Installation Guide for SUSSEX models including: RBHS150RH, RBHS200RH, RBHS250RH, Circa Wall Bath Hostess System, RBHS150RH Circa Wall Bath Hostess System


File Info : application/pdf, 1 Pages, 387.02KB

PDF preview unavailable. Download the PDF instead.

SUSSEX CIRCA RBHS250RH wall bath hostess system 250 RH Installation Guide
Circa
Wall bath hostess system

1

"ROUGH-IN" View from above

NOGGING
THIS SIDE UP
OUTLET

WALL

STUD

90

IN-WALL BODY MASTERFIT

AS/NZS 3718:2005 LIC. 20081

28-32

Wall Covering 25mm

LOCKING SLEEVE

DRESS RING

HANDLE

1A

Pipe Connections

OUTLET

1/2" BSP
HOT IN

1/2" BSP
COLD IN

Product code

RBHS150RH RBHS200RH RBHS250RH

Wall bath hostess syst 150mm Wall bath hostess syst 200mm Wall bath hostess syst 250mm

RBHS150RH-V RBHS200RH-V RBHS250RH-V

Wall bath hostess syst 150mm - Vertex Wall bath hostess syst 200mm - Vertex Wall bath hostess syst 250mm - Vertex

Rough in plumbing (MASTERFIT) mounting guide
- The Masterfit will be supplied with the Spindles pre-installed. - Prepare a nogging and secure 28-32mm back from the front Using the screws (x4) of the stud (See Fig.1) - The Masterfit (in-wall) will be marked "This side Up" to Ensure the Masterfit is indicate orientation. - Using the screws (x4) provided, mount the Masterfit (in-wall) to the Nogging. - Ensure the Masterfit is level and square to the Wall Studs.
Pipe connections
- The Masterfit is supplied with coloured thread Caps to protect and identify the Hot and Cold inlet connections. - All lines must be free from any dirt and debris before connecting to the Masterfit. Flush all water feed lines. - Connect Hot and Cold lines to the corresponding 1/2" BSP ports of the Masterfit. (See Fig.1A) - Do not remove or disturb any factory fitted Pressure Plugs or Fixings. - Once all water connections are made, use the "Spindle Handle Adapter" and check Hot/Cold water operation. - Check all fittings and connections for leaks. - Store the Dress Kit in a safe place until required for Fit off.
Fitting off
- Seal the wall around the Locking Sleeve and immediately fit the Dress Ring. - Fit the Handle Body, the Handle Body must be fully engaged onto the Spindle; note the Set Screw contact point.
(See Fig.1B) - Secure the Handle body by tightening the Set screw using the 2mm Allen key provided. (Tighten well) - After completing the installation, establish water supply, check function of Tapware and ensure no water leaks.

sussextaps.com.au

AS/NZS 3718:2005 LIC. 20081
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003 Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.

