Pioneer Diamante Pro Ductless Wall Mount Split Systems

High Efficiency Heat Pump + DC Inverter in One System

19~23 SEER High Efficiency | Single Zone (9000~36000 BTU/hr) | 110~120V / 208V~230V, 60Hz, 1Ph

Key Features

Standard Features

Technical Specifications

Model WYT009ALS120RL WYT012ALS120RL WYT009GLS120RL WYT012GLS120RL WYT018GLS120RL WYT024GLS120RL WYT030GLS120RL WYT036GLS120RL
System Type DIAMANTE PRO Series High Wall Mount Type Split Heat Pump System (SEER2 20 / Range 19~21)
Modes Cooling, Heating, Dehumidification, Ventilation
Control type Standard set with IR wireless remote (Other optional controllers are available)
Input power supply 110~120V~/60Hz/1P 110~120V~/60Hz/1P 208~230V~/60Hz/1P
Power supply range 99~ 132 VAC 99~ 132 VAC 187~ 253 VAC
Energy Star Rating X X X X
NEEP Rating
Rated cooling capacity (at 95°F) Btu/h 9,000 12,000 9,000 12,000 18,000 24,000 33,000 36,000
Cooling capacity range Btu/h 2,050~ 11,250 3,400~ 13,000 2,050~ 10,900 3,400~ 13,000 4,090~ 18,400 5,100~25,200 7,500~ 36,000 7,500~ 36,000
EER2 Rating Btu/W.h 11.7 10.5 12.0 11.2 11.0 11.0 9.0 9.0
SEER2 Rating Btu/W.h 19.0 20.5 20.0 23.0 21.0 21.0 19.0 19.0
Rated Heating capacity (at 47°F) Btu/h 10,000 12,000 10,000 12,000 19,000 24,600 33,000 36,000
Rated Heating capacity (at 17°F) Btu/h 5,800 7,500 5,800 7,400 11,000 15,600 20,200 21,800
Heating capacity range Btu/h 2,050~ 12,200 3,400~ 13,900 2,050~ 12,200 3,400~ 13,900 4,090~ 19,000 5,100~ 25,900 7,500~ 36,000 7,500~ 36,000
HSPF2 Rating (Region IV) Btu/W.h 9.5 9.5 10.0 9.5 9.5 9.5 9.0 9.0
HSPF2 Rating (Region V) Btu/W.h 8.2 8.2 8.5 8.2 8.2 8.2 7.7 7.7
COP2 (at 47°F) W/W 3.81 3.41 3.81 3.41 3.41 3.41 3.15 3.15
Max. Heating capacity (at 5°F) Btu/h 7,300 8,500 7,200 8,500 12,500 16,400 20,400 20,400
Performance percentage (at 5°F) 73% 71% 74% 71% 66% 67% 57% 57%
COP2 (at 5°F) W/W 1.8 1.8 1.8 1.8 1.8 2.1 2.1 2.1
Max. Heating capcacity (at -4°F) Btu/h 6,100 7,200 6,100 7,200 11,000 14,600 18,800 18,800
Rated power consumption Cooling W 750 750 750 750 1,050 1,030 1,700 1,530
Rated power consumption Heating W 750 750 750 750 1,050 1,030 1,700 1,530
Rated power current Cooling A 3.4 3.4 3.4 3.4 4.7 4.8 7.7 6.9
Rated power current Heating A 3.4 3.4 3.4 3.4 4.7 4.8 7.7 6.9
Min. circuit ampacity A 6.8 6.8 4.7 4.8 7.7 8.2 14.0 15.2
Max. circuit breaker A 16 17 10 11 12 17 18 18
Moisture removal Pint/day 55 80 55 80 110 130 140 150
Refrigerant Type R454b (A2L rated refrigerant with a lower GWP rating of 466)
Refrigerant Amount Ozs 23.3 30.3 23.3 30.3 35.3 45.1 55.7 55.7
Sufficiency for max line set length Ft 25
Adjustment amount per feet Ozs 0.11
Recommended room size Sq.Ft 250~350 350~500 250~350 350~500 500~750 750~1,000 900~ 1,200 1,100~ 1,400
Minimum room size (unit height 6') SqF 26 34 26 34 40 51 63 63
Air volume CFM 342/270/235/200/152 342/270/235/200/152 342/270/235/200/152 342/270/235/200/152 617/575/511/411/382 847/705/588/470/412 847/705/588/470/412 847/705/588/470/412
Indoor sound level dB(A) 42/40/35/30/28 45/42/35/30/28 43/41/36/31/29 45/42/35/30/28 49/47/42/37/32 52/50/44/38/36 52/49/43/38/36 52/49/43/38/36
Outdoor sound dB(A) 54 55 54 55 55 58 63 63
Gas In (OD) 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 5/8" 5/8"
Liquid In (OD) 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4"
Standard line set length included Feet 16
Maximum allowable length Feet 50
Maximum allowable vertical run Feet 33
Indoor unit dimensions (WxDxH) Inch 31"-7/8 x 8" x 11"-1/2 31"-7/8 x 8" x 11"-1/2 31"-7/8 x 8" x 11"-1/2 31"-7/8 x 8" x 11"-1/2 34"-7/8 x 10"-3/4 x 14"-3/8 31" x 11"-1/2 x 19"-3/8 43"-1/8 x 11"-3/4 x 15"-3/8 46"-7/8 x 10"-1/4 x 14"-1/4
Indoor unit weight Lbs 19.8 19.8 19.8 19.8 27.6 36.4 39.7 39.7
Outdoor unit dimensions (WxDxH) Inch 33" x 13"-3/8 x 22"-3/4 33" x 13"-3/8 x 22"-3/4 33" x 13"-3/8 x 22"-3/4 33" x 13"-3/8 x 22"-3/4 34"-7/8 x 10"-3/4 x 14"-3/8 31" x 11"-1/2 x 19"-3/8 46"-7/8 x 10"-1/4 x 14"-1/4 49"-5/8 x 13" x 17"
Outdoor unit weight Lbs 51.8 55.1 51.8 55.1 55.1 55.1 48.5 48.5
Temperature setting range °F 62~86
Working ambient temperature range for cooling °F 5~122
Temperature setting range for heating °F -4~86

Note: Rated cooling performance data is based on standard ARI conditions of 80°F-DB/67°F-WB Indoor and 95°F Outdoor ambient conditions. Rated heating performance data is based on standard ARI conditions of 70°F-DB/60°F-WB Indoor and 47°F Outdoor ambient conditions. Variable speed inverter systems adjust their output capacity automatically based on actual indoor and outdoor temperatures, thermostat settings and other heating or cooling loads. Capacity of the system output and related power input will vary based on these conditions. System contains A2L refrigerant and the minimal room size data must be strictly adhered to for any standard installation to avoid fire risk. This data assumes the indoor unit installation height of minimum 6 feet from the floor level. Lower levels require larger min. room sizes. Specifications and data listed herein are subject to change without notice due to constant product and engineering improvements. Always refer to the equipment nameplate for applicable exact information.

PDF preview unavailable. Download the PDF instead.

5c3214ba-1192-436d-a748-d6dd79ecb495 Adobe PDF library 17.00

Related Documents

Preview Inverter Air Conditioner Service Manual - WYT Models
Comprehensive service manual for Inverter Air Conditioners, covering technical information, installation, maintenance, and troubleshooting for WYT models including WYT009, WYT012, WYT018, WYT024, WYT030, and WYT036 series.
Preview Pioneer Diamante Essenza Ductless Wall Mount Split Systems - WYT-17 Series
Explore the Pioneer Diamante Essenza WYT-17 series of ductless wall mount split systems, offering high efficiency, heat pump functionality, and DC inverter technology for single-zone applications. Details on features, specifications, and performance for various models.
Preview Pioneer WYT-20 Inverter Series Installation and User's Manual
Comprehensive installation and user's manual for the Pioneer WYT-20 Inverter Series Diamante Pro ductless mini-split air conditioning and heat pump systems. Covers safety precautions, system components, operating instructions, maintenance, installation, troubleshooting, and more.
Preview Pioneer Diamante ULTRA Multi-Zones: High-Efficiency Ductless Mini-Split Systems
Explore the Pioneer Diamante ULTRA Multi-Zones, a 20-23 SEER ultra-high efficiency heat pump system with DC inverter technology. This guide details standard features, accessories, and technical specifications for multi-zone ductless mini-split systems, including various indoor unit combinations.
Preview Pioneer YN009AMFI20RPD Heat Pump Energy Efficiency Guide (SEER & HSPF)
This Energy Guide label for the Pioneer YN009AMFI20RPD heat pump provides essential information on its cooling (SEER) and heating (HSPF) efficiency ratings. Learn about the product's performance range and where to find more energy cost information.
Preview Pioneer Diamante Ultra Ductless Mini-Split AC Heat Pump | Efficient & Quiet Operation
Discover the Pioneer Diamante Ultra, a high-efficiency, single-zone ductless mini-split AC heat pump system. It offers quiet operation, advanced features like self-cleaning and smart home integration, and robust performance in extreme temperatures, making it ideal for homes and offices.
Preview Pioneer HVAC Systems Product Catalog 2024
Comprehensive catalog detailing Pioneer's high-efficiency DC Inverter air conditioning and heating systems, including single-zone, multi-zone, ductless, and ducted units. Features detailed specifications, capacities, and energy efficiency ratings for various models.
Preview Pioneer WYS-20 Series Ductless Wall Mount Split Systems - High Efficiency Heat Pumps
Explore the Pioneer WYS-20 Series Ductless Wall Mount Split Systems, featuring high SEER/SEER2 ratings, DC inverter technology, and comprehensive features for efficient heating and cooling. View technical specifications and available accessories.