matt E ARD-6-32-M-SPD Three Phase Connection Unit

matt-E-ARD-6-32-M-SPD-Three-Phase-Connection-Unit-PRODUCT

Product Usage Instructions

Installation

  • Ensure power is switched off before installation.
  • Mount the ARD connection unit securely in a suitable location.
  • Connect the input cables to the designated terminals based on the provided specifications.
  • Route the load cables through the appropriate cable entry points.
  • Check all connections for tightness and secure the unit in place.

Operation

  • To operate the unit, ensure the isolator is in the ‘ON’ position.
  • In case of a fault or overload, the auto-reset device will activate as needed.
  • The Type 2 SPD provides additional surge protection for connected equipment.

Maintenance

  • Regularly inspect the unit for any signs of damage or wear.
  • Clean the enclosure as needed to prevent dust buildup.
  • If any issues arise, contact customer support for assistance.

FAQ

  • Q: What is the purpose of the auto-reset isolator?
    • A: The auto reset isolator helps to automatically disconnect power in case of a fault and then reconnect once the issue is resolved, providing added safety and convenience.
  • Q: How does the Type 2 SPD benefit my electrical system?
    • A: The Type 2 Surge Protection Device (SPD) helps protect connected devices from voltage spikes and surges, safeguarding them against potential damage.
  • Q: How can I ensure compliance with relevant regulations during installation?
    • A: Follow the provided specifications and guidelines, and if unsure, consult a qualified electrician to ensure proper installation and compliance with regulations such as BS:7671.

Introduction

  • The matt:e ARD connection centers with a unique 5 pole auto reset device and built-in Type 2 SPD.
  • Simple to install, dedicated EV connection centers with built-in O-PEN® technology that allows for the connection of EV charge points to the PME earthing facility without the use of earth electrodes.
  • Helping to facilitate compliance with BS:7671. 2018
  • Amendment 2, 2022 Regulation 722.411.4.1. (iii).

matt-E-ARD-6-32-M-SPD-Three-Phase-Connection-Unit-FIG-1

Product Features and Benefits

  • Built-in O-PEN® technology
  • NO EARTH ELECTRODES REQUIRED
  • Helps reduce disruptive and costly groundwork
  • Removes the risk of striking buried services
  • Simple wire-in-wire-in-wire-out connection
  • Complete with Type 2 SPD
  • With 6 x built-in 32A DP MCBs
  • Mild steel IP4X enclosure
  • Standard 1-year parts warranty.

matt-E-ARD-6-32-M-SPD-Three-Phase-Connection-Unit-FIG-2

Specifications

Input Volts 400V 50Hz
Max Load 63amps
Cable Entry Facility Top and bottom
Terminal Capacity 25mm2
Dimensions ( H x W x D ) 550mm x 360mm x 120mm
Weight Approximately 7kG
Enclosure Mild Steel Powder Coated
Ingress Protection IP4X
Warranty 1 Year