matt E ARD-6-32-M-SPD Three Phase Connection Unit
Product Usage Instructions
Installation
- Ensure power is switched off before installation.
- Mount the ARD connection unit securely in a suitable location.
- Connect the input cables to the designated terminals based on the provided specifications.
- Route the load cables through the appropriate cable entry points.
- Check all connections for tightness and secure the unit in place.
Operation
- To operate the unit, ensure the isolator is in the ‘ON’ position.
- In case of a fault or overload, the auto-reset device will activate as needed.
- The Type 2 SPD provides additional surge protection for connected equipment.
Maintenance
- Regularly inspect the unit for any signs of damage or wear.
- Clean the enclosure as needed to prevent dust buildup.
- If any issues arise, contact customer support for assistance.
FAQ
- Q: What is the purpose of the auto-reset isolator?
- A: The auto reset isolator helps to automatically disconnect power in case of a fault and then reconnect once the issue is resolved, providing added safety and convenience.
- Q: How does the Type 2 SPD benefit my electrical system?
- A: The Type 2 Surge Protection Device (SPD) helps protect connected devices from voltage spikes and surges, safeguarding them against potential damage.
- Q: How can I ensure compliance with relevant regulations during installation?
- A: Follow the provided specifications and guidelines, and if unsure, consult a qualified electrician to ensure proper installation and compliance with regulations such as BS:7671.
Introduction
- The matt:e ARD connection centers with a unique 5 pole auto reset device and built-in Type 2 SPD.
- Simple to install, dedicated EV connection centers with built-in O-PEN® technology that allows for the connection of EV charge points to the PME earthing facility without the use of earth electrodes.
- Helping to facilitate compliance with BS:7671. 2018
- Amendment 2, 2022 Regulation 722.411.4.1. (iii).
Product Features and Benefits
- Built-in O-PEN® technology
- NO EARTH ELECTRODES REQUIRED
- Helps reduce disruptive and costly groundwork
- Removes the risk of striking buried services
- Simple wire-in-wire-in-wire-out connection
- Complete with Type 2 SPD
- With 6 x built-in 32A DP MCBs
- Mild steel IP4X enclosure
- Standard 1-year parts warranty.
Specifications
Input Volts | 400V 50Hz |
Max Load | 63amps |
Cable Entry Facility | Top and bottom |
Terminal Capacity | 25mm2 |
Dimensions ( H x W x D ) | 550mm x 360mm x 120mm |
Weight | Approximately 7kG |
Enclosure | Mild Steel Powder Coated |
Ingress Protection | IP4X |
Warranty | 1 Year |