User Guide for MEAN WELL models including: HRP-200-3.3, HRP-200-5, HRP-200-7.5, HRP-200-12, HRP-200-15, HRP-200-24, HRP-200-36, HRP-200-48, HRP-200 Series 200W Single Output with PFC Function, HRP-200 Series, HRP-200 Series 200W PFC Function, 200W Single Output with PFC Function, 200W Single Output with PFC, Single Output with PFC, Output, PFC, PFC Function
MEAN WELL Switching Power Supply, HRP-200-12, 12V dc, 16.7A, 200W, 1 Output, 110/230V Input Voltage | RS
MEAN WELL Switching Power Supply, HRP-200-36, 36V dc, 5.7A, 200W, 1 Output, 110/230V Input Voltage | RS
File Info : application/pdf, 2 Pages, 143.71KB
DocumentDocument200W Single Output with PFC Function HRP-200 series GTIN CODE Features : User's Manual Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit 1U low profile 38mm Built-in remote sense function 5 years warranty MW Search: https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION AS/NZS 62368.1 Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 TPTC004 IEC62368-1 MODEL HRP-200-3.3 HRP-200-5 HRP-200-7.5 HRP-200-12 HRP-200-15 HRP-200-24 HRP-200-36 HRP-200-48 DC VOLTAGE RATED CURRENT CURRENT RANGE 3.3V 40A 0 ~ 40A 5V 35A 0 ~ 35A 7.5V 26.7A 0 ~ 26.7A 12V 16.7A 0 ~ 16.7A 15V 13.4A 0 ~ 13.4A 24V 8.4A 0 ~ 8.4A 36V 5.7A 0 ~ 5.7A 48V 4.3A 0 ~ 4.3A OUTPUT RATED POWER 132W 175W 200.3W 200.4W 201W RIPPLE & NOISE (max.) Note.2 80mVp-p 90mVp-p 100mVp-p 120mVp-p 150mVp-p VOLTAGE ADJ. RANGE 2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% LOAD REGULATION ±1.5% ±1.0% ±1.0% ±0.5% ±0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load 201.6W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5% 205.2W 250mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5% 206.4W 250mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5% VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 120 ~ 370VDC POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.99/115VAC at full load INPUT EFFICIENCY (Typ.) 80% 84% 86% 88% 88% 88% 89% 89% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.1A/115VAC 1.1A/230VAC 35A/115VAC 70A/230VAC LEAKAGE CURRENT <1.2mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover 57.6 ~ 67.2V OVER TEMPERATURE WORKING TEMP. Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved SAFETY & WITHSTAND VOLTAGE EMC (Note 4) ISOLATION RESISTANCE EMC EMISSION I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY MTBF Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,heavy industry level, EAC TP TC 020 1830.6K hrs min. Telcordia SR-332 (Bellcore) ; 209.5K hrs min. MIL-HDBK-217F (25) OTHERS NOTE DIMENSION 199*98*38mm (L*W*H) PACKING 0.77Kg; 18pcs/14.9Kg/0.87CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:HRP-200-SPEC 2024-01-26 200W Single Output with PFC Function HRP-200 series Mechanical Specification Case No.902E Unit:mm 197 7 9 3.5 3-M3 L=5 3.5 15 26 Terminal Pin No. Assignment Pin No. Assignment Pin No. Assignment 1 AC/L 4,5 DC OUTPUT -V 2 AC/N 6,7 DC OUTPUT +V 3 FG Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DS or equivalent Pin No. Assignment Mating Housing Terminal 1 NC 2 NC 3 NC HRS DF11-6DS HRS DF11-**SC 4 NC or equivalent or equivalent 5 +S 6 -S 8.2 9.5 9 18.5 1 2 3 4 5 6 7 LED 3.5 CN100 SVR1 4.5 57.5 6.5 13max. 28 80 4-M3 L=5 120 199 190 151 Block Diagram EMI I/P FILTER FG ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC O.T.P. PFC CONTROL POWER SWITCHING O.L.P. PWM CONTROL RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. Derating Curve Output Derating VS Input Voltage 18 9.5 3.5 28.5 38 PWM fosc :70KHz +S +V -V -S 85.5 98 LOAD (%) LOAD(%) 112050 100 90 80 80 60 70 60 40 50 20 40 -40 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:HRP-200-SPEC 2024-01-26