eliteCLEAR Series Cartridge Filter
“
Product Information
Specifications
- Models: EliteCLEAR 150, EliteCLEAR 200
- Designed for swimming pool filtration
- High-pressure operation
Product Overview
The Cartridge Filters EliteCLEAR 150 and EliteCLEAR 200 are
designed to provide safe and reliable operation for swimming pool
filtration. It is essential to follow the installation and
operation instructions provided in the manual to ensure proper
functioning and longevity of the product.
Dimensions
The exact dimensions of the Cartridge Filters are not mentioned
in this manual. Please refer to the specific product documentation
for detailed dimensions.
Installation
Follow the detailed installation instructions provided in the
manual for setting up the Cartridge Filters. Failure to install the
filters correctly may result in operational issues.
Starting the Pump and Filter System
Before starting the pump, ensure you have followed all safety
precautions and guidelines outlined in the manual. Starting and
operating the pump correctly is crucial for efficient
filtration.
Maintaining Your Filter
- Filter Disassembly Instruction: Follow the
steps outlined in the manual to disassemble the filter for
maintenance. - Removing the Cartridge: Carefully remove the
cartridge according to the provided instructions. - Cleaning the Cartridge: Thoroughly clean the
cartridge to ensure optimal filtration performance. - Filter Reassembly Instruction: Reassemble the
filter components following the provided guidelines. - Removing the Air Relief Valve: Instructions
for removing and reinstalling the air relief valve are provided in
the manual.
Winterizing Filter
Prepare your filter for winter by following the winterizing
instructions to prevent damage during colder months.
Troubleshooting
Refer to the troubleshooting section in the manual to address
any operational issues that may arise during use.
Spare Part List
Refer to the spare part list provided in the manual for
information on replacement parts if needed.
Terms of Warranty
Review the terms of the warranty to understand coverage and
conditions for product support.
Frequently Asked Questions (FAQ)
Q: What should I do if I notice a decrease in filtration
efficiency?
A: If you experience decreased filtration
efficiency, check if the cartridge needs cleaning or replacement.
Follow the maintenance instructions for optimal performance.
“`
Cartridge Filters
EliteCLEAR 150
EliteCLEAR 200
INSTALLATION MANUAL
CARTRIDGE FILTERS
1
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
3
1 OVERVIEW
5
1.1 Product Information
1.2 Dimensions
2 INSTALLATION
4
3 STARTING THE PUMP AND FILTER SYSTEM
6
3.1 Before Starting the Pump
3.2 Starting the Pump
3.3 Operation
4 MAINTAINING YOUR FILTER
6
4.1 Filter Disassembly Instruction
4.2 Removing the Cartridge
4.3 Cleaning the Cartridge
4.4 Filter Reassembly Instruction
4.4.1 Re-installing the Cartridge
4.4.2 Removing the Cartridge
4.4.3 Cleaning the Cartridge
4.4.4 Filter Reassembly Instruction
4.5 Removing the Air Relief Valve
4.5.1 Re-installation of the Air Relief Valve
5 WINTERIZING FILTER
8
6 TROUBLESHOOTING
8
6.1 Water Chemistry
7 SPARE PART LIST
9
8 TERMS OF THE WARRANTY
10
2
IMPORTANT SAFETY INSTRUCTIONS
THESE OPERATING INSTRUCTIONS CONTAIN IMPORTANT INFORMATION ON THE SAFE, PROPER, AND ECONOMICAL OPERATION OF THIS SWIMMING POOL APPLIANCE. STRICT OBSERVATION OF THE OPERATING INSTRUCTIONS WILL HELP TO AVOID DANGERS, REDUCE REPAIR COSTS, AND SHUTDOWN TIMES AND INCREASE THE RELIABILITY AND WORKING LIFE OF THE PRODUCT.
Failure to follow the instructions in this manual may result in serious adverse health effects or even serious or fatal injury. Failure to follow the instructions iv this manual will in all cases invalidate all guarantees and liability on the part of the manufacturer.
Consumer Information and Safety These Cartridge Filters are designed and manufactured to provide years of safe and reliable operation. Operated and maintained according to the information in this manual and the installation codes referred to in later sections.
THIS FILTER OPERATES UNDER HIGH PRESSURE
When any part of the circulating system, (e.g., closure, pump, filter, valve(s), etc.), is serviced, air can enter the system and become pressurized. Pressurized air can cause the top closure to separate which can result in severe injury, death, or property damage. To avoid this potential hazard, follow these instructions:
1. If you are not familiar with your pool filtering system: (1) Do NOT attempt to adjust or service without consulting your dealer, or a qualified pool technician. (2) Read the entire Installation & Operation Manual before attempting to use, service, or adjust the pool filtering system.
2. Before repositioning valve(s) and before beginning the assembly, disassembly, or any other service of the circulating system: (1) Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing; (2) Open the air relief valve; (3) Wait until all pressure is relieved.
3. Whenever installing the filter closure follow the filter closure warnings exactly.
CARTRIDGE FILTERS
3
4. Once service on the circulating system is complete follow initial start-up instructions exactly.
5. Maintain circulation system properly. Replace worn or damaged parts immediately, (e.g., closure, pressure gauge, valve(s), O-rings, etc.).
6. Be sure that the filter is properly mounted and positioned according to the instructions provided.
This filter must be installed by licensed or certified electrician or qualified pool serviceman in accordance with the Local Code and all applicable local codes and ordinances. Improper installation could result in death or serious injury to pool users, installers, or others and may also cause damage to property. Always disconnect power to the pool circulating system at the circuit breaker before servicing the filter. Ensure that the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the filter. Failure to do so could result in serious injury or death to a serviceman, pool user, or others due to electric shock.
READ UNDERSTAND AND FOLLOW ALL SAFETY AND OPERATION:
Do not operate the filter until you have read and understand clearly all the operating instructions and warning messages for all equipment that is a part of the pool circulating system. The following instructions are intended as a guide for initially operating the filter in a general pool installation. Failure to follow all operating instructions and warning messages can result in property damage or severe personal injury or death.
To reduce the risk of injury, do not permit children to use this product.
ELECTROCUTION HAZARD
Direct water discharge from air relief valve away from electrical service. Do not locate pump control over near the filter.
Due to the potential risk that can be involved, it is recommended that the pressure test be kept to the minimum time required by the local code. Do not allow people to work around the system when the circulation system is under the pressure test. Post appropriate
4
warning signs and establish a barrier around the pressurized equipment. If the equipment is located in an equipment room, lock the door and post a warning sign. Never attempt to adjust any closures or lids or attempt to remove or tighten bolts when the system is pressurized. These actions can cause the closure to separate and could cause severe personal injury or death if they were to strike a person.
Never exceed the maximum operating pressure of system components. Exceeding these limits could result in a component failing under pressure. This instantaneous release of energy can cause the closure to separate and could cause severe personal injury or death if they were to strike a person.
HYPERTHERMIA
SPA water temperature excess of 38°C (104°F) may be injurious to health. Measure water temperature before entering SPA to strike a person.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6 °F (37 °C). The symptoms of hyperthermia include drowsiness, lethargy, and an increase in the internal temperature of the body.
CARTRIDGE FILTERS
5
1 OVERVIEW
The Madimack EliteCLEAR series cartridge filter combines superior water filtration with ease of operation and corrosion-free construction. With filtration ratings of 379 ~ 455 LPM / 100 ~120 GPM, they are designed for continuous or intermittent operation, for installation above or below the pool waterline, for fresh or saltwater swimming pools or spas. The Madimack EliteCLEAR series filters utilize multiple reusable, reinforced polyester filter cartridge elements to provide a high degree of water clarity and long filter cycles with minimum care.
1.1 Product Information
Model
EFFECTIVE FILTRATION ARIEA
FT2
M2
DESIGN FLOW RATE
Residential
Commercial
GPM
LPM
EliteCLEAR 150
150
13.94
120
455
EliteCLEAR 200
200
18.58
120
455
* Filter rate for residential use based on 1GPM/ft². Recommend Flow Rate for 2″ piping is 90 x 150 GPM
1.2 Dimensions
Model
A
B
C
D
IN CM IN CM IN CM IN CM
EliteCLEAR 150 20.9 53.05 12.40 31.50 18.30 46.40 3.20 8.20
EliteCLEAR 200 20.9 53.05 17.24 43.80 18.30 46.40 3.20 8.20
6
2 INSTALLATION
This product should be installed and serviced only by qualified pool professional. 1. The filter system should be installed on a level concrete slab or another
rigid base. Select a well-drained and vented area, that does not flood when it rains. Position the filter so that the piping connections and winter drain are convenient and accessible for operation, service, maintenance, and winterizing. 2. Position filter body such that all operation and safety labels are visible. 3. Position the filter so the filter will drain by gravity. 4. If practical, place the pump and filter in the shade to shield it from direct sunlight. 5. Connect the pool suction plumbing between the skimmer, the pool outlet (from the pool), and the pump. 6. Install the plumbing from the filter to the pool (return to the pool) 7. Do not locate pump controls over or near the filter. 8. Verify water discharge from the manual air Relief valve is directed away from electrical devices.
Model
REQUIRED CLEARANCE
A
“B” Sides “C” Above
“D”
IN CM IN CM IN CM IN CM
EliteCLEAR 150 36 91.2 18.3 46.4 18 45 18.30 46.40
EliteCLEAR 200 40.7 103.4 18.3 46.4 18 45 18.30 46.40
CARTRIDGE FILTERS
7
3 STARTING THE PUMP AND FILTER SYSTEM
3.1 Before Starting the Pump 1. Use ONLY ELITECLEAR system components: Lock Ring unit doing
assembly, metal-reinforced seal. Non-tighten lock ring component may fail in use and cause explosive component separation. Verify that upper and lower filter bodies are properly secured with the filter body locking ring unit. Make sure tightening enough the Lock Ring to the filter’s upper and bottom body. Verify that the filter manual air relief valve is in the LOCK position, and no filter components are missing, damaged, or not genuine EliteCLEAR filter components.
2. Close filter drain. Note: Drain plug requires an O ring seal.
Sealing O-ring Drain Plug
Figure 2
3. Open all system valves to allow water from the pool to the filtration system and from the filter to return to the pool.
8
4. Place the air relief valve in an OPEN position.
Air relief valve in an open position
Figure 3
3.2 Starting the Pump
Stand clear of pump during start-up
Pool and spa circulation systems operate under high pressure. When any part of the circulating system (i.e. lock ring, pump, filter, valves, etc.) is serviced, air can enter the system and become pressurized. Filter tank Lid and pre-filter cover must be secured to prevent violent separation. Place the pre-filter / filter air relief valve in an open position and wait for all pressure in the system to be relieved before removing the lib from access to the basket for cleaning.
When starting the system pump, do not stand over or near the filter. If water leakage appears at the lock ring. Turn off all system circulation pumps and all electrical power immediately. Do not return to the filter until all water leakage has stopped. Only return to filter to close air relief valve when water came out.
CARTRIDGE FILTERS
9
3.3 Operation
Filtration starts as soon as the flow is steady through the filter. As the filter removes dirt from the pool water, the accumulated dirt causes a resistance to flow. As a result, the pressure will rise and the flow will decrease.
1. Record the initial starting pressure which is the initial pressure reading when a new filter element is working under filtration conditions.
2. Every time after reinstalling “new filter element” or “after cleaned filter cartridge element”, make sure the system is under filtration condition, then turn the START arrow to the pressure gauge pointer position to indicate the Start pressure.
3. Monitor the pressure from time to time, when the pressure reading is over the Clean Filter arrow, follow step 4.2 to clean filter cartridge elements.
Figure 4
Replace a new filter cartridge element. You should replace a new filter cartridge element: 1. After cleaning the filter element, if the pressure is:
a.25 psi higher than the initial start ready, or b.the pressure reading is over 40 psi. 2. When the filter element is broken, or the layer peers off. 3. When the pressure or flow rate is below the desired rate of the system.
10
4 MAINTAINING YOUR FILTER
4.1 Filter Disassembly Instruction
1. Turn off all system circulation pumps and all electrical power on the equipment pad.
2. Set all system valves in a position to prevent water from flowing to the filter.
3. Turn the air relief valve OPEN. 4. Remove the filter drain plug, and water flows out from the filter. 5. Depress the latch and unscrew the lock ring (counterclockwise). 6. Liftoff filter upper body with the attached lock ring. Do not hold the
pressure gauge to lift the upper body. 7. Lift out the cartridge element.
4.2 Removing the Cartridge
1. Remove the filter cartridge element by using a slight rocking motion and lifting.
2. Clean filter cartridge element.
4.3 Cleaning the Cartridge
The cartridge filter element can be washed inside and outside by a garden hose. After hosing the cartridge, for best results, carefully brush the pleated surface to remove fine particles. Do not use high-pressure water to wash as it can damage the filter element. You may find some debris on the cartridge pleats, which may not have been removed with hosing.
4.4 Filter Reassembly Instruction
4.4.1 Filter Reassembly Instruction
1. Flush and drain any dirt or debris from the bottom of the lower filter body.
2. Flush any dirt or debris from the upper filter body and from around the air release area.
3. Carefully replace the cartridge over the hubs on the bottom manifold. 4. Place the upper body securely on top of the cartridge.
CARTRIDGE FILTERS
11
4.4.2 Clean Seal Ring and Seal Surface
1. Remove filter tank sealing O-ring. 2. With a clean cloth, wipe the lower filter body seal surface and clean
seal of all dirt and debris. Do not use any solvent. 3. With a clean cloth wipe the upper body seal surface.
Cartridge element Sealing O-ring Bottom body
4.4.3 Body and Lock Ring Re-assembly 1. Place the sealing O-ring on the bottom body. Place the upper body
on the O-ring and the bottom body. 2. Use the Madimack lock ring system only, tighten the lock ring
(clockwise) until the latch is locked on position. 3. Ensure that upper and bottom bodies are properly secured with the
lock ring.
NOTE: DO NOT HIT OR STRIKE THE CLAMP WITH A HAMMER OR METAL TOOLS. 4. Ensure that the air relief valve assembly is in an OPEN position and
no components are damaged or missing. 5. Ensure the drain plug is closed. 6. Open all system valves to allow water from the pool to the filtration
system and from the filter to the pool. 7. Wait for the water to come out from the air relief valve then turn the
air relief valve to fully CLOSE .
12
Lock ring Cartridge element
Upper body
Sealing O-ring Bottom body
Figure 6
4.4.4 Vacuuming Pool
Vacuuming can be performed directly into the filter whenever needed. Clean cartridge after vacuuming if required.
4.5 Removing the Air Relief Valve
The filter comes with a preinstalled manual air relief valve. Ser vicing the Air Relief Valve should be carried out by pool professionals only, follow instructions carefully: 1. Turn off all system circulation pumps and all-electric power on the
equipment pad. 2. Set all system valves in a position to prevent water from flowing to
the filter. 3. The air relief valve must be placed in the OPEN position. 4. Wait until all water leakage has stopped. 5. Grasp the Relief valve Nut at the release position, and turn the Nut
counterclockwise until the Air gauge indicator is on the “0” position on the upper filter body. 6. Keep on turning the Nut of the release valve until it leaves the Upper filter body.
CARTRIDGE FILTERS
13
4.5.1 Re-installation of the Air Relief Valve 1. Check the condition of the O-ring, replace it as necessary 2. With a clean cloth, wipe the upper filter body and O-ring groove.
Remove all dirt and debris. 3. Twist the air relief valve with the tool until it’s tightened on top of
the upper filter body. 4. Make sure the nut of the Release valve is tight. 5. Verify the air relief valve discharge points away from all electrical
connections.
5 WINTERIZING FILTER
In areas where sub-freezing temperatures can be expected, the filter should be drained to protect the filter from damage. 1. Follow the steps in “Filter disassemble instruction” to remove and clean
the cartridge. 2. Reinstall the cartridge in the filter. 3. Fully tighten the lock ring while storing. 4. Reassemble per FILTER REASSEMBLY INSTRUCTION. 5. Be sure to leave the drain plug unattached during the winter season to
avoid cracking the filter body.
14
6 TROUBLESHOOTING
Remedy
Low Water Flow SHORT FILTER CYCLES POOL WATER REMAINS CLOUDY
1. Check skimmer and pump strainer baskets for debris. 2. Check for restrictions in intake and discharge lines. 3 Check for air leak in intake line indicated by bubbles returning to pool. 4. Clean Filter Cartridges
1. Check for algae in the pool and superchlorinate as required. 2. Be sure chlorine and pH levels are in a proper range (adjust as required).
1. Check chlorine, pH, and total alkalinity levels and adjust as required. 2. Be sure the flow rate through the filter is sufficient. 3. Operate filter for longer periods.
6.1 Water Chemistry
SUGGESTED POOL CHEMISTRY LEVELS
pH LEVEL TOTAL ALKALINITY CALCIUM HARDNESS COMBINED CHLORINE CHLORINE (STABILIZED) CHLORINE STABILIZER (Cyanuric Acid)
7.2 to 7.8 80 to 120 ppm 200 to 400 ppm 0.2 ppm Maximum 1.0 to 3.0 ppm 60 to 80 ppm
CARTRIDGE FILTERS
15
7 SPARE PARTS LIST
Key No. Part No.
Description
QTY
1 117068519 Pressure gauge 60psi, plastic casing
1
2 550188199 Upper Body EliteCLEAR 150
1
2 550188200 Upper Body EliteCLEAR 200
1
3 570818164 Nut D22X15
1
4 550058153 Lock Ring
1
5 550058196 Latch
1
6 11000036 O-ring D306Xd7.5
1
7 430178159 Union nut 2″
2
8 430308158 Union 2inch/2.5inch ANSI
2
8 430309780 Union 1.5inch/2inch
2
8 430309779 Union GB50
2
8 430309059 Union GB63
2
9 111040071 O-ring D77Xd62X8
2
10 E140401
EliteCLEAR 150-200 Bottom Body
1
11 E160553
End cap with O-ring
1
12 E010201
Air Relief Valve with O-ring
1
13 570818165 Nut D31X20 14G
1
14 914100005 EliteCLEAR 150 Element
1
14 914100006 EliteCLEAR 200 Element
1
15 107048520 PVC Pipe 2.5inch for EliteCLEAR 150, 440mm
1
15 107048520 PVC Pipe 2.5inch for EliteCLEAR 200, 517mm
1
16 550128166 EliteCLEAR 150-200 Center Drain connection
1
16
8 TERMS OF WARRANTY
As the original purchaser of this equipment, acquired from Madimack through an authorized distributor or dealer, you are entitled to a warranty that guarantees the product is free from defects in materials and workmanship under normal use during the warranty period.
The warranty begins on the date of purchase and applies exclusively to the original purchaser. This warranty is non-transferable and does not extend to any subsequent owners. Expendable parts are not covered under this warranty.
During the warranty period, a Madimack-authorized reseller will repair or replace defective parts with new or, at Madimack’s discretion, serviceable used parts that meet or exceed the performance of new components
This Limited Warranty extends only to products purchased from a Madimack authorised dealer. Does not extend to any product that has been damaged or rendered defective. (a) as a result of accident, misuse or abuse; (b) as a result of natural disaster; (c) by operation outside the usage parameters stated herein; (d) by the use of parts not manufactured or sold by Madimack; (e) by modification of the product; (f) as a result of war or terrorist attack; or (g) as a result of service by anyone other than Madimack authorised dealer or authorized agent.
EXCEPT AS EXPRESSLY NO OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. MADIMACK EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS EXPRESS LIMITED WARRANTY.
CARTRIDGE FILTERS
17
Documents / Resources
![]() |
madimack eliteCLEAR Series Cartridge Filter [pdf] Instruction Manual EliteCLEAR 150, EliteCLEAR 200, eliteCLEAR Series Cartridge Filter, eliteCLEAR Series, Cartridge Filter, Filter |