Instruction Manual for BendPak models including: DT-50, DT-50A, DB-70, MB-240X, DST30P, DT-50 Dannmar and Ranger Wheel Service Equipment, DT-50Dannmar and Ranger Wheel Service Equipment, Ranger Wheel Service Equipment, Wheel Service Equipment, Service Equipment, Equipment
TSB 113-032023 1 of 2 Released March 2023 BendPak Technical Service Bulletin Voltage Selection and Grounding BendPak TSB 113–032023 STOP! – Read these electrical voltage selection and grounding instructions before connecting any of the
File Info : application/pdf, 2 Pages, 315.48KB
DocumentDocumentBendPak Technical Service Bulletin Voltage Selection and Grounding BendPak TSB 113032023 STOP! Read these electrical voltage selection and grounding instructions before connecting any of the Dannmar or Ranger equipment listed here into your facilities' electrical service. The purpose of this Technical Service Bulletin is to describe the input voltage selection and electrical grounding requirements on the Dannmar and Ranger Wheel Service equipment models DT-50, DT-50A, DB-70, MB-240X and DST30P. The Wheel Service equipment models described above will operate on either 110VAC or 220VAC. The Dannmar units are shipped from the factory configured for 110VAC. DANGER All electrical work (including changing a Plug from 110 VAC to 220 VAC) must be accomplished by a licensed Electrician in accordance with national and local electrical codes. If you do not use a licensed Electrician, you void your warranty and put everyone who uses the equipment in danger of injury or, in rare cases, death. To use Dannmar equipment at 110 VAC: 1. Verify the switch on the cabinet of the equipment is set to 110V. Incorrect setting will result in serious damage to the motor and/or electronics, and void your warranty. DANGER Establish and maintain proper earth ground. Voltage or ground hazard sufficient to cause shock, burn or death. 2. Plug the Power Cord into a grounded 110VAC outlet. 3. The unit is ready to operate at 110 VAC. To use the Ranger DST30P equipment at 110VAC: 1. Verify the switch at the back of the equipment is set to 110V. Incorrect setting will result in serious damage to the motor and or electronics, and void your warranty. DANGER Establish and maintain proper earth ground. Voltage or ground hazard sufficient to cause shock, burn or death. 2. Have a licensed Electrician connect a 110VAC NEMA 20 amp plug to the power cord or wire directly into the facility electrical service. 3. Plug the power cord into a grounded 110VAC outlet. If the unit is connected directly into the facility power then no further action is required. The unit is ready to operate. TSB 113-032023 1 of 2 Released March 2023 To use Dannmar equipment at 220 VAC: 1. Verify the switch at the back of the equipment is set to 220V. Incorrect setting will result in serious damage to the motor and/or electronics, and void your warranty. 2. Cut the 110V Plug off the power cord. 3. Have a licensed Electrician connect a 220VAC NEMA 20 amp plug to the power cord or wire directly into the facilities' electrical service. 4. Plug the power cord into a grounded 220VAC outlet. If the unit is connected directly into the facility power, then no further action is required. The unit is ready to operate. DANGER Establish and maintain proper earth ground. Voltage or ground hazard sufficient to cause shock, burn or death. To use the Ranger DST30P equipment at 220VAC: 1. Verify the switch at the back of the equipment is set to 220V. Incorrect setting will result in serious damage to the motor and/or electronics, and void your warranty. 2. Have a licensed Electrician connect a 220VAC NEMA 20 amp plug to the power cord or wire directly into the facilities' electrical service. 3. Plug the power cord into a grounded 220VAC outlet. If the unit is connected directly into the facility power then no further action is required. The unit is ready to operate. DANGER Establish and maintain proper earth ground. Voltage or ground hazard sufficient to cause shock, burn or death. WARNING Do not operate the equipment if there are maintenance issues; instead, take the unit out of service, then contact the dealer, visit bendpak.com/support, email support@bendpak.com, or call (800) 253-2363. © 2023 by BendPak Inc. All rights reserved. 1645 Lemonwood Drive Santa Paula, CA 93060 USA bendpak.com