MEAN WELL DRA-60-12 Single Output Switching Power Supply
Feature
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Can be installed on DIN rail TS-35/7.5 or 15
- Output Voltage adjustable through internal potentiometer
- Output Current adjustable through external 1 ~1 0Vdc, PWM signal or resistance
- Cooling by free air convection
- Pass LPS
- LED indicator for power on
- 100% full load burn-in test
- 3 years warranty
Applications
- Machine vision inspection system
- Plant cultivation system
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
DRA-60 is one 60W AC/DC DIN rai l power supply, featuring the adjustable output current. Users are able to easi ly change the constant output current level, via 1 ~ 1 0Vdc, PWM signal or resistance. DRA-60 can be mounted on DIN rail TS-35/7.5 or 15; in addition, the width of the unit is only 40mm that it is well suited for the installation in a limited spacing. DRA-60 accepts the universal AC input between 90VAC and 264VAC; the efficiency is up to 87% that the entire series can operate, under free air convection , from -30°C through 70°C.
Model Encoding
SPECIFICATION
MODEL | DRA-60-12 | DRA-60-24 | |
OUTPUT | DC VOLTAGE | 12V | 24V |
CONSTANT CURRENT REGION | 3 ~ 12V | 3 ~ 24V | |
RATED CURRENT | 5A | 2.5A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 2.5A | |
RATED POWER | 60W | 60W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 12 ~ 15V | 24 ~ 30V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | |
SETUP, RISE TIME Note.4 | 400ms, 90ms/230VAC 800ms, 90ms/115VAC at full load | ||
HOLD UP TIME (Typ.) | 50ms/230VAC 10ms/115VAC at full load | ||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
EFFICIENCY (Typ.) | 85% | 87% | |
AC CURRENT (Typ.) | 1.3A/115VAC 0.8A/230VAC | ||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 60A/230VAC | ||
PROTECTION | OVERLOAD | 95 ~ 108% rated output power | |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 14.49 ~ 18.63V | 28.98 ~ 37.26V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) on output | ||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||
SAFETY & EMC (Note 5) | SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61204-3, light industry level, criteria A, EAC TP TC 020 | ||
OTHERS | MTBF | 2930.8K hrs min. Telcordia SR-332 (Bellcore) ; 436.4K hrs min. MIL-HDBK-217F (25℃) | |
DIMENSION | 40*90*100mm (W*H*D) | ||
PACKING | 0.3Kg; 42pcs/13.6Kg/0.82CUFT | ||
NOTE |
Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Block Diagram
Derating Curve
- AMBIENT TEMPERATURE (℃)
Static Characteristics
Output Current Adjustment Operation
- Built-in 3 in 1 current adjustment function . Output constant current level can be adjusted by applying 1 ~ 10Vdc, 10V PWM signal or resistance between DIM+ and DIM-.
- Please DO NOT connect “DIM-” to “-V”.
- Reference resistance value for output current adjustment (Typical)
Resistance value | Single Power supply | 10KΩ | 20KΩ | 30KΩ | 40KΩ | 50KΩ | 60KΩ | 70KΩ | 80KΩ | 90KΩ | 100KΩ | OPEN |
Multiple Power supplies (N=Power supply quantity for simultaneous current adjustment control) | 10KΩ/N | 20KΩ/N | 30KΩ/N | 40KΩ/N | 50KΩ/N | 60KΩ/N | 70KΩ/N | 80KΩ/N | 90KΩ/N | 100KΩ/N | —– | |
Percentage of rated current | 10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100% |
1 ~ 10Vdc for output current adjustment (Typical)
Applied Source | 1V | 2V | 3V | 4V | 5V | 6V | 7V | 8V | 9V | 10V | OPEN |
Percentage of rated current | 10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100% | 102%~108% |
10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
Duty value | 10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100% | OPEN |
Percentage of rated current | 10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100% | 102%~108% |
Using the current adjustment function can not adjust the output current to 0A. Please refer to the connection method below to adjust the output
current to 0A.
Driving Methods Of Applications
The power supply may either work in “constant voltage mode or constant current mode”
![]() |
In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. |
Mechanical Specification
Installation Instruction
- Back View
This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual.
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
User’s Manual
Documents / Resources
![]() |
MEAN WELL DRA-60-12 Single Output Switching Power Supply [pdf] Instruction Manual DRA-60-12 Single Output Switching Power Supply, DRA-60-12, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |