User Manual for MINIWARE models including: MDP-P905, Digital Power Module, MDP-P905 Digital Power Module, Power Module
Купить программируемый источник питания Miniware MDP-P905 в Суперайс
MDP-P905 User Manul Of Digital Power Module Before using this product, please read this manual (This user's manual written based on firmware version V1.20) table of Contents Describes the functional 2 Operation panel interface 3 2.1 groundwork interface 3 2.2 the voltage-current adjustment setting screen (when toggle wheel) 4 2.3 browse display mode 5 2.4 Settings menu 6 2.5 Rapid setting voltage and current menu 6 2.6 Wireless address modification method 7 The method 8 Described in 9 Appendix indicator definitions updates 1 9 1 Operation Panel Explains Light output terminal CC / CV RUN SET MENU LOCK <- +> 1) SET Set Panel Lights LOCK / CONNECT Figure 1.0 The main function switching voltage and current adjustment item; Press to select sub-functions; coarse enable parameter is set. Dial 2) MENU menu Switch the display contents of the main function to check the current settings. Press sub function menu setting change parameter values. 3) RUN / LOCK output / Lock The main function output enable. Deputy Press locking function parameters. 4) Dial The main function to change the value. Vice feature to jump to change the menu setting parameter values. 5) Priority key Key RUN / LOCK high priority. Keys MENU, and SET low priority roller. 6) Shortcuts: Press SET button and simultaneously press the MENU key is provided into the rapid voltage and current selection menu,ENCODER using preset switching cycle, the SET select a preset output interface and switching to the operating state, a timeout without selection or click Exit Exit MENU, press MENU no operation. 2 Each function interface 2.1 Foundation work Interface RUN / LOCK: 1) output on or off operation: Press (less than 2 seconds), the output on or off, the highest priority. Immediately determined difference between the current real-time voltage and current provided to the open current voltage if the output is turned on (refer to the Appendix 1) 2) Parameter lock and unlock methods: Press more than 2 seconds to lock the trigger parameters, first press flipping only once. SET key lock function can not operate, voltage and current can not be provided, there is no way to display and control the remote control of the present power supply. Note: Each output is not turned on by default, you need to press once before opening. 2.1.1 Open output interface This roller adjustment term I / U. A lock display pattern of the locking Status areaON / CC / CV / OFF Real-time voltage Real-time current Channel number displayed after the connection is displayed Real-time power 2.1.2 off the output interface This roller adjustment term I / U. Display a lock pattern lock Setting voltage Setting current Status areaON / CC / CV / OFF Channel number displayed after the connection is displayed Real-time power 3 2.2 the voltage-current adjustment setting screen (when toggle wheel) 2.2.1 Select Set voltage or current Method: In the non-LOCK state, the main interface SET key press, to modify the "current wheel adjustment item" ( I or U ) . select U Modify setting voltage value represents; choose I It represents the set current value to modify. 2.2.2 change the settings worth method: In the non-LOCK state, normal operation when toggle wheel interface, the original display region of the power set value becomes the display region does not change the real-time voltage and current; LOCK mode change state can not enter the setting value. No operation 1 second after the wheel, the power set value back to the display. When the setting item to the roller I Time , Toggle wheel operating current setpoint, 0.005A ~ 5.000A; wheel is U When toggle wheel operating voltage set value, 0.01. ~ 30.000V. This roller adjustment term I / U. A lock region display pattern of the locking Status areaON / CC / CV / OFF Real-time voltage Channel number displayed after the connection is displayed Real-time current Real-time power This roller adjustment term I / U. A lock region display pattern of the locking real-time voltage Real-time current After the toggle wheel Status areaON / CC / CV / OFF Voltage and current settings Numerical Channel number displayed after the connection is displayed Voltage and current settings title 4 2.2.3 How coarse or fine change the values: Coarse: Long press the SET key, while the toggle trackwheel, a coarse adjustment voltage 0.3V per step, stepping current 30mA. Fine: when SET key is not pressed, a jog dial, when the voltage step 0.01V, current stepping 1mA. 2.2.4 The factory default setting voltage 3.000V, the default setting current 1.000A. 2.3 Browse menu display 2.3.1 Press the button DISP / MENU Enter browsing mode (Figure1.1), Press again to immediately return to the main interface; 2.3.2 Corresponds to the scroll wheel turning (without circulation), view the current status and power settings in the browser mode 5 seconds-free operation automatically returned to the main interface; 2.3.3 RUN / LOCK key operation does not affect the current display content type and category. Page Display menu Real-time voltage Real-time current Status areaON / CC / CV / OFF display and control channel number display is connected to the after Display menu title Display menu information Figure 1.1 In the main interface short press DISP / MENU displays basic setting parameters: 1 ) Input voltage Inp Vol 2 ) Input current Inp Cur 3 ) Input current limit Inp Cur 4 ) Machine temperature Temp; 5) version information. as follows: 5 Displaying a menu page Real-time voltage Real-time current status area: ON / CC / CV / OFF Channel number displayed after the connection is displayed Device ID number Software version number Hardware version number 2.4 Setting menu Press button DISP / MENU enter the setup menu by the SET key, to cycle solid angular position, ENCODER scrolling menu item pointing triangle "Menuitem"; ENCODER to adjust the setting value triangle pointing to "Value"; Indicates to the title item, indicating title that the menu item is scrolled Solid triangles Numerical adjustment item page number 1) Set Menu 1: Input current limit; 2) Set Menu 2: Automatically match the radio address and TX RX Addr, when the wireless address match, if the power output on the basis of safety, will be forced to shut down the power supply output; 3) Set Menu 3: sound volume adjustment Sound Adjuset. 2.5 Rapid setting voltage and current menu Press SET button and MENU button to enter the fast selection screen, as shown below; ENCODER preset value using Cycle SET button to select a corresponding preset values and switches the output interface to the operating state without selection or click MENU Exit Exit timeout, no operation press MENU 6 serial number Set voltage Set Current The default value can be modified by Q_SET.TXT documents, the contents of the file as shown below, changes take effect after the restart. Serial number (up to 10) Set voltage (0.01V ~ 30. 000V) Set current (0.005A ~ 5. 000A) File name 2.6 Wireless address modification method Power can enter the U disk to modify wireless radio frequency with the address of the file to match the display and control, the document called RX_ADDR.TXT, the contents of the file as shown below, changes will take effect after reboot. Wireless Address Radio frequency file name 7 Indicator Definition A: lamp output terminal (for details see FIG. 1): Normal full light output, it turns off when the output is off, the output off after 1 minute, go to sleep output off after six minutes, Quanmie off. B: panel lights (for details see FIG. 1): 1) When the output is off, the blue light in the upper respiratory state; 2) an output, the constant-voltage-red light when in the state, when a constant current upper full bright light blue; 3) when the locking force, the lower side of the red light; 4) when the alarm (including input overvoltage, overheating, power supply fails, the output to reach its own alarm condition)Red light flashes up and down at the same time. Light-bit Light output terminal State Bright flame Often off Red light 1 Blue lights 2 Always put out Bright flame Always off Bright flame Always put out Red light 2 Green light 1 Bright flame Always put out Bright flame sparkle Turn off the flash Up and down the red sparkle Meaning Turn on the output Turn off the output Standby, screen off Turn on the output,state of the constant voltage CC Turn off the output Turn on the output, constant current CV state Turn off the output Parameter lock Parameter not locked not disconnected Select the extension has been disconnected has been disconnected alarm 8 Upgrade Press the power button of the SET, while usb connected to the computer with the USB cable, the computer name will appear: DFU Vx_xx_x removable hard disk, the Prepared .hex firmware copied to the root directory of the mobile disk, the firmware when the extension becomes .rdy .hex, power restart, the firmware is completed upgrade. Appendix 1 Description Note that (abnormalities alarm description): 1. If the interface displays "Factory Fail", the default parameter file read exception. 2. If the interface displays "Param Error", the power anomaly reads the parameter file. 3. If the interface displays "Quick Setting Error", the rapid voltage and current provided abnormal parameter files. 4. The input current exceeds the set current value of + 20% of the alarm, the interface displays "INPUT ELEC ERROR", buzzer, double red flash. 5. The input voltage is lower than 3V alarm, display interface "INPUT VOLT ERROR", buzzer, double flash red. 6. When the device temperature is less than 0 degrees, greater than 70 degrees, it will shut down. 7. When the screen displays "Flash Error", flash chips exception. 8. When the screen displays "Wireless Error", the wireless chip exception. 9CorelDRAW(Foxit Advanced PDF Editor) iLovePDF