Dimplex Multidirectional Portable Air Conditioner

Instruction Manual

Models: DCP11MULTI & DCP14MULTI

For domestic household use only.

IMPORTANT

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Note also the information presented on the appliance.

CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/OR DAMAGE AND MAY INVALIDATE YOUR WARRANTY

Please read the operating instructions carefully before using your Portable Air Conditioner for the first time and keep them in a safe place.

WARNING – This appliance must not be used in a bathroom.

WARNING Do not use this appliance in the immediate surroundings of a bath, a shower or a swimming pool.

Safety Warnings (Visuals)

Specification

Model no. DCP11MULTI DCP14MULTI
Colour White/Black
Power supply 220-240V~, 50Hz
Operating temperature 5-35°C
Thermostat range 17-30°C
Rated Input Power 1.28kW 1.6kW
Cooling Capacity 3.2kW 4kW
Dehumidification Capacity (30°C, 80%RH) 50L/day 70L/day
Noise Level Minimum (Lo) 69dB(A) 70dB(A)
Noise Level Maximum (Hi) 70dB(A) 70dB(A)
Air Volume (lo/Med/Hi) 300/470/580 300/470/580
Refrigerant R410a
Fan speeds 3
Modes Sleep/Dry/Cool/Auto
Timer 0-24 hours
Dimensions (w x d x h) 335 x 538 x 765mm
Min room size 15m² 18m²
Max room size 23m² 26m²
Weight net 30.5kg 31kg
Weight gross 34kg 34.5kg

• For greater precision, please always refer to the rating label placed on the product.

Parts

The following parts are included with the unit:

Also included:

Control Panel

The control panel features the following buttons:

Indicator lights:

LED Display

Installation

PREPARATION

NOTE: All the illustrations in the manual are for explanatory purposes only. Your machine may be slightly different. The unit can be controlled by the control panel or with the remote control.

EXHAUST HOSE

The exhaust hose and adaptor must be installed or removed in accordance with the set FUNCTION. For COOL & DRY functions, the exhaust hose must be installed. For FAN only - the exhaust hose should be removed.

EXHAUSTING HOT AIR

In COOL function the appliance must be placed close to a window or opening so the warm exhaust air can be expelled outside.

CHOOSING THE RIGHT LOCATION

Your installation location should meet the following requirements:

Diagrams showing clearance requirements:

Vertical Installation:

A diagram shows the unit positioned near a window with an exhaust hose connected and extending out. The diagram indicates a minimum clearance of 500mm from the wall and 400mm from the top.

EXHAUST HOSE INSTALLATION

  1. Rotating the exhaust hose according to the direction in Fig (1) will remove the hose from the unit.
  2. Rotating the exhaust hose according to the direction in Fig (2) will attach the hose to the unit.
  3. Extend the exhaust hose to a length of no more than 400mm. The exhaust hose must be kept parallel and must not be bent up or down.

Diagrams showing exhaust hose attachment:

Figure (1) shows the hose being detached. Figure (2) shows the hose being attached.

NOTE: This unit has a self evaporative system which removes excess condensation by means of evaporating water collected in the tank. Therefore saving you the hassle of having to use a drip tray or drainage hose. Please make sure the rubber cap is locked into position to avoid any leakage.

NOTE: In high humidity areas, there may be excess water condensation produced that cannot be removed or evaporated. In this instance, the unit will need to be drained. View the WATER DRAINAGE section for details. The unit will automatically switch OFF when the internal water tank is full.

WINDOW KIT INSTALLATION

The window slider kit has been designed to fit most standard vertical and horizontal window applications, however it may be necessary for you to modify some aspects of the installation procedures for certain types of windows. The window slider kit can be fastened with screws (not supplied) if required.

Refer to Fig. 1 & Fig. 2 below:

Vertical Installation:

A diagram shows a window slider kit installed in a vertical window, with the exhaust hose connected to the unit and extending through the slider kit.

Horizontal Installation:

A diagram shows a window slider kit installed in a horizontal window, with the exhaust hose connected to the unit and extending through the slider kit.

Functions

POWER

Press the POWER button to turn the unit ON or OFF.

FUNCTION

Press the FUNCTION button to select between COOL, or DRY modes.

COOLING MODE

  1. The exhaust hose needs to be installed for this mode and the rubber cap should be fitted to the drainage hole.
  2. To set this mode, press the FUNC button until the COOL indicator light illuminates on the control panel.
  3. Set the target temperature between 17-30°C by pressing the increase (+) or decrease (-) buttons until the desired temperature is displayed on the LED display.

TIP: The most suitable temperature setting for a room during summer is 24°C.

DEHUMIDIFICATION MODE

  1. The exhaust hose & rubber cap needs to be removed for this mode, and a drain hose (not supplied) should be attached to the drainage hole.
  2. To set this mode, press the FUNCTION button until the DEHUM indicator light illuminates on the control panel.
  3. The fan speed is selected automatically by the unit and cannot be changed.

NOTE: Keep windows and doors closed for the best dehumidifying effect.

TEMP+/TEMP-

Press the TEMP+ button to increase the set temperature or press the TEMP- button to decrease the set temperature. The temperature can be set between 17-30°C.

NOTE: The time taken to reach the set temperature will depend on the environment and the size of the space in which the unit is operating in. For example, if the ambient temperature is too hot or the room is too large, the rate at which the temperature descends will be slow as the cooling may be less effective.

FAN SPEED

  1. The exhaust hose needs to be removed for this mode.
  2. Press the SPEED button to select either LOW, MEDIUM, HIGH or AUTO fan speeds.
  3. If AUTO fan speed is selected (during cooling mode) then either HIGH, MEDIUM or LOW speed will be selected automatically according to the difference between set temperature and ambient room temperature.

SWING

Press the SWING button to begin the automatic swing function. Press again to turn the SWING function off.

SETTING THE TIMER

A timer can be set to automatically turn the appliance ON or automatically turn it OFF.

To set the unit to automatically turn ON:
  1. While the unit is OFF press the TIMER button to set the desired time. The timer can be set in 1 hour increments up to 24 hours.
  2. After the TIMER has been set, choose what settings you'd like the unit to operate in.
  3. If the POWER button is pressed after completing the above, the timer will be cancelled.
To set the unit to automatically turn OFF:
  1. While the unit is running, press the TIMER button and set the desired time (between 1-24 hours) for the unit to remain ON, before automatically turning OFF.
  2. If the POWER button is pressed before the TIMER is up, it will cancel any TIMER set.

SLEEP MODE

Error Codes

Overheat Protection

This unit is fitted with an overheat prevention device. If the unit overheats it will automatically turn OFF. The unit can be restarted after 30 minutes.

Water Drainage

WATER DRAINAGE METHOD

When there is excess water condensation inside the Unit, the unit will stop running and the error code 'E4' will display. This indicates that the water needs to be drained using the following procedure:

Manual Drainage:
  1. Switch off and unplug the unit.
  2. Move the unit to a suitable location to drain the water. Consider placing a tray or suitable container under the outlet to catch any water.
  3. Remove the drain plug (2) refer to diagram.
  4. Slightly tilt the unit to the rear and drain the water out.
  5. Replace the drain plug before next use.

A diagram shows the rear of the unit with the drain plug labeled (2).

Remote Control

The remote control can be used to perform all functions. Refer to the below diagram and button description:

Using the Remote Control

  1. Open the battery cover of the remote control, and insert 2 x AAA batteries.
  2. Please point to the receiver and be within 5m when using the remote control.
  3. If the battery voltage is low, please open the battery cover as per the diagram and replace with new batteries (2 x AAA). Then replace the battery cover.

A diagram shows how to open the battery compartment and insert batteries.

A diagram shows a person pointing the remote control at the unit from a distance of up to 5m.

NOTE:

Cleaning

SAFETY PRECAUTIONS

AIR FILTERS

CAUTION: Never operate the unit without a filter in place.

A diagram shows the back of the unit with the air filters being removed.

Use a vacuum cleaner to remove dust from the filter. If further cleaning is required, the filter can be washed in lukewarm water (never hotter than 40 degrees). Ensure it is left to dry completely before reinstalling.

Outside Cabinet

  1. Remove any dust build up with a soft brush.
  2. Wipe the surface of the unit with a soft damp cloth. Mild detergent can be used for any stubborn marks.

Do not use abrasive sponges, scouring pads, or a stiff brush to clean the unit.

IMPORTANT

The control panel and other parts must not come into contact with water or any other liquids.

Maintenance

Storage

If not using the unit for an extended period of time, after cleaning please:

If the unit fails to operate efficiently, is broken or other problems arise, unplug and do not operate. Ask for advice by calling your local after sales service agent or the Customer Care Centre on 1300 556 816 (AU) / 0800 666 2824 (NZ).

Warranty

Please refer to the warranty card in the box for warranty information. For any troubleshooting advice, please contact the relative Customer Care Centre below.

Glen Dimplex Australia Pty Ltd

1340 Ferntree Gully Road,
Scoresby 3179, Victoria
Australia
Ph: 1300 556 816

Glen Dimplex New Zealand Ltd

38 Harris Road, East Tamaki,
Auckland 2013
New Zealand
Ph: 0800 666 2824

Recycling: Do not dispose of electrical appliances as unsorted municipal waste. Use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the ground water, polluting the food chain and damaging health and well-being.

Customer Care: 1300 556 816
customer.care@glendimplex.com.au
www.dimplex.com.au

Supplied by Glen Dimplex Australia
1340 Ferntree Gully Road, Scoresby, Victoria, 3179

© Glen Dimplex Australia. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex Australia.

PDF preview unavailable. Download the PDF instead.

Instructions - DCP11MULTI DCP14MULT Adobe PDF Library 15.0 Adobe InDesign 15.0 (Windows)

Related Documents

Preview Dimplex Multidirectional Portable Air Conditioner DCP11MULTI & DCP14MULTI Instruction Manual
Comprehensive instruction manual for the Dimplex Multidirectional Portable Air Conditioner, models DCP11MULTI and DCP14MULTI. Covers safety precautions, specifications, parts, control panel functions, installation, operation modes (Cooling, Dehumidification, Fan), timer, sleep mode, error codes, water drainage, remote control usage, cleaning, maintenance, and warranty information.
Preview Dimplex DC12, DC12RC, DC15 Portable Air Conditioner: User Manual & Guide
Comprehensive instruction manual for Dimplex DC12, DC12RC, and DC15 portable air conditioners. Covers installation, operation, controls, maintenance, troubleshooting, and technical specifications for optimal performance and user safety.
Preview Dimplex EWTC9 Portable Air Conditioner Instruction Manual
Comprehensive instruction manual for the Dimplex EWTC9 portable air conditioner, covering installation, operation, maintenance, troubleshooting, and specifications.
Preview Dimplex Portable Air Conditioner DCP12AN Instruction Manual
Comprehensive instruction manual for the Dimplex Portable Air Conditioner, Model DCP12AN. Covers safety precautions, installation, functions, troubleshooting, maintenance, and specifications.
Preview Dimplex DCP40FS Portable Air Conditioner with Wi-Fi Specifications
Technical specifications for the Dimplex DCP40FS, a 3.8kW recycled portable air conditioner with Wi-Fi connectivity, detailing cooling capacity, dimensions, features, and warranty.
Preview Dimplex DCP9BW 2.6kW Portable Air Conditioner Instruction Manual
Comprehensive instruction manual for the Dimplex DCP9BW 2.6kW Portable Air Conditioner, covering safety, installation, operation, functions, cleaning, maintenance, and troubleshooting.
Preview Dimplex Window/Wall Box Air Conditioner Instruction Manual - Models DCB05C, DCB07C, DCB09C, DCB07, DCB09, DCB14
Official instruction manual for Dimplex Window/Wall Box Air Conditioners. Includes detailed safety guidelines, installation steps, operation instructions, care and maintenance tips, electrical specifications, and troubleshooting for models DCB05C, DCB07C, DCB09C, DCB07, DCB09, and DCB14.
Preview Dimplex DCP16C Portable Air Conditioner Instruction Manual
Comprehensive instruction manual for the Dimplex DCP16C portable air conditioner, covering setup, operation, functions, safety, troubleshooting, and maintenance.