marsdelivers 50321 Control Transformers Power Transformers
Specifications
MARS Control Transformers NEMA Class II Manual Reset Style
- Available outputs and voltages for special applications
- Application: Provide power source for control circuit for air conditioning, heating, or refrigeration systems
MARS Power Transformers
- Provide 120V power source for air conditioning, heating, or refrigeration systems
- Dual purpose options: 120V or 24V secondary with 208V/240V/480V primary connections
- Three VA selections available
GE Type Ip Core and Coil Transformers
- Core and coil units designed for industrial control, panel board, HVAC, and general purpose applications
- Conform to ANSI C89.2, UL listed, and CSA certified
- Lightweight, small, and designed for minimum mounting dimensions
Product Usage Instructions
MARS Control Transformers
- Identify the specific model number based on your voltage and output requirements.
- Connect the primary and secondary voltage leads following the color-coded connections provided.
- Mount the transformer securely in a suitable location.
MARS Power Transformers
- Choose between the 120V or 24V secondary option based on your application needs.
- Connect the primary voltage leads (208V/240V/480V) as required.
- Use color-coded leads for easy connection of secondary voltage.
GE Type Ip Core and Coil Transformers
- Select the appropriate model based on your power requirements.
- Connect primary and secondary voltage leads following the provided specifications.
- Ensure proper mounting to meet minimum dimensions and safety requirements.
FAQ
- Q: Can I use a higher VA rating for the MARS Control Transformers?
A: VA ratings above 100 do not qualify for NEMA Class II specifications. - Q: Are the GE Type Ip Core and Coil Transformers suitable for HVAC applications?
A: Yes, GE Type Ip transformers are designed for HVAC applications among others.
MARS Control Transformers NEMA Class II Manual Reset Style
MARS control transformers are available with various outputs and voltages for special applications.
Application:
Provide power source for control circuit for air conditioning, heating, or refrigeration systems.
Features:
- UL class 2 recognized
- Low heat rise
- Color coded leads or quick connect terminals
- Foot-mount
Foot-Mount End Bell Type with Manual Reset
MARS NO. | VA RATING | HZ | PRIMARY VOLTAGE CONNECTIONS |
SECONDARY VOLTAGE CONNECTIONS |
||
50327 | 50 | 60 | 120/208/ 240/480 | Color coded leads | 24 | Color coded leads |
50321 | 75 | 50/60 | 120/208/ 240/480 | Color coded leads | 24 | Color coded leads |
50375 | 75 | 50/60 | 120/208/ 240/575 | Color coded leads | 24 | Color coded leads |
50341* | 100 | 50/60 | 120/208/240/480 | Color coded leads | 24 | Color coded leads |
50312 | 60 | 50/60 | 120/208/240/480 | Color coded leads | 24 | Color coded leads |
50370 | 75 | 50/60 | 120/277/380/575 | Color coded leads | 24 | Color coded leads |
50371 | 100 | 50/60 | 120/208/277/575 | Color coded leads | 24 | Color coded leads |
* 100VA and higher does not qualify for NEMA Class II
MARS Power Transformers
Application:
Provide 120V power source for air conditioning, heating, or refrigeration systems. MARS power transformers provide dual purpose options — 120V or 24V secondary with 208V/240V/480V primary connections. Three VA selections offer a true powerhouse!
Features:
- Color coded leads
- Compact size
- Low heat rise
Power Transformers Foot-Mount Open Construction
MARS NO. | VA RATING | HZ | VOLTAGE | PRIMARYCONNECTIONS | SECONDARY VOLTAGE CONNECTIONS |
|
50380(1) | 50 | 60 | 208/240/480 | Color coded leads | 120/24 | Color coded leads |
50381(2) | 100 | 60 | 208/240/480 | Color coded leads | 120/24 | Color coded leads |
- Not UL listed
- UL 506
GE Type Ip Core and Coil Transformers
GE type IP transformers are core and coil units designed for industrial control, panel board, HVAC and general purpose applications. They conform to ANSI C89.2, and are UL listed and CSA certified. These transformers are lightweight, small and designed for minimum mounting dimensions.
Features:
- 60 Hz
- Encapsulated thru 500VA
- Control power applications
- UL listed, UL-506 File E2739
- CSA certified, C22.2 Number 66, File 3272
- 50 Hz available on special order basis
Encapsulated Style Views
Encapsulated
MARS NO. | CONT. KVA | PRIMARY | SECONDARY | A | B | DIMENSIONS C | D | E |
50502 | .075 | 240/480 | 120/240 | 4.22 | 3.29 | 2.79 | 2.41 | 2.50 |
50504 | .150 | 240/480 | 120/240 | 4.67 | 4.04 | 3.29 | 2.66 | 3.12 |
50506 | .250 | 240/480 | 120/240 | 5.17 | 4.04 | 3.29 | 3.16 | 3.12 |
50507 | .300 | 240/480 | 120/240 | 5.17 | 4.04 | 3.29 | 3.16 | 3.12 |
- Toll Free 800-445-4155
- Fax 631-348-7160
- www.marsdelivers.com
WARNING:
Cancer and Reproductive Harm www.P65Warnings.ca.gov
Documents / Resources
![]() |
marsdelivers 50321 Control Transformers Power Transformers [pdf] Owner's Manual 50321, 50327, 50375, 50341, 50312, 50370, 50371, 50380, 50381, 50502, 50504, 50506, 50321 Control Transformers Power Transformers, 50321, Control Transformers Power Transformers, Transformers Power Transformers, Power Transformers, Transformers |