Instructions for Securitron models including: AQL Series Single Dual and Multi-Voltage Ready Intelligent Power System, AQL Series, Single Dual and Multi-Voltage Ready Intelligent Power System, Multi-Voltage Ready Intelligent Power System, Intelligent Power System, Power System
114 Power S securitron.com 800 626 590 customerservice.securitron@assaabloy.com Canada assaabloydss.ca 800 461 3007 sales.dss.ca@assaabloy.com Features Standard Features • Low battery cutoff protects batteries from deep discharge • Dedicated fast charger prolongs battery life • Enhanced surge immunity for input/output protection • LockSafe™ keeps locks cooler by
File Info : application/pdf, 2 Pages, 664.01KB
DocumentDocumentPower 114 AQL Series Single, dual & multi-voltage ready intelligent power system An out-of-the-box solution that offers unique performance and value. The AQL Series of switching power supplies is an out-of-the-box solution that makes installation easier. It is feature rich, network management ready and available in 12 or 24 VDC single, dual and multi-voltage units. Features Specifications Standard Features · Low battery cutoff protects batteries from deep discharge · Dedicated fast charger prolongs battery life · Enhanced surge immunity for input/output protection · LockSafeTM keeps locks cooler by providing a separate, dedicated battery charging circuit · OutSmartTM technology dual-color LED notification which prevents incorrect voltage application to locking devices [Green: 12 V | Blue: 24 V] · Auxiliary output rated 1.4 A continuous · Mix and match UL Listing · Instant auto-switch to battery on AC loss · Multi-voltage with B100 · Integrated Fire Alarm Interface (FAI) allows main output shutdown or disconnect on a per output basis when using an R8 output module · Network ready with optional NetlinkTM module · MagnaCare® lifetime replacement, no-fault, no questions asked warranty Optional Features · Enhanced Network Management - AC line voltage monitoring - Remote battery monitoring and testing - 1000 event data recording - Email fault reporting Certifications · UL 294 Listed · UL 603 Listed · UL 1076 Listed · ULC-S318 Listed · ULC-S319 Listed · CSA C22.2 #107.1 · RoHS Compliant Electrical · 12 VDC or 24 VDC output · 12 VDC & 24 VDC output (optional) with B100 · 120 or 230 VAC input · Up to 91% efficiency Environmental · Operating Temperature: 32° to 120° F [0° to 49° C] Max Shipping Weight · 15.50 lbs [7 kg] Dimensions · 14"H x 12"W x 4.5"D [355.6mm H x 304.8mm W x 114.3mm D] US securitron.com | 800 626 7590 | customerservice.securitron@assaabloy.com Canada assaabloydss.ca | 800 461 3007 | sales.dss.ca@assaabloy.com AQL Series Step by Step Configuration 115 Power Select One Power Supply Module 1 · AQL4 · AQL102 · AQL6 · AQL104 Select Required Modules* 2 · B100 · R8 · D8P · NL4 · D8 3 Choose Enclosure** · E1 Combine to Generate 4 Final Part Number Example: AQL4 - B100 + D8 + R8 + NL4 + E1 = AQL4-B100D8R8NL4E1 * When ordering more than one module, indicate quantity before the part number to generate final part number; for example AQL4-3D8E1. **No enclosure = Module PCB only. Each module may be ordered separately. Models MODELS AQL4* AQL6 AQL102 AQL104 AMPERAGE 4 3 6 10 10 RATED VOLTAGE 12 VDC 24 VDC 12 or 24 VDC 12 VDC 24 VDC INPUT VOLTAGE 120/230 VAC 120/230 VAC 120/230 VAC 120/230 VAC TYPICAL OUTPUT VOLTAGE 12.5 or 25 VDC 12.5 or 25 VDC 12.5 VDC 25 VDC MULTI-VOLTAGE READY Yes Yes Yes** Yes CLASS 2 OUTPUTS Yes with PTC distribution boards with PTC distribution boards with PTC distribution boards How to Order POWER SUPPLY MODULE SECONDARY VOLTAGE MODULE AQL4 -B100 DISTRIBUTION MODULE 2D8 *AQL4 is field selectable. **Multi-voltage of 5 to 9 VDC only D8 FUSE STYLE P RELAY MODULE R8 NETLINK MODULE NL4 ENCLOSURE E1 AQL4 (blank) (blank) (blank) 3 A ATM Fuse (blank) (blank) (blank) Module Only AQL6 B100 D8 P 2.5 A PTC Polyswitch R8 NL4 E1 AQL102 2D8 2R8 AQL104 3D8 3R8 4D8 5D8 6D8 AQL4 in an E1 enclosure has six module spaces where B100, NL4 and D8/D8P each take up one module space. R8 takes up two module spaces. AQL6, AQL102 and AQL104 in an E1 enclosure has four module spaces where B100 , NL4 and D8/D8P each take up one module space. R8 takes up two module spaces. Updated 1/11/22 Printed in the U.S.A. Patent pending and/or patent www.assaabloydss.com/patents Copyright © 2022, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Hanchett Entry Systems, Inc. is prohibited.