MEAN-WELL-logo

MEAN WELL LPV-100 100W Single Output Switching Power Supply

MEAN-WELL-LPV-100-100W-Single-Output-Switching-Power-Supply-product

Features

  • Constant voltage design
  • Universal AC input/ Full range
  • Fully encapsulated with IP67 level (Note.7)
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit/ Overload/Over voltage
  • Fully isolated plastic case
  • Cooling by free air convection
  • 100% full load burn-in test
  • Low cost, high reliability
  • Suitable for LED-related fixtures or appliances (such as LED Decoration or Advertisement devices) (Note.11)
  • 2 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL LPV-100-5 LPV-100-12 LPV-100-15 LPV-100-24 LPV-100-36 LPV-100-48
 

 

 

 

OUTPUT

DC VOLTAGE 5V 12V 15V 24V 36V 48V
RATED CURRENT 12A 8.5A 6.7A 4.2A 2.8A 2.1A
CURRENT RANGE 0 ~ 12A 0 ~ 8.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 2.8A 0 ~ 2.1A
RATED POWER 60W 102W 100.5W 100.8W 100.8W 100.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.3 ±8.0% ±5.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±6.0% ±2.0%
SETUP, RISE TIME Note.6 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC
HOLD UP TIME (Typ.) 50ms/230VAC           14ms/115VAC at full load
 

 

INPUT

VOLTAGE RANGE Note.4 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 80% 85% 87% 88% 88% 89%
AC CURRENT 2.2A/115VAC 1.2A/230VAC
INRUSH CURRENT(Typ.) COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT 0.25mA / 240VAC
 

PROTECTION

OVERLOAD 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after the fault condition is removed
OVERVOLTAGE 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 41.4 ~ 48.6V 55.2 ~ 64.8V
Protection type: Shut down o/p voltage, re-power on to recover
 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

 

SAFETY & EMC

SAFETY STANDARDS UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,BIS IS15885(for LPV-100-12,LPV-100-24 only), EAC TP TC 004,IP67, IEC62368-1 , BS EN/EN62368-1 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC
ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2  Class A(≤80% load), BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light industry level, EAC TP TC 020
 

OTHERS

MTBF 4497.1K hrs min.       Telcordia SR-332 (Bellcore) ; 681.6Khrs min. MIL-HDBK-217F (25℃)  
DIMENSION 190*52*37mm (L*W*H)
PACKING 0.63Kg;20pcs/13.6Kg/0.55CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with the final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Tuning ON/OFF the power supply may lead to an increase in the setup time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure.
8. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 C/1000m with fan models for operating altitudes higher than 2000m(6500ft)
9. Products sourced from the Americas regions may not have the TUVBIS/CCC logo. Please contact your MEAN WELL sales for more information.
10. For any application note and IP waterproof function installation caution, please refer to our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
11. This product is not intended for LED lighting luminaire applications in the EU. (In the EU the LPFNPF/XLG series are recommended.)
product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-LPV-100-100W-Single-Output-Switching-Power-Supply-fig-1

Recommend Mounting

MEAN-WELL-LPV-100-100W-Single-Output-Switching-Power-Supply-fig-2

Block Diagram

MEAN-WELL-LPV-100-100W-Single-Output-Switching-Power-Supply-fig-3

Derating Curve

MEAN-WELL-LPV-100-100W-Single-Output-Switching-Power-Supply-fig-5

Static Characteristics

MEAN-WELL-LPV-100-100W-Single-Output-Switching-Power-Supply-fig-6