Features

  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 second
  • Protections: Short circuit / Overload / Over voltage /Over temperature
  • Cooling by free air convection
  • 1U low profile
  • Withstand 5G vibration test
  • LED indicator for power on
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • High operating temperature up to 70°C
  • Operating altitude up to 5000 meters (Note.8)
  • High efficiency, long life and high reliability
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus

GTIN CODE

 

 

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

LRS-200 series is a 200W single-output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-200 that the whole series operates from -25°C through 70°C under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. LRS-200 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as IEC/UL 62368-1. LRS-200 series serves as a high price-to-performance power supply solution for various industrial applications.

Model Encoding

MEAN WELL LRS-100 Series Single Output Switching Power Supply - fig

SPECIFICATION

MODEL LRS-100-3.3 LRS-100-5 LRS-100-12 LRS-100-15 LRS-100-24 LRS-100-36 LRS-100-48
OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 36V 48V
RATED CURRENT 20A 18A 8.5A 7A 4.5A 2.8A 2.3A
CURRENT RANGE 0 ~ 20A 0 ~ 18A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.8A 0 ~ 2.3A
RATED POWER 66W 90W 102W 105W 108W 100.8W 110.4W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 120mVp-p 150mVp-p 200mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 2.97 ~ 3.6V 4.5 ~ 5.5V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 32.4 ~ 39.6V 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.5 ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 500ms, 30ms/230VAC
500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.) 55ms/230VAC
10ms/115VAC at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC
120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 84.5% 86% 88% 88.5% 90% 90.5% 91%
AC CURRENT (Typ.) 1.9A/115VAC         1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
PROTECTION OVER LOAD 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 8) SAFETY STANDARDS UL 62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1,

BSMI CNS15598-1, EAC TP TC 004,S/NZS62368.1(by CB),KC K60950-1(for LRS-100-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved

WITHSTAND VOLTAGE I/P-O/P:4KVAC  I/P-FG:2KVAC  O/P-FG:1.25KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,

heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)

OTHERS MTBF 3348.9K hrs min.     Telcordia SR-332 (Bellcore) ; 677.4Khrs min.       MIL-HDBK-217F (25℃)
DIMENSION 129*97*30mm (L*W*H)
PACKING 0.33Kg ; 40pcs/14.2Kg/0.87CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  7. The ambient temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m(6500ft).
  8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf
  9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.

* Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN WELL LRS-100 Series Single Output Switching Power Supply - Block Diagram

Derating Curve

MEAN WELL LRS-100 Series Single Output Switching Power Supply - Derating Curve

Static Characteristics

MEAN WELL LRS-100 Series Single Output Switching Power Supply - Static Characteristics

Mechanical Specification

MEAN WELL LRS-100 Series Single Output Switching Power Supply - Mechanical Specification

Installation Manual
Please refer to : http://www.meanwell.com/manual.html