MEAN WELL LPV-100 100W Single Output Switching Power Supply
Features
- Constant voltage design
- Universal AC input/ Full range
- Fully encapsulated with IP67 level (Note.7)
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit/ Overload/Over voltage
- Fully isolated plastic case
- Cooling by free air convection
- 100% full load burn-in test
- Low cost, high reliability
- Suitable for LED-related fixtures or appliances (such as LED Decoration or Advertisement devices) (Note.11)
- 2 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | LPV-100-5 | LPV-100-12 | LPV-100-15 | LPV-100-24 | LPV-100-36 | LPV-100-48 | ||||
OUTPUT |
DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V | |||
RATED CURRENT | 12A | 8.5A | 6.7A | 4.2A | 2.8A | 2.1A | ||||
CURRENT RANGE | 0 ~ 12A | 0 ~ 8.5A | 0 ~ 6.7A | 0 ~ 4.2A | 0 ~ 2.8A | 0 ~ 2.1A | ||||
RATED POWER | 60W | 102W | 100.5W | 100.8W | 100.8W | 100.8W | ||||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | ||||
VOLTAGE TOLERANCE Note.3 | ±8.0% | ±5.0% | ||||||||
LINE REGULATION | ±1.0% | |||||||||
LOAD REGULATION | ±6.0% | ±2.0% | ||||||||
SETUP, RISE TIME | Note.6 | 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC | ||||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 14ms/115VAC at full load | |||||||||
INPUT |
VOLTAGE RANGE | Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ.) | 80% | 85% | 87% | 88% | 88% | 89% | ||||
AC CURRENT | 2.2A/115VAC 1.2A/230VAC | |||||||||
INRUSH CURRENT(Typ.) | COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC | |||||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC | |||||||||
LEAKAGE CURRENT | 0.25mA / 240VAC | |||||||||
PROTECTION |
OVERLOAD | 110 ~ 150% rated output power | ||||||||
Protection type: Hiccup mode, recovers automatically after the fault condition is removed | ||||||||||
OVERVOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | ||||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||||
ENVIRONMENT |
WORKING TEMP. | -25 ~ +70℃ (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC |
SAFETY STANDARDS | UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,BIS IS15885(for LPV-100-12,LPV-100-24 only), EAC TP TC 004,IP67, IEC62368-1 , BS EN/EN62368-1 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A(≤80% load), BS EN/EN61000-3-3, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light industry level, EAC TP TC 020 | |||||||||
OTHERS |
MTBF | 4497.1K hrs min. Telcordia SR-332 (Bellcore) ; | 681.6Khrs min. | MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 190*52*37mm (L*W*H) | |||||||||
PACKING | 0.63Kg;20pcs/13.6Kg/0.55CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation, and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with the final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Tuning ON/OFF the power supply may lead to an increase in the setup time. 7. Suitable for indoor use or outdoor use without direct sunlight exposure. 8. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 C/1000m with fan models for operating altitudes higher than 2000m(6500ft) 9. Products sourced from the Americas regions may not have the TUVBIS/CCC logo. Please contact your MEAN WELL sales for more information. 10. For any application note and IP waterproof function installation caution, please refer to our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf 11. This product is not intended for LED lighting luminaire applications in the EU. (In the EU the LPFNPF/XLG series are recommended.) product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
Recommend Mounting
Block Diagram
Derating Curve
Static Characteristics
Documents / Resources
![]() |
MEAN WELL LPV-100 100W Single Output Switching Power Supply [pdf] User Manual LPV-100, 100W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, LPV-100, Power Supply |