Hyper S330
Product Specification
This user's manual is made for the YODN illuminator model Hyper S330. To ensure operation safety, maximize device performance, and to familiarize yourself fully with the operation of this illuminator, the manufacture recommends that you study this user's manual thoroughly before operating this device. Please retain this user's manual in an easily accessible place near the work desk for future reference.
Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan
TABLE OF CONTENT
1. Important Notifications 2. Device Introduction 3. Optional Components List 4. Device Specifications 5. Operation Instruction 6. Troubleshooting
Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan
Important Notifications
SAFETY PRECAUTIONS
1. Never power on the device (turn on the lamp) without the liquid light guide and adapter to the microscope attached. UV light is designed to emit from this illuminator during lamp operation; do not directly look into the light without protection, it may damage your eyes. On the other hand, please avoid fix the light output in a fix spot (especially on flammable objects) for a long time as it may cause fire.
2. To replacing the lamp, please make sure the device power is off and unplug the power cord from the outlet, and wait until the lamp and its replacement cover cooled down completely (more than 30 minutes) to avoid accidental electrical shock or burn.
3. Install or place the illuminator unit on a sturdy, level table or bench. 4. Install this device on a flat surface to avoiding blocking the ventilation opening on the sides of
device. Do not place it on a soft surface, i.e. paper or cloth, etc.; this could cause fire. 5. Please ensure leaving sufficient space for ventilation around this device. Never allow metallic
objects to enter from the ventilation opening; this could cause fire or electrical shock. 6. It's recommended to secure sufficient space (larger than 10 cm) around this device to release
the heat generated during operation. 7. To prevent the liquid light guide (optional accessory) from damage, the bend radius of the liquid
light guide must be larger than 60 mm. 8. Always use the power cord provided by the manufacture to ensure the device operated under
its original safety design and performance; fail to do so may void the manufacture product warranty. Keep sufficient distance from the power cord to all possible heat sources and avoid direct contact. 9. Do not power on the device when the lamp replacement cover is open; this could result in electrical shock, burn, illuminator failure, or light guide damages. 10. Please ensure to connect the device power cord to a grounded outlet. Fail to do so may void the intended electrical safety design and device performance. 11. Do not touch the power plug during a thunderstorm to avoid accidental electrical shock.
Getting Ready
1. This user's manual only illustrate to the illuminator. Read also the Instruction Manual of the designated microscope to ensure the microscope and illuminator working together perfectly.
2. This device is a precision optical equipment; please handle it carefully and avoid sudden and severe impact. This device is not waterproof.
Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan
3. Do not operate this device where it is subjected to direct sunlight, dust, steam, or vibration. 4. Highly flammable organic solvent may cause fire. Keep it away from the illuminator when it is in
operation and soon after the illuminator is turned off. 5. Do not twist the liquid light guide (optional accessory) excessively to prevent damaged. 6. Make sure the device is powered off, unplug the power cord from the electrical outlet, and
remove the liquid light guide in the event of transporting the device. 7. Please avoid touch the ventilation opening area during the device operation and immediately
after power off as its temperature might be high and may cause burns. 8. Please avoid turn the device on and off in short period (this device has protective control) as
the lamp is not designed to do so and it will shorten the lamp life.
Maintenance and Storage
1. Clean the device periodically (every 200 hours as a guide). Before cleaning, unplug the power plug from the outlet and wipe it with a fluff-free soft dry cloth.
2. Wipe clean with the soft cloth slightly containing the diluted detergent and use the clean air to blow the dust off if the illuminator and the liquid light guide are very dirty.
3. Never disassemble/remodel anything other than those described in this user's manual. This may cause the optical performance deterioration or incidents; unauthorized disassemble the device will result in product warranty void.
4. When the device is idle, please unplug the power cord from electrical outlet. It is recommend to use the dust prevention cover to cover the device if it's not used on a regular basis or storage; however, please make sure the device is completed cooled off before applying any cover on it.
5. Please replace a new lamp when the lamp energy level drops using the replacement lamp authorized by the manufacture. The mercury lamp design is different from the fluorescence, which contains a high pressure gas within the tube. If the lamp is used beyond its designed lifetime, the glass tube may burst due to the accumulated strain. The used mercury lamp must be disposed of as industrial waste and only to the authorized recycle professionals. Before disposing of this product, be sure to follow your local government regulations and rules.
In the event of lamp burst, please follow the procedures below.  Should the lamp burst, unplug the power cord from the outlet and leave that place while
keeping the place ventilate for at least 30 minutes.  Wait until the lamp and the lamp house have cooled down completely, then use a protective
glove to collect the remaining glass with packing tape and store in a sealable package.  The collected shattered glass and tools used must be sealed completely in a nonmetallic
container, and ask the waste disposer to dispose them as it will contain mercury.
 Should you have inhaled mercury steam, consult the doctor immediately and follow his/her
instructions.
Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan
Device Introduction
Lamp Life Counter Light Output Adjustment

Power Switch

Front
Light Guide Port Lamp & System Cooling Fan

Back

Power Cord Inlet Switch and Fuse

Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan
Optional Components List
Liquid Light Guide (1.5m )
Special Collimator (Adapter to Microscope)
Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan

Device Specifications

Input Voltage

AC 100~240VFull voltage input

Frequency Power Consumption Light Source Drive mode

50 / 60 Hz
Standby: 5W Power On (Lamp Ignition): 165W Power Off(with Cooling): 12.5W YODN AC132W for Hyper S330 Color Temperature (Average): 8000K
AC Type

Light Output Adjustment 9-level Brightness Adjustment- 0% ~ 100%

Protective Function

Lamp Re-ignition Protection Current Overload Protection Lamp Ignition Fail Lock

Lamp Hour Recorder Omron Time Counter

Cooling Function

Forced Electrical Fan to exhaust

Internal Filter

UV / IR Cut Filter

Fuse Type Operating Temp.

Glass Tube Fuse -AC250VM 3A (5.2 x 20mm) 10°C ~ 50°C / 20% ~ 80%RH (No condensation)

Dimensions (H x W x D) 220 x 130 x 365 mm (Except for raised parts)

Weight

5.5 Kgs

Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan

Operation Instruction
A

Mounting the light guide: 1. Insert light guide into the port
(direction of yellow arrow) 2. Screw at part A to fix the light guide
(direction of red arrow)

Mounting the power cord: 1. Insert the power cord inside the switch
socket 2. Turn on the switch to "I" (ON)

Pressing the lamp switch: 1. Under normal operation- green light is
always on 2. When power is off while cooling- red
light is flashing 3. When machine is abnormal- red light
is always on
Light Output Adjustment 1. Turn the knob to adjust the brightness 2. 9-level Brightness Adjustment
(0-100)
Copyright© 2017 YODN Corporation. All rights reserved. www.yodnlighting.com

30077   TEL886-3-563-7218 6F, No. 1, Creation Rd. II, Science-Based Industrial Park, Hsinchu City, 30077 Taiwan

Troubleshooting Guide

Under certain conditions, performance of the unit may be adversely affected by factors other than defects. If the problems occur, please review the list and take remedial action as needed. If you cannot solve the problem after checking the list, please contact your sales representative for assistance.

Trouble

Cause

Remedy

The power of the equipment can not be turned on 

Power cord and plug are not connected properly Connect them correctly





The built-in fuse is blown 

Replace the fuse with a new one 

The lamp cannot be turned onthe cooling fan isn't start The cooling fan or the power supply has failed Contact your sales representative







The lamp has failed or life has expired The lamp cannot be turned onthe cooling fan is operating  the lamp switch flashing red light  The lamp is not mounted properly


Replace with a new lamp 
Mount the lamp properly 

The lamp can be turned on but is unstable 

The lamp has failed or life has expired 

Replace with a new lamp 

The lamp is not mounted properly 

Mount the lamp properly 

The lamp can be turned on but is dark 

The light guide is not mounted properly 

Mount the light guide properly 

Rotate the light volume adjustment dial

The dial value of light volume adjustment is close



toward 100% by each level 100%

The lamp turns off during use 

The lamp has failed or life has expired 
The built-in fuse is blown 

Replace with a new lamp 
Replace the fuse with a new one 