MEAN WELL CSP-3000-120 3000W Power Supply with Single Output Owner’s Manual

Dimension
Features
- AC input 180-264VAC
- Built-in active PFC function
- High efficiency up to 93%
- Forced air cooling by built-in DC fans
- Output voltage / current programmable
- Active current sharing up to 9000W(2+1)
- Built-in remote ON-OFF control/auxiliary power/ power OK signal
- Protections: Short circuit/ Overload/ Over voltage /Over temperature/ Fan failure
- Conformal coating
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- UV curing equipment
- Fish lamp
- Burn-in facility
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx.
Description
CSP-3000 is a 3KW single-output enclosed type AC/DC power supply. This series operates for 180-264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 65 C. Moreover, CSP-3000 provides vast design flexibility by equipping various built-in functions such as output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Model Encoding/ Order Information

SPECIFICATION
MODEL | CSP-3000-120 | CSP-3000-250 | CSP-3000-400 | |
OUTPUT |
DC VOLTAGE | 120V | 250V | 400V |
RATED CURRENT | 25A | 12A | 7.5A | |
CURRENT RANGE | 0 ~ 25A | 0 ~ 12A | 0 ~ 7.5A | |
RATED POWER | 3000W | 3000W | 3000W | |
RIPPLE & NOISE (max.) Note.2 | 800mVp-p | 1000mVp-p | 1200mVp-p | |
CONSTANT CURRENT REGION | 90 ~ 120V | 125 ~ 250V | 200 ~ 400V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 80ms / 230VAC at full load | |||
HOLD UP TIME (Typ.) | 10ms at full load | |||
INPUT |
VOLTAGE RANGE Note.4 | 180 ~ 264VAC 254 ~ 370VDC | ||
FREQUENCY RANGE | 47~63Hz | |||
POWER FACTOR (Typ.) | PF≧0.95/230VAC at full load | |||
EFFICIENCY (Typ.) | 92% | 92.5% | 93% | |
AC CURRENT (Typ.) | 20A/180VAC 16A/230VAC | |||
INRUSH CURRENT (Typ.) | Cold start 60A/230VAC | |||
LEAKAGE CURRENT | <0.3mA / 240VAC | |||
PROTECTION |
SHORT CIRCUIT | Shut down and latch off o/p voltage, re-power on to recover | ||
OVER CURRENT | 105 ~ 120% rated output power | |||
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 3 seconds, re-power on to recover (Please refer to the Function Manual) | ||||
OVERVOLTAGE | 127 ~ 150V | 265 ~ 315V | 420 ~ 500V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover | |||
FUNCTION |
OUTPUT VOLTAGE PROGRAMMABLE(PV) | Please refer to the Function Manual. | ||
OUTPUT CONSTANT CURRENTPROGRAMMABLE(PC) | Please refer to the Function Manual. | |||
CURRENT SHARING | Please refer to the Function Manual. | |||
AUXILIARY POWER(AUX) | 12V@0.4A | |||
REMOTE ON-OFF CONTROL | Please refer to the Function Manual | |||
ALARM SIGNAL OUTPUT | Power OK signal. Please refer to the Function Manual | |||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +65℃ (Refer to “Derating Curve”) | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | UL62368-1,Dekra seal BS EN/EN62368-1, EAC TP TC004, GB4943.1 | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||
EMC EMISSION |
Parameter | Standard | Test Level / Note | |
Conducted | BS EN/EN55032(CISPR32) | Class A | ||
Radiated | BS EN/EN55032(CISPR32) | Class A | ||
Harmonic Current | BS EN/EN61000-3-2 | —– | ||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||
EMC IMMUNITY |
BS EN/EN55035 ,BS EN/EN61000-6-2 | |||
Parameter | Standard | Test Level / Note | ||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||
Surge | BS EN/EN61000-4-5 | Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line | ||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,>95% interruptions 250 periods | ||
OTHERS | MTBF | 721.1K hrs min. Telcordia SR-332 (Bellcore) ; 80.5K hrs min. MIL-HDBK-217F (25℃) | ||
DIMENSION | 278*177.8*63.5mm (L*W*H) | |||
PACKING |
|
|||
Block Diagram
Static Characteristics
Derating Curve
Efficiency vs Load (400V Model)

DRIVING METHODS OF LED MODULE
I-V Operating Area(for PC mode only)
- CSP-3000-120CSP-3000-120
- CSP-3000-250
- CSP-3000-400
Function Manual
- Output Voltage/Current Programming
- Mode Setting
CN1:
CONDITION | MODE | FUNCTION | |
PIN5/PIN6 | SHORT | PV MODE | Output Voltage Programming |
OPEN | PC MODE | Output Current Programming |
The factory default settings: PV mode output max voltage pin5/pin6 short by jumper cap. When pull out the jumper cap,the default settings: PC mode output max constant current.
PV/PC Set adjustment
- Adjust the resistance(SVR2) can set output voltage or constant current point, the adjusting range is 20%-100% of max voltage or max constant current point.
- In the CN2, pin5/pin6 access external 10V voltage signal or 500-1KHz PWM signal can adjust the output voltage or constant current point.
CN2:PIN5/PIN6 needs to operate with a 10V sinking signal or PWM signal, Max. sink current TmA.
MODEL | 120V | 250V | 400V |
PV range | 18 ~ 120V(max.) | 37.5 ~ 250V(max.) | 60 ~ 400V(max.) |
PC range | 2.4 ~ 30A(max.) | 1.4~ 17A(max.) | 0.8 ~ 10A(max.) |
Remote ON-OFF
- Remote ON-OFF is activated by the configuration with respect to CN1 as shown in the following diagram.
Example 2.2(A): Using external voltage source
Example 2.2(B): Using internal 12V auxiliary output
Example 2.2(C): Using internal 12V auxiliary output
Connection Method
Example 2.2(A) | Example 2.2(B) | Example 2.2(C) | ||
SW Logic | Power supply output ON | SW Open(open) | SW Open(open) | SW Close(short) |
Power supply output OFF | SW Close(short) | SW Close(short) | SW Open(open) |
Alarm Signal Output
Alarm signal is sent out through “P OK” & “P OK GND” and P OK2 & P OK GND2 pins on CN1. Please acknowledge an external voltage source is required for this function.
Function | Description | Output of alarm(P OK, Relay Contact) | Output of alarm(P OK2, TTL Signal) |
P OK | The signal is “Low” when the power supply is above 80% of the rated output voltage, or, say, Power OK | Low(0.5V max at 500mA) | Low(0.5V max at 10mA) |
The signal turns to be “High” when the power supply is under 80% of the rated output voltage, or, say, Power Fail | High or open(External applied voltage, 500mA max.) | High or open(External applied voltage, 10mA max.) |
Explanation of alarm
Select Overload Protection Type
- Insert the shorting connector on CN1 that is shown in Fig 4.1, the Overload Protection Type will be “constant current limiting with delay shutdown after 3 seconds, re-power on to recover”. This is the factory default.
- Remove the shorting connector on CN1 that is shown in Fig 4.2, the Overload Protection Type will be “continuous constant current limiting”.
Current Sharing
CSP-3000 has the built-in active current sharing function and can be connected in parallel, up to 3 units, to provide higher output power as exhibited below:
- The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
- The difference in output voltages among parallel units should be less than 0.2V(Can Fine tune by SVR1).
- The total output current must not exceed the value determined by the following equation:
-
Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9
- When out current<( 50% rate current)×(Number of unit), the current shared among units may not be fully balanced.
- Under parallel operation, the “PV/PC” function is not available.
- CS+/CS- on CN1 are connected mutually in parallel(Note:CS+/CS- do not reverse connection).
Mechanical Specification
Mounting Instruction
Hole No. | Recommended Screw Size | MAX. Penetration Depth L | Recommended mounting torque |
1 | M4 | 5mm | 7~10Kgf-cm |
Control Pin No. Assignment (CN1) : HRS DF11-10DP-2DS or equivalent
Mating Housing | HRS DF11-10DS or equivalent |
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function | Description |
1 | RCG | Remote ON-OFF Ground |
2 | P-OK-2 | Power OK Signal(TTL Signal) |
3 | RC | Remote ON-OFF |
4 | P-OK-GND-2 | Power OK Ground |
5 | GND | PV/PC Mode Choose Ground |
6 | Mode | PV/PC Mode Choose |
7 | P-OK | Power OK Signal(Relay Contact) |
8 | CS+ | Current Sharing Signal+ |
9 | P-OK GND | Power OK Ground |
10 | CS- | Current Sharing Signal- |
Control Pin No. Assignment (CN2) : HRS DF11-8DP-2DS or equivalent
Mating Housing | HRS DF11-8DS or equivalent |
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function | Description |
1 | 12V AUXG | Auxiliary output GND |
2 | 12V AUX+ | Auxiliary output+ |
3 | NC | |
4 | NC | |
5 | PV/PC+ | PV/PC adjust+ |
6 | PV/PC- | PV/PC adjust- |
7 | NC | |
8 | NC |
Note: NC pins, please keep open circuit and do not connect to other pins/signals.
LED status indication
AC Input Terminal Pin No. Assignment
DC Output Terminal Pin No. Assignment
Installation Manual