.0% ± 1.0%
LINE REGULATION ±0.5% ± 0.5% ± 0.5% ±0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5%
LOAD REGULATION ±2.0% ±1.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME                       Note.6 1200ms,50ms/115VAC 500ms,50ms/230VAC
HOLD UP TIME (Typ.) 12ms / 115VAC,230VAC
INPUT VOLTAGE RANGE                       Note.5 90- 305VAC        127 – 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE 47- 63Hz
POWER FACTOR (Typ.) PF;;;:;0,98/115VAC, PF;;;:;0,95/230VAC, PF;;;:; 0,93/277VAC@ full load

(Please refer to “POWER FACTOR (PF) CHARACTER ISTIC” section)

TOTAL HARMONIC DISTORTION THD< 20% (@load;;;:;50% / 115VAC,230VAC; @ load ;;;:; 75% / 277VAC)

(Please refer to “TOTAL HARMON IC DISTORTION (THD)” section)

EFFICIENCY (Typ.) 92% 92% 93% 93% 93% 93% 93% 93.5% 93.5%
AC CURRENT (Typ.) 1.4A/115VAC        0.6A/ 230VAC       0.55A/277VAC
INRUSH CURRENT (Typ.) COLD START 60A(twidth=3 75µs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER  

5 units (circuit breaker of type B) / 9 un its (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT <0.75mA/ 277VAC
PROTECTION OVER CURRENT 95 – 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 14-17V 18-21V 23 – 27V 28 – 34V 34- 38V 41 -46V 47- 53V 54- 63V 59- 65V
Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT WORKING TEMP. Tease= -40- +80°C (Please refer to “OUTPUT LOAD vs TEMPERATURE” sect ion)
MAX. CASE TEMP. Tease= +80°C
WORKING HUMIDITY 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40- +80°C, 10-95% RH
TEMP. COEFFICIENT ±0 03%(C (0 – 60°C)
VIBRATION 10-500Hz, 5G 12m in./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS Note. 8 UL8750 (type”HL”), CSA C22.2 No. 250.0-08, BS EN/EN 61347-1 , BS EN/EN 61347-2-13, AS/NZS 61347-1(except for AB-type) ,

AS/NZS 61347-2-13 (except for AB-type) independent;GB19510.1,GB 19510.14, IP65 or IP67 , J61347-1, J61347-2-13 (except for B, AB and D-type),BIS IS15885( for 12B,24B,36A,54A only), EAC TP TC 004,KC6 1347-1,KC61347-2-13(except for D-type) approved

WITHSTAND VOLTAGE I/P-O/P:3. 75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25″C/ 70% RH
EMC EMISSION                       Note.8 Compliance to BS EN/EN55015, BS EN/EN55032 Class B, BS EN/EN61000-3-2 Class C (@ load;;;:; 50%) ; BS EN/EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN6 1547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV),EAC TP TC 020
OTHERS MTBF 2185.8K hrs min. Telcordia SR-332 (Bellcore); 167.1Khrs min.        MIL-HDBK-2 17F (25″C)
DIMENSION 220′ 68′ 38.8mm (L’W’H)
PACKING 1.12Kg; 12pcs/14.4Kg/0.8CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25″C of ambient temperature.
  2. Ripple & noise are measured at 20 MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Please refer to “DRIVING METHODS OF LED MODULE”.
  5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC ” sections for details.
  6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
  7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
  8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
  9. This series meets the typical life expectancy of >62,000 hours of operation when Tease, particularly (tc) point (or TMP, per DLC), is about 75·c or less.
  10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
  11. The ambient temperature derating of 3.5″C/1OOOm with fanless models and of 5°C/1OOOm with fan models for operating altitude higher than 2000m(6500ft).
  12.  For any application note and IP waterproof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

* Product Liability Disclaimer : For detailed information please refer to httos://www.meanwell.com/serviceDisclaimer.asox

Symbols

Symbols
Symbols
Symbols

Customer Support

QR Code

Logo
MEAN WELL Logo

Documents / Resources

MEAN WELL HLG-120H-12 Series Constant Voltage Constant Current LED Driver [pdf] Owner's Manual
HLG-120H-12 Constant Voltage Constant Current LED Driver, HLG-120H-12, Constant Voltage Constant Current LED Driver, Constant Current LED Driver, Current LED Driver, LED Driver

References

Leave a comment

Your email address will not be published. Required fields are marked *