MASTER ELECTRIC MT-DP96FHMF Series Digital Clock Instructions

MT-DP96FHMF meter with high ability and precision. It’s can measures important electrical parameter as V, A, F, PF, P, Q, S, KWh, KVARh, KWh (-), KVARh(-), Total Harmonic Distortion (THD), Harmonic Distrortion from 2nd to 31st order, multi rate function…/
With integration RS-485 communication port, complete with each kinds intelligent distribute system and power energy manage system, share abundance monitor data/
FUNCTION INTRODUCE
Measure function
Remark
Realtime measure
Three phase voltage (L-L, L-N)
Three phase current and neutral current
System Frequence
P, Q, S, PF (per phase & total
Electric energry
KWh import
KVARh import
KWh export, KVARh export
Multi rate function/
Da ti gia
8 period/ 8 khoang theyi gian 4 kind of multi rate/ 4 ti gia
Harmonics/ Song hai
THDU per phase/ T6ng hai ap tren tang pha
THDI per phase/ Tong hai dung ten t&ng pha
HDI per phase from 2″d to 318′ order/ Hai clang ter bac 2-31 tren trung pha
HDU per phase from 2nd to 318′ order/ Hai ap ter bac 2-31 hen ti:rng pha
Communication/ Truyen than Maximen Demand Ngo ra analog Digital input/ Ng6 vao so Relay output
RS485 Port MODBUS-RTU
U,I,P,Q
Basic function
0-20mA/ 4-20mA/ 0-5V/ 0-10V
Dry contact type
AC250V 5A Remote
Expanded option
Display type
Measure function |
Remark |
Realtime measure |
Three phase voltage (L-L, L-N) |
Basic function |
Three phase current and neutral current |
System Frequence |
P, Q, S, PF (per phase & total |
Electric energry |
KWh import |
KVARh import |
KWh export, KVARh export |
Multi rate function |
8 period |
Harmonics |
THDU per phase |
THDI per phase |
HDI per phase from 2nd to 31st order |
HDU per phase from 2nd to 31st order |
Communication |
RS485 PortMODBUS-RTU |
Maximen Demand |
U,I,P,Q |
Analog output |
0-20mA |
Expanded option |
Digital input |
Dry contact type |
Relay output |
AC250V 5A Remote |
Display type |
Special display, LCDscreen |
TECHNICAL PARAMETER
|
Parameter |
Signal Inpu |
Connection system |
3P3W |
Voltage |
Measurementrange |
519V |
Over load |
Continous: 1.2 Vn; Instantaneous: 2Vn |
Powerconsumption |
< 1VA |
Current |
Measurementrange |
5A/ 1A |
Over load |
Continous: 1.2In; Instantaneous: 2In |
Powerconsumption |
< 1VA |
Frequence |
45 – 65Hz |
Auxiliary power suply |
AC 85-265V DC100-300V |
Communication |
RS485 communication port, physical layer isolation.According international standard MODBUS-RTU agreement. Communication speed 1200-38400 (Default 9600)Test type N81, E81, 081 (Default N81) |
Analog output |
0-20mA/ 4-20mA |
Relay output |
Programme remoteCapacity 5A at 250VAC |
Digital input |
Remote switch input signal, dry contact input. Programrelate alarm output |
Measure class |
Current/ VoltageFrequency/ Tan so: +0.1HzActive power Reactive powerEnergy |
IP protection |
IP53 for indoor type and PI65 for outdoor type |
Evernionment |
Working temperature -10+55°C Store temperatureRelative Humidity |
Safe |
Isolation: Signal, auxiliary power suply, output terminalcrust resistance >5MU and withstand voltage pulse>AC2KV |
Parameters |
MT-DP96FHMF |
MT-DP96HMF |
MT-DP96MF |
MT-DP96MFA |
MT-DP96V |
MT-DP96A |
Voltage |
 |
 |
 |
 |
 |
x |
Voltage |
 |
 |
 |
 |
 |
x |
Neutral voltage |
 |
 |
 |
 |
 |
x |
Line current |
 |
 |
 |
 |
x |
 |
Neutral current |
 |
 |
 |
 |
x |
 |
Average current |
 |
 |
 |
 |
x |
x |
|
 |
 |
 |
 |
x |
x |
Power factor |
 |
 |
 |
 |
x |
x |
Averga power factor |
 |
 |
 |
 |
x |
x |
Active Power |
 |
 |
 |
 |
x |
x |
Total active power |
 |
 |
 |
 |
x |
x |
Reactive power |
 |
 |
 |
 |
x |
x |
Total reactive power |
 |
 |
 |
 |
x |
x |
Apparent power (L1, L2, L3) |
 |
 |
 |
 |
x |
x |
Total apparent power |
 |
 |
 |
 |
x |
x |
Maximum voltage demand |
 |
x |
x |
x |
x |
x |
Maximum current demand |
 |
x |
x |
x |
x |
x |
Maximum power demand |
 |
x |
x |
x |
x |
x |
Maximum demand time |
 |
x |
x |
x |
x |
x |
Active import energy |
 |
 |
 |
 |
x |
x |
Active export energy |
 |
 |
 |
 |
x |
x |
Reactive import energy |
 |
 |
 |
 |
x |
x |
Reactive export energy |
 |
 |
 |
 |
x |
x |
Setting time (year, month,day, hour…) |
 |
 |
 |
 |
x |
x |
Multi rate function |
 |
 |
 |
 |
x |
x |
THD voltage (L1, L2, L3)/ |
 |
 |
x |
x |
x |
x |
THD current(L1, L2, L3) |
 |
 |
x |
x |
x |
x |
Voltage harmonics (2nd to 31 torder) |
 |
 |
x |
x |
x |
x |
Current harmonics (2nd to 31storder) |
 |
 |
x |
x |
x |
x |
Communication MOBUS RS-485 |
 |
 |
 |
 |
x |
x |
Active pulse |
 |
 |
 |
 |
x |
x |
Reactive pulse |
 |
 |
 |
 |
x |
x |
Digital input |
Option |
Option |
Option |
Option |
Option |
Option |
Relay output |
Option |
Option |
Option |
Option |
Option |
Option |
Analog output |
Option |
Option |
Option |
Option |
Option |
Option |
DIMENSION

Model |
LxH (mm) |
AxB (mm) |
SxY (mm) |
SxY (mm)IP65 |
N (mm) |
M(mm) |
MT-DP96VMT-DP96A MT-DP96MFA MT-DP96MF MT-DP96HMFMT-DP96FHMF |
96×96 |
90.5×90.5 |
91×91 |
91.5×91.5 |
94 |
88 |
MT-DP72VMT-DP72A MT-DP72MFA MT-DP72MF MT-DP72HMFMT-DP72FHMF |
72×72 |
65.6×65.6 |
66×66 |
67×67 |
97 |
91 |
MT-DP48VMT-DP48A MT-DP48MAF |
48×48 |
44×44 |
45×45 |
|
90 |
84 |
MT-DP49VMT-DP49A MT-DP49MAF |
48×96 |
43.2×90.2 |
43.5×90.5 |
|
95 |
89 |
CONNECTION




Active Pulse |
Reactive Pulse |
|
RS485 |
|
Aux. PowerSuply |
Ep- |
Ep+ |
Ep- |
Ep+ |
|
B |
A |
|
N(V-) |
L(V+) |
48 |
47 |
50 |
49 |
|
59 |
58 |
|
2 |
1 |
Relay Output |
Digital input |
Analog output |
DO1 |
DO2 |
DO3 |
DO4 |
COM |
DI1 |
DI2 |
DI3 |
DI4 |
A0- |
A01+ |
A02+ |
A03+ |
A04+ |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
70 |
71 |
72 |
73 |
74 |
30 |
31 |
32 |
33 |
34 |
Documents / Resources