Instruction Manual for TEMPO COMMUNICATIONS models including: PA1574 Network Tester, PA1574, Network Tester, Tester

Description Important Safety ...

Description Important Safety Information Specifications Operation Descripción Importante In sobre Seguri Especificacio Funcion


File Info : application/pdf, 2 Pages, 354.25KB

PDF preview unavailable. Download the PDF instead.

850217
INSTRUCTION MANUAL
PA1574 RJ45 Network Tester
52082081 REV 02 © 2019 Tempo Communications Inc. 11/19
Description
The PA1574 RJ45 Network Tester is a continuity tester for UTP and flat satin cables with RJ45 terminations. This tool tests both data and telephone connection schemes including patch cords and installed cables to identify good connections, opens, shorts, and cross-connections. Note: Will also test RJ11 and RJ12 connections. Keep this manual available to all personnel. Replacement manuals are available upon request at no charge at www.TempoCom.com.
Do not discard this product or throw away! For recycling information, go to www.TempoCom.com.
All specifications are nominal and may change as design improvements occur. Tempo Communications Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
Important Safety Information
Electric shock hazard: Contact with live circuits could result in severe injury or death.
Specifications
Weight: 5.15 oz (146 g) Dimensions:
Main Unit: 4.25" L x 2.48" W x 1.10" D (108 mm x 63 mm x 28 mm)
Remote Unit: 4.25" L x 1.38" W x 1.10" D (108 mm x 35 mm x 28 mm)
Output (main unit): 9 VDC nominal at 3 mA max. Connection Type: RJ11, RJ12, and RJ45 UTP modular plug Battery: 9 VDC Battery Life: 50 hours continuous use Max. Cable Length: 1000 ft (300 m)
Operation
Testing Cables for Pin-out Wiring Configuration (Cable Mapping)
1. To test local patch cables, connect the cable between the RJ45 sockets on the top side of the main test unit.
2. To test installed cables, use a patch cable to connect the main test unit RJ45 socket to the wall jack. Use a patch cable to connect the remote unit to the wall jack or hub at the opposite end of the cable.
3. Turn the main unit "on/off" switch to the "on" position. The "on" position will provide a fast test. Move the switch to the "slow" position for a slow test.
4. Read the lights for pins 1 through 8 on the main unit for patch cables, or for installed cables use the LEDs on the main unit and remote, to determine connections through the cable.
5. Refer to test examples on reverse for determining cable faults.
6. If the cable being tested does not have a shield, the G LEDs will not illuminate.

Patch Cable Testing / Installed Cable Testing Pruebas de cables de conexión / Pruebas en cables instalados Contrôle de câble de raccordement / Contrôle de câble installé

Good Connection ­ Pin 4-to-Pin 4 Buena conexión ­ Clavija 4-a-clavija 4 Bonne connexion ­ Broche 4 à broche 4

A

B

Cross Connection ­ Pin 4-to-Pin 6 Conexión cruzada ­ Clavija 4-a-clavija 6
Inversion ­ Broche 4 à broche 6

A

B

1

1

1

1

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

7

8

8

8

8

G

G

G

G

Open Connection ­ Pin 4 Conexión abierta ­ Clavija 4 Connexion ouverte ­ Broche 4

A

B

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

G

G

A = Main Unit Out B = Remote
A = Salida de unidad principal
B = Unidad remota
A = Appareil principal Out B = Appareil secondaire

Sample Test Results / Ejemplo de resultados de prueba / Exemple de résultats de mesure

Remote Lights Luces remotas Voyants d'appareil secondaire 1 2 3 4 5 6 7 8 G 2 1 3 4 5 6 7 8 G 1 2 & 3 2 & 3 4 5 6 7 8 G 1 2 3 ­ 5 6 7 8 G 1 2 4 3 6 5 7 8 G 1 2 3 7 5 6 4 8 G 1 2 3 4 5 6 7 ­ G 1 2 3 7 5 6 4 8

Cable Fault None, cable wired correctly Conductors 1 & 2 reversed Conductors 2 & 3 are shorted Conductor 4 is open Pair 3/6 is transposed with pair 4/5 Conductors 4 & 7 are switched Conductor 8 is open No shield or bad shield

Fallo de cable Ninguno, cable alambrado correctamente Conductores 1 y 2 invertidos Conductores 2 y 3 están en cortocircuito Conductor 4 está abierto Par 3/6 está traspuesto con el par 4/5 Conductores 4 y 7 están conmutados Conductor 8 está abierto Sin protección o con protección deficiente

Défaut de câble Néant, câble correctement broché Conducteurs 1 et 2 inversés Conducteurs 2 et 3 en court-circuit Conducteur 4 ouvert Paire 3/6 transposée avec la paire 4/5 Conducteurs 4 et 7 commutés Conducteur 8 ouvert Pas de blindage ou mauvais blindage

Tempo Communications 1390 Aspen Way · Vista, Ca 92081 · USA 800-642-2155 · Latin America: 760-510-0558

EMEA Tempo Europe Ltd.· Brecon House, William Brown Close Cwmbran, NP44 3AB, UK Tel: +44 1633 927 050



References

Adobe PDF Library 15.0 Adobe InDesign 15.0 (Windows)