Marinfloc CD Units Owner’s Manual

Marinfloc-logo

Marinfloc CD Units

Marinfloc-CD-Units-product-image

Specifications

  • Service Bulletin no.: 10
  • Date: 2006-02-13
  • System Applicability: Marinfloc CD units

Introduction

The CD unit, trusted by over 700 vessels worldwide, is a state-of-the-art dissolved air flotation and flocculation system available in capacities ranging from 0.25 to 5.0 m³/h. It consistently treats bilge water to levels below 5 ppm. Equipped with an intuitive HMI screen, it empowers the crew with the right tools to tackle all variations of bilge water. Operators can easily adjust the dosage to meet varying bilge water compositions. Designed specifically for onboard conditions, not only does the CD unit comply with MARPOL requirement MEPC.107(49), but it also boasts the lowest OPEX in the market.

Primary advantages

  • Utilizes flocculation technology, eliminating the need for cartridge filters and centrifuges.
  • Adaptable to treat the specific composition of a ship’s bilge water.
  • Type-approved to 5 ppm.
  • Easy to install, easy to retrofit.
  • Designed for low energy consumption, contributing to reduced carbon footprints.
  • Touchscreen control cabinet available for smart functions and online connectivity.
  • Offers a low operational cost, ensuring value for money.

Water treatment methods

Flocculation
Flocculation is a water treatment process in which solids come together to form larger clusters, or flocs, which are then removed from the water. This process can occur naturally or with the assistance of chemical agents. It is a common method of wastewater treatment and drinking water purification. The process of flocculation is chemical in nature. It entails sequentially adding chemicals to the wastewater and allowing tiny solid particles to aggregate into a larger particle that can be separated from water. The treatment of wastewater by flocculation is done in stages. Solid particles suspended in wastewater are negatively charged. A coagulant, such as aluminum chloride, is added to the wastewater. The negatively charged solid particles suspended in the water are neutralized by the positively charged coagulant molecules. The neutralization of these particles allows them to flocculate together into a larger particle. A polymer chemical is added to the wastewater once flocs begin to form. Polymers link the flocculant from micro to macro flocculant, increasing the mass of particles clumping together. This chemical also binds the collected mass together, preventing it from dissolving even when the water is slightly agitated.

Dissolved air flotation
Dissolved air flotation (DAF) is a water treatment method that removes suspended particles such as oil or sediments from wastewaters or other liquids. The separation is accomplished by dissolving air under pressure in the water or wastewater and then releasing the air at atmospheric pressure in a flotation tank. The released air forms tiny bubbles that cling to the suspended matter, causing it to float to the surface where it can be removed. This technique is widely used in land based industrial wastewater treatment units for oil refineries, paper mills, general water treatment plants, and other industrial facilities. Water being fed to the DAF tank is dosed with a flocculant to bind the particles into bigger clusters. For the Marinfloc CD, this is achieved in stages 2 and 3.Marinfloc-CD-Units-image-2

 

Options and sizes

  • One unit or divided
  • The CD unit can be delivered as one unit or divided in two modules for easier retrofit installations.

Sizes
The CD unit is available in the following capacities:

  • 0.25 m³/hour
  • 1.0 m³/hour
  •  2.0 m³/hour
  • 5.0 m³/hour

Marinfloc-CD-Units-image-3

Option: WhiteBox®
The Marinfloc WhiteBox® System is a fail-safe system for the overboard discharge of water. The WhiteBox® is designed so that no water with an oil content above the set limit can accidentally be pumped overboard. The oily water separator discharge pump feeds water through the WhiteBox® system. An adequate flow of water is continuously directed to the oil content meter by the differential pressure valve. The sample is measured by the oil content meter after being directed through the flow switch. The purpose of the flow switch is to secure that no bilge water can be discharged overboard without first being measured by the oil content meter. The flow through the flow meter, the oil content, the position of the three-way valve, status OCM is activated, the status of the system (on/off), the time and the ship’s GPS position (optional) will be logged on the recorder and stored on an external memory card.Marinfloc-CD-Units-image-4

Operating principle

The Marinfloc system is a fully automatic bilge water cleaning system, based on flocculation. The system can handle stable chemical emulsions and was the first system approved to IMO resolution MEPC.107(49). It is also certified by U.S. Coast Guard and all major classification societies. The CD-system is type-approved in accordance with DNV 5 ppm type approval program. The drain separator’s operation can be broken down into four steps:Marinfloc-CD-Units-image-5

  1. Oil separation
    The feed pump (1) channels bilge water from a strainer (66) to the oil descale (44). Utilizing gravimetrical principles, this stage effectively separates free oil from water. When oil accumulates in the top section, the oil sensor (39) activates, prompting the transfer of oil to the vessel’s sludge tank.
  2. Aeration
    When the water level in the circulating tank reaches high level, compressed air is added to the tank to aerate the water. A pump circulates air and water to increase the surface area of the water for maximum dissolvent of
    air into the water. The bilge water will continuously be discharged out of the circulation tank and the feed pump will compensate accordingly.
  3. Flocculation and forced flotation
    Aerated water flows from the circulation tank to the flocculation tank (87). Here, the flow and dosage of flocculent chemicals are meticulously controlled. Two dosage pumps (2A, 2B), one for the flocculent chemical and the other for the Flocbooster, ensure precise chemical injection into the bilge water.
    The flocculation tank, comprising three chambers, facilitates separation of floating flocks and water, with a foam layer forming on top. This foam layer is continuously drained to the sludge tank by the drain pump (9).
  4. Filtration
    Post-flocculation, the water, potentially slightly discolored or turbid, passes through three filters to achieve an effluent quality of <15 ppm. The first filter contains an oil-absorbing mineral material, capturing any remaining oil and flocks. The subsequent filters are filled with activated carbon, removing discoloration and any residual flocks. All filters are underlaid with coarse sand to prevent clogging of the back-flush water pipe slits. These filters can be back-flushed manually or automatically using heated water. Owing to the high efficiency of the flocculation stage, the filter material has an extended lifespan and can be regenerated on-site with steam.
  5. Oil content meter (OCM)
    The oil content meter (15A) ensures compliance with environmental regulations by verifying that the water’s oil content does not exceed the set limit, typically 15 or 5 ppm. The system incorporates a flow switch (96) on the sample line, which prevents discharge if the oil content meter’s sample valve is closed or if there isn’t sufficient flow for an accurate sample.
  6. Temperature
    The ideal process temperature is 45-55 °C. If the temperature is too low, the bilge water will not enter the flocculation tank; it will be discharged back to the bilge water holding tank until the right temperature is obtained.

Marinfloc-CD-Units-image-6

Technical data

CD 0.25 CD 1.0 CD 2.0 CD 5.0
Capacity of treated bilge water max. 250 liters/h max. 1 000 liters/h max. 2 000 liters/h max. 5 000 liters/h
Operating temperature of bilge water * Optimal: +50 °C; Min. +40 °C; Max. +60 °C
Operating pressure 0.25–0.40 MPa / 2.5–4.0 bar
Test pressure 0.78 MPa / 7.8 bar
Safety valves release 0.60 MPa / 6.0 bar
Voltage supply 3 x 400–690V, AC, 50–60 Hz
Electric power consumption /

Fuse

1.6 kW / 10 A 2.3 kW / 10 A 2.56 kW / 10 A 4.5 kW / 10 A
IP-classification IP 54
General service air pressure 0.6–0.9 MPa / 6.0–9.0 bar
General service air consumption <2 normal liters/sec. <5 normal liters/sec. <9 normal liters/sec. <23 normal liters/sec.
Technical water pressure 0.3–0.6 MPa / 3.0–6.0 bar
Back-flushing cycle, fresh- water consumption/full cycle approx. 60 liters approx. 200 liters approx. 300 liters approx. 750 liters
Filter stages, each 20 liters/filter, AISI 316L 65 liters/filter, AISI 316L 100 liters/filter, AISI 316L 250 liters/filter, AISI 316L
Total net weight incl. filter media (dry) 430 kg 968 kg 1 475 kg 2 100 kg
Total operating weight (wet) 630 kg 1 450 kg 2 160 kg 3 960 kg
Main dimensions (W x D x H) 1200 x 800 x 1500 mm 1700 x 1100 x 1700 mm 2000 x 1250 x 2000 mm 2800 x 1800 x 2150 mm
  • Disclaimer on inlet water temperature: Bilge water must be supplied at 50–55 °C. Heating is the responsibility of the client unless otherwise agreed in our scope.Marinfloc-CD-Units-image-7

Flowchart

Pos. Denomination Pos. Denomination Pos. Denomination
1 Feed pump 9 Drain pump 96 Flow switch indicator
2 Dosage pumps 10 Backflush filter no. 1 117 Excessive flow
3 High level flocculation tank 11 Backflush filter no. 2 130 Low level circulation tank
4 Circulation pump 12 Backflush filter no. 3 131 High level circulation tank
5 Discharge pump 15 Oil content meter alarm 133 Air inlet circulation tank
6 Cleaned water outlet 21 Oil release 135 Regulating inlet velvet
7 Bilge water return 45 High filter pressure 139 Recirculating valve
8 Low level flocculation tank 58 Cold/hot bilge water return 140 Filtering valve

Marinfloc-CD-Units-image-9

Contact Information

Documents / Resources

PDF thumbnailCD Units
Owner's Manual · SB 10, SB 13, SB 12, SB 11, CD Units

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.