GE Fit Plus LN Smart Body Fat Scale
User Manual
Precautions
Read carefully before use:
- Do not use the body fat scale if you have a pacemaker or any other internal medical device in your body. The scale passes a low, harmless electrical current through your body, which may cause internal medical devices to malfunction.
- Do not use the scale on a wet surface, as this could lead to slipping.
- Dispose of the scale properly following your local regulations.
- Do not jump on the scale. This scale has a weight limit of 500 lbs.
Scale Overview
The GE Fit Plus LN Smart Body Fat Scale measures weight, BMI, body fat %, and other body compositions using bioelectrical impedance analysis (BIA) technology. This smart scale is intended for home use only.
① LED Display, ② Electrodes, ③ Tempered Glass Surface, ④ Scale Feet, ⑤ Battery Box
Unit: * st lb kg
Bluetooth Connection
Weight Decrease- / Weight Increase+
Body Composition Metrics: Underweight, Normal, Overweight, Obesity, BMI, Body Fat %, Muscle Mass %, Bone Mass %, Body Water %, Visceral Fat %
Scale Specifications
- Model: Fit Plus LN
- Dimensions: 11.81x11.81x0.94 inches / 300x300x24mm
- Weight: 3.7lb / 1.7kg
- Weighing Range: 0.4-500 lb / 0.2 - 226.8 kg
- Power: 3*1.5V AAA batteries
Get Started
Initial setup requires one-time device pairing and profile creation in the app. All data is viewable on your scale afterward without needing your phone.
-
Download the app and create an account
Download the "Fit Profile" app from the App Store (iOS) or Google Play Store (Android). Search for "Fit Profile" or scan the QR code provided.
Note: Do not mix new and old batteries. Remove batteries if the scale will not be used for a long period.
Sign up and complete your profile.
-
Pair scale with smartphone
Ensure Bluetooth is enabled on your phone. For Android 6.0 and above, Location must also be enabled.
Pairing is automatic, and the Bluetooth icon will display on the scale screen.
- Place the scale on a hard, flat floor surface.
- Open the "Fit Profile" app and turn on your smartphone's Bluetooth.
- In the app's home page, click "Pair the Device" or the icon in the top-right corner, tap "My Device", then tap "Smart Bathroom Scale".
- Turn on the scale by briefly stepping on and off it.
- Select "Fit Plus LN" and tap "Connect".
Your scale is now paired and ready for measurements.
Note: Ensure your height and other profile data are filled in for accurate measurements.
Pairing Steps: 1. Download Fit Profile app and register. 2. Select Unit. 3. "Pair the device" in app home page and tap your scale to connect. 4. Add height and more data, then step on the scale to measure.
-
Take measurements
- Open the "Fit Profile" app and keep it on the "Home" screen.
- Place the scale on a hard, flat floor surface. Do not place it on carpet or other soft surfaces.
- Turn the scale on by stepping on and off, waiting for "0.0" to display.
- Step on the scale barefoot until the buzzer beeps twice or all numbers display. Your measurement is complete, and results will appear in the app.
Multiple User Profiles
Separate Fit Profile Accounts
Users can create or log in to individual Fit Profile accounts and pair the smart scale with their personal accounts. Weight data is private and can be synced with third-party apps.
Shared Fit Profile Account
Users with a Fit Profile account can create multiple user profiles within the same account. All users can log in to the shared account on their smartphones without needing others to log out.
To add users and share your account, click the icon in the top-left corner of the app's home screen.
Note: Users sharing an account can access each other's recorded data. Only the main user's data can be synced with third-party apps.
Athlete Mode
If you have an athletic build, you can turn on Athlete Mode. Open the Fit Profile app, go to the "Me" page, tap your profile name, and select "Athlete Mode".
Switching Units
By default, the scale uses pounds (lb). It also supports kilograms (kg).
To switch units, connect the scale to the Fit Profile app, go to the "Me" page, select "Settings", then "Unit".
Measurement Tips
DO's
- Ensure personal information in your profile is correct. Choose "Athlete Mode" if you work out intensively or are muscular.
- Place the scale on a hard, flat floor surface.
- Calibrate the scale each time by waiting for "CAL" to return to "0.0" before stepping on.
- Use the scale under the same conditions and at the same time each day.
- Empty your bladder before weighing.
DON'Ts
- Do not place the scale on a carpet or soft surface.
- Do not measure with socks or shoes on.
- Do not measure when your body is wet (e.g., after a shower, bath, sauna, or strenuous exercise).
- Do not measure after drinking a lot of water or alcohol.
- Do not measure if you have a cold or fever.
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Lo | Low power | Use new 1.5V AAA batteries. |
EEr | Overload | Use the scale within 500 lbs. |
EErI | Unstable measurement | Place the scale on a flat, hard surface and measure again. |
--- (Unable to calibrate) | Unable to calibrate | Place the scale on a flat, hard surface and let it calibrate. |
No Display | Auto-off, or no power | Auto-off: Step on then off to turn on the scale. No power: replace batteries. |
Display Weight Only | Incomplete profile data in the app | No User Profile: Create an app profile and weigh once with Bluetooth connected. No Electrical Current: Stand on the scale barefoot. Users: Not suitable for children under 10. Other Issues: Contact Customer Support. |
Unable to Sync with App | Lost connection, or scale turns off | Reconnect the scale: For iPhones, authorize Bluetooth; for Android, enable location. In the app, click the icon at the top-right corner, tap "My Device", then "+ Add device". |
Warranty
This product is warranted by the manufacturer against defects in materials and workmanship for one (1) year from the original date of purchase. Proof of purchase is required.
This warranty does not cover accidental damage, mistreatment, or unauthorized repair. For the detailed warranty policy, visit: www.fit-profile.com/warranty
For any issues or questions, please contact Global eFit Inc.
Contact: Global eFit Inc.
Email: cs@fit-profile.com
Phone: (866) 786-5988 (Mon – Fri. 9:00 am – 5:00 pm, US Central Time)
FCC Compliance Statements
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
ISED Compliance Statements
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions:
- (1) This device may not cause interference.
- (2) This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment.
Company Information
Global eFit Inc.
17304 Preston Road, Suite 800, Dallas, TX 75252, USA
Email: cs@fit-profile.com
Phone: 1-866-786-5988 (toll-free US & Canada; Mon-Fri 9:00am - 5:00pm Central Time)
Model of Independent Module Used in This Product: C21007C10
FCC ID: 2BAI6-GEX00
IC: 30163-GEX00