matt-E-logo

matt E ARD-6-32-R-SPD Three Phase Connection Unit

matt-E-ARD-6-32-R-SPD-Three-Phase-Connection-Unit-product

Specifications

  • Product Name: ARD-6-32-R-SPD
  • Description: Three-phase connection unit with auto rest isolator, Type 2 SPD, and 6 x 32A DP Type A RCBOs
  • Input Volts: 400V 50Hz 63amps
  • Cable Entry Facility: Top and bottom 25mm2
  • Terminal Capacity: Dimensions (H x W x D): 550mm x 360mm x 120mm
  • Weight: Approximately 7kg
  • Enclosure Ingress Protection: Mild Steel Powder Coated IP4X
  • Warranty: 1 Year

Product Usage Instructions

  1. Installation: Follow the provided installation guide to connect the unit properly to the power source.
  2. Usage: Ensure to switch on the auto rest isolator before using the unit for safety.
  3. Maintenance: Regularly check for any signs of wear or damage and contact customer service if needed.

Contact Information

  • T: 01543 227290 | E: info@matt-e.co.uk | W: www.matt-e.co.uk
  • matt:e Ltd, Unit 1 Langley Brook Business Park, Middleton, Tamworth B78 2BP …Simplifying EV connection

The matt:e ARD connection centres with unique 5 pole auto reset device and built in Type 2 SPD.

  • Simple to install, dedicated EV connection centres with built in O-PEN® technology that allows for the connection of EV charge points to the PME earthing facility without the use of earth electrodes.
  • Helping to facilitate compliance with BS:7671. 2018 Amendment 2, 2022 Regulation 722.411.4.1.(iii).

Product Features and benefits

  • Built in O-PEN® technology
  • NO EARTH ELECTRODES REQUIRED
  • Helps reduce disruptive and costly groundworks
  • Removes the risk of striking buried services
  • Simple wire in wire out connection
  • Complete with Type 2 SPD
  • With 6 x built in 32A Double Pole Type A RCBOs
  • Mild steel IP4X enclosure
  • Standard 1 Year parts warranty.

Product Overview

matt-E-ARD-6-32-R-SPD-Three-Phase-Connection-Unit-fig-1

Specifications

Specifications
Input Volts 400V 50Hz
Max Load 63amps
Cable Entry Facility Top and bottom
Terminal Capacity 25mm2
Dimensions ( H x W x D ) 550mm x 360mm x 120mm
Weight Approximately 7kG
Enclosure Mild Steel Powder Coated
Ingress Protection IP4X
Warranty 1 Year

FAQs

Q: How do I reset the auto rest isolator?
A: To reset the auto rest isolator, turn it off and then back on after a few seconds to clear any faults.

Q: What is the purpose of Type 2 SPD in the unit?
A: The Type 2 SPD (Surge Protection Device) is designed to protect against power surges and transient voltage spikes.

Documents / Resources

matt E ARD-6-32-R-SPD Three Phase Connection Unit [pdf] User Guide
ARD-6-32-R-SPD Three Phase Connection Unit, ARD-6-32-R-SPD, Three Phase Connection Unit, Connection Unit, Unit

References

Leave a comment