Instruction Manual for ARROW models including: CDC-15123-P1A Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions, CDC-15123-P1A, Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions, High Volume Infusions

linux, amd64

CDC-15123-P1A - Teleflex Incorporated - Vascular Access Product Catalog

PDF preview unavailable. Download the PDF instead.

LBL057039
6

NO

NO

CT

CT

CDC-15123-P1A

12 3 Fr.

Lumen

20cm catheter length

.035 inch dia. spring-wire guide

Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions

Contents:
1: Three-Lumen Catheter: 12 Fr. (4.06 mm OD) x 20 cm Pressure Injectable Radiopaque Polyurethane with Blue FlexTip®, Extension Line Clamps
1: Spring-Wire Guide, Marked: .035" (0.89 mm) dia. x 26-3/4" (68 cm) (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer
1: Catheter: 18 Ga. x 2-1/2" (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1: Injection Needle: SafetyGlideTM1 25 Ga. x 1" (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2" (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2" (6.35 cm) XTW and 5 mL Arrow®
Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2" (3.81 cm) and 5 mL Luer-Slip
Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with
Hi-Lite OrangeTM Tint 1: SharpsAway® Disposal Cup 1: SharpsAway® II Locking Disposal Cup

1: Maximal Barrier DrapeTM with 4" fenestration 1: Needle Holder 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Sterile Procedure Sign 1: Medication Label: 1% Lidocaine 2: Gauze Pad: 2" x 2" (5 cm x 5 cm) 5: Gauze Pad: 4" x 4" (10 cm x 10 cm) 1: Surgical Apparel: Impervious Gown 1: Surgical Apparel: Bouffant Cap 1: Surgical Apparel: Mask with Eye Shield 1: Suture: 3-0 Silk with Curved Needle 1: HemoHopper® Fluid Receptacle
1A trademark of Becton, Dickinson and Company. 2A registered trademark of CareFusion or one of its subsidiaries.

Not made with natural rubber latex. Store between 20 ­ 25°C (68 ­ 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications: The Multi-Lumen Acute Hemodialysis Catheter (AHDC) is not designed for long-term ( 30 days) hemodialysis or for insertion into thrombosed vessels.

LBL057039 R00 (2021-10)

