User Guide for MEAN WELL models including: HRP-200-3.3, HRP-200-5, HRP-200-7.5, HRP-200-12, HRP-200-15, HRP-200-24, HRP-200-36, HRP-200-48, HRP-200 Series 200W Single Output with PFC Function, HRP-200 Series, HRP-200 Series 200W PFC Function, 200W Single Output with PFC Function, 200W Single Output with PFC, Single Output with PFC, Output, PFC, PFC Function

HRP-200-20240126

wangj

HRP-200 series

Datasheet - HRP-200-12

MEAN WELL Switching Power Supply, HRP-200-12, 12V dc, 16.7A, 200W, 1 Output, 110/230V Input Voltage | RS

Datasheet - HRP-200-36

MEAN WELL Switching Power Supply, HRP-200-36, 36V dc, 5.7A, 200W, 1 Output, 110/230V Input Voltage | RS


File Info : application/pdf, 2 Pages, 143.71KB

PDF preview unavailable. Download the PDF instead.

A700000011943088
200W Single Output with PFC Function

HRP-200 series

 GTIN CODE

 Features :

User's Manual

Universal AC input / Full range

Built-in active PFC function, PF>0.95

High efficiency up to 89%

Withstand 300VAC surge input for 5 seconds

Protections: Short circuit / Overload / Over voltage / Over temperature

Cooling by free air convection

Built-in constant current limiting circuit

1U low profile 38mm

Built-in remote sense function

5 years warranty

MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION

AS/NZS 62368.1

Bauart gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1 TPTC004

IEC62368-1

MODEL

HRP-200-3.3 HRP-200-5 HRP-200-7.5 HRP-200-12 HRP-200-15 HRP-200-24 HRP-200-36 HRP-200-48

DC VOLTAGE RATED CURRENT CURRENT RANGE

3.3V 40A 0 ~ 40A

5V 35A 0 ~ 35A

7.5V 26.7A 0 ~ 26.7A

12V 16.7A 0 ~ 16.7A

15V 13.4A 0 ~ 13.4A

24V 8.4A 0 ~ 8.4A

36V 5.7A 0 ~ 5.7A

48V 4.3A 0 ~ 4.3A

OUTPUT

RATED POWER

132W

175W

200.3W

200.4W

201W

RIPPLE & NOISE (max.) Note.2 80mVp-p

90mVp-p

100mVp-p 120mVp-p 150mVp-p

VOLTAGE ADJ. RANGE

2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V

10.2 ~ 13.8V 13.5 ~ 18V

VOLTAGE TOLERANCE Note.3 ±2.0%

±2.0%

±2.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.3%

±0.3%

LOAD REGULATION

±1.5%

±1.0%

±1.0%

±0.5%

±0.5%

SETUP, RISE TIME

1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC 16ms/115VAC at full load

201.6W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5%

205.2W 250mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5%

206.4W 250mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5%

VOLTAGE RANGE Note.5 85 ~ 264VAC

FREQUENCY RANGE

47 ~ 63Hz

120 ~ 370VDC

POWER FACTOR (Typ.)

PF>0.95/230VAC PF>0.99/115VAC at full load

INPUT EFFICIENCY (Typ.)

80%

84%

86%

88%

88%

88%

89%

89%

AC CURRENT (Typ.) INRUSH CURRENT (Typ.)

2.1A/115VAC 1.1A/230VAC 35A/115VAC 70A/230VAC

LEAKAGE CURRENT

<1.2mA / 240VAC

OVERLOAD PROTECTION
OVER VOLTAGE

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

3.96 ~ 4.62V 6 ~ 7V

9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V

Protection type : Shut down o/p voltage, re-power on to recover

57.6 ~ 67.2V

OVER TEMPERATURE WORKING TEMP.

Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +70 (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved

SAFETY & WITHSTAND VOLTAGE

EMC (Note 4)

ISOLATION RESISTANCE EMC EMISSION

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY MTBF

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,heavy industry level, EAC TP TC 020 1830.6K hrs min. Telcordia SR-332 (Bellcore) ; 209.5K hrs min. MIL-HDBK-217F (25)

OTHERS NOTE

DIMENSION

199*98*38mm (L*W*H)

PACKING

0.77Kg; 18pcs/14.9Kg/0.87CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).
 Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:HRP-200-SPEC 2024-01-26

200W Single Output with PFC Function

HRP-200 series

Mechanical Specification

Case No.902E Unit:mm
197

7

9

3.5

3-M3 L=5
3.5  15 26

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment

1

AC/L

4,5 DC OUTPUT -V

2

AC/N

6,7 DC OUTPUT +V

3

FG

Connector Pin No. Assignment (CN100) :

HRS DF11-6DP-2DS or equivalent

Pin No. Assignment Mating Housing Terminal

1

NC

2

NC

3

NC

HRS DF11-6DS HRS DF11-**SC

4

NC

or equivalent or equivalent

5

+S

6

-S

8.2

9.5

9 18.5

1

2

3

4

5

6

7



LED

3.5

CN100

SVR1

4.5

57.5

6.5

13max. 28

80

4-M3 L=5 120
199 190
151

Block Diagram

EMI

I/P

FILTER

FG

ACTIVE INRUSH CURRENT LIMITING

RECTIFIERS &
PFC
O.T.P.
PFC CONTROL

POWER SWITCHING
O.L.P.
PWM CONTROL

RECTIFIERS &
FILTER
DETECTION CIRCUIT
O.V.P.

Derating Curve

Output Derating VS Input Voltage

18 9.5 3.5 28.5 38

PWM fosc :70KHz
+S +V -V -S

85.5

98

LOAD (%) LOAD(%)

112050

100

90

80 80

60

70

60 40
50 20
40

-40

0

10

20

30

40

50

60

70 (HORIZONTAL)

85

100

125

135

155

264

AMBIENT TEMPERATURE ()

INPUT VOLTAGE (V) 60Hz

File Name:HRP-200-SPEC 2024-01-26



References