User Manual for Sunco models including: WR_PR7_DU-WH-4060K 7 Inch LED Prismatic Lens Wraparound Selectable Light, WR_PR7_DU-WH-4060K, 7 Inch LED Prismatic Lens Wraparound Selectable Light, Prismatic Lens Wraparound Selectable Light, Lens Wraparound Selectable Light, Wraparound Selectable Light, Selectable Light
Installation Guides, Manuals, and Specs | Sunco – Sunco Lighting
Sunco LED 7 Inch Linkable Utility Industrial Commercial Warehouse Garage Ceiling Prisma Wraparound Light, 12.5W/25W/50W 6500 Lumens, Selectable CCT 4000K/5000K/6000K, Non-Dimmable, AC120-277V 4 Pack
LED Prisma Wraparound, 50W/25W/12.5W, 4ft x 7in, Selectable Wattage & – Sunco Lighting
Lighting made better. User Manual 7" LED Prismatic Lens Wraparound Selectable Light SKU: WR_PR7_DU-WH-4060K support@sunco.com (844) 334-9938 AMERICAN COMPANY Whats in the Box? Wraparound Le(tlittheerraellbye) light! Components x1 Light Fixture x2 Screws(15mm) #8 - 32 x4 Wood Screws ST4 x3 Heat-shrink Tube12 x3 Wire Nuts (P3) x4 Wall Anchors x3 Wire Connectors (CE5) 1 x4 Inner Toothed Washer Before You Start Safety Information To reduce the risk of fire, electric shock, or physical injury: · Turn off power before changing fixture. · Suitable for use in damp environments at temperatures ranging from -4°F to 104°F. Not for use where directly exposed to water. · Not intended for use with emergency fixtures. · Not compatible with photo-electric sensors. · Not compatible with motion sensors. · Not compatible with third party sensors. · Not compatible with dimmers. For more dimming information, please visit www.sunco.com. · Not compatible with timing devices. · All electrical connections must be in accordance with local and National Electric Code (N.E.C.) standards. · Please review installation manual carefully before proceeding. Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections. WARNING: Cancer & Reproductive Harm- www.P65Warnings.ca.gov This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.) This device may not cause harmful interference. 2.) This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation. Quickstart Guide Step 1 Label wires when replacing fixtures. A A Conduit LINKING a bc Step 2 Screw (AA) into junction box, leaving 1/4" exposed. 22 Step 3 Press for secure, audible "click." Step 4 Reattach diffuser & secure with aluminum base. Installation Guide (Junction Box Installation) ON OFF STEP 1 a. Turn off circuit breaker before installation. b. For fixture replacement, sketch or label wires for reference. 4000K 5000K 6000K 6500LM 2600LM 1625LM STEP 2 a. Remove the diffuser from the lamp base. b. Select desired color temperature and brightness. STEP 3 a. Screw (AA) into junction box, leaving 1/4" exposed for lamp. A b. In the junction box, connect wires: A Live (black) to Live ; Neutral (white) to Neutral ; Ground (yellow/ green) to Ground. Secure with wire nuts and tuck into the box. 3 Installation Guide (Cont.) STEP 4 a. Align Lamp Base holes with junction box screws. b. Rotate Lamp Base clockwise to secure it, and tighten screws for fixture stability. Conduit LINKING a bc STEP 5 a. Punch an end cap hole, remove cables from the lamp base, and connect wires: Live (black) to Live, Neutral (white) to Neutral, Ground (yellow/green) to Ground. b.The wiring between the fixtures is clamped with a wire connectors to ensure that the clamping is not loose, and then put on the heat shrink tube to tighten. c. Size of conduit 1 inch ( 1/2" 3/4" 1" ) STEP 6 a. Reattach the diffuser (cover): Align one end and gently press down. Push the diffuser to the corner of the lamp base. Secure the diffuser with the aluminum base. b. Restore power by turning on the circuit breaker and test the light. 4 Installation Guide (Keyhole Installation) A B STEP 1 a. Turn off circuit breaker before installation. b. For fixture replacement, sketch or label wires for reference. c. The mounting surface must support the fixture's weight. Detach the diffuser from the lamp base. Mark these locations (mounting surface) STEP 2 a. Choose your preferred color temperature and brightness. b. Align the Lamp Base with the mounting location using the knockout holes. Mark the 4 keyhole slots at each end of the housing. Drywall Drywall mounting STEP 3 DRYWALL MOUNTING (No Stud): Drill 4 small pilot holes with a 7/32" bit (not included). Insert wall anchors with a hammer. Partially tighten 4 wood screws, leaving a 3/8" gap between the screw head and the mounting surface. 5 Installation Guide (Cont.) Wall stud Pilot hole Wall stud mounting STEP 4 a. WALL STUP MOUNTING OPTION Drill 4x small pilot holes with a 9/64" drill bit (not included). Install 4x wood screws into the mounting surface, but not fully. Leave about a 3/8" gap between the screw head and mount surface. B A a bc STEP 5 a. Take out the cables from the lamp base. Remove shrink wrap, connect wires: Live (black) to Live, Neutral (white) to Neutral, Ground (yellow/green). b. Insert screws into keyhole slots, slide lamp base (a) to align screw heads, and secure fixture to mounting surface. Use provided washer for added vibration protection. STEP 6 a. Reattach the diffuser, align and secure with metal base. Restore power and test the light. b. Turn on circuit breaker and the test light. 6 Product Details Recommended Dimmers 2.5" 7" 48" Specifications Voltage Wattage Power Factor Amps CCT Housing Material Dimmable 120V-277V 12.5W/25W/50W 0.7 0.495Am 4000K/5000K/6000K PC+Steel Non-dimmable 7 Average Lifetime Lumens Temperature CRI Efficacy Usage Warranty 50000 hrs 1625/2600/6500LM -4°F to 104°F 80+ 130lm/w Indoor 7 Years Common Troubleshooting Feeling in the dark about an issue with your product? No If you still need some assistance, please feel free to worries! Our troubleshooting section is here to shed some light contact us with any questions. Our team of lighting experts and provide you with easy-to-follow solutions for any problem. are happy to help brighten your day. Installation Light isn't turning on. Double check if fixture is properly connected and circuit breaker hasn't been tripped. Light unexpectedly fails. Dimming Light not dimming to lowest setting. Light not dimming smoothly. Light not compatible with dimmer switch. Flickering Light is flickering when turning on. Light flickering with other lights on the same circuit. Light flickering when turned on. Light flickering when dimmed. Buzzing Fixture buzzing with power outages. Fixture buzzing with appliances or electronic devices. Fixture buzzing when dimmed. For further assistance, reach out to customer support. Light not dimmer compatible. Light not dimmer compatible. Light not dimmer compatible. Check that fixture wiring connections are secure. Check that the lights on the same circuit are not overloading the circuit. Verify fixture compatibility and that it is grounded. Light not dimmer compatible. Verify light is connected to surge protector securely. Look for nearby interferences that can cause buzzing. Such as televisions, radios, computers, etc. Light not dimmer compatible. 8 Light Distribution Angle Not No awloirgrhietisn, ygonuercda?n skip this page AVERAGE BEAM ANGLE (50%): 94.4 DEG C0/180 89.1° C90/270 99.7° Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles: A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting. UNIT:cd Luminous Intensity Distribution 1 An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more. It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated. 9 Customer Support Warranty Policy This product is covered by our industry leading 7 year warranty. It gets even better - scan the QR code for 2 extra years of protection! Secxatnramyeeafrosr! two 30 Day Return Policy At Sunco, we value our customers and stand by the quality and performance of our products. If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date. Customer Service Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at: Email: support@sunco.com Call or Text: (844) 334-9938 10 Lighting made better. support@sunco.com (844) 334-9938 REV1.0 AMERICAN COMPANYAdobe PDF Library 17.0 Adobe InDesign 19.1 (Windows)