User Manual for SmartGen models including: CMM366B-4G Cloud Monitoring Communication Module, CMM366B-4G, Cloud Monitoring Communication Module, Communication Module, Module
SmartGen CMM366CAN-4G Cloud Monitoring Communication Module CAN interface. Cloud Monitoring Modules.Technical Parameters: WIFI/Ethernet/3G/2G 4G RS485 ● RS232 ● LINK ● CAN ● USB Device B-type USB female port USB Host A-type USB female port GPS Antenna Interface ● GPRS Antenna Interface ● Installation Method Railway/screw fixing DC Supply DC(8-35)V Case Dimensions(mm) 72.5*105*34(mm) Operating Temp. (-25~ 70)℃ Net Weight(kg) 0.15 Product Overview: CMM366B-4G/CMM366CAN-4G Cloud Monitoring Communication Modu
SmartGen CMM366B-4G 4G Cloud Monitoring Communication Module. Cloud Monitoring Modules.Technical Parameters: WIFI/Ethernet/3G/2G 4G RS485 ● RS232 ● LINK ● USB Device B-type USB female port USB Host A-type USB female port GPS Antenna Interface ● GPRS Antenna Interface ● Installation Method Railway/screw fixing DC Supply DC(8-35)V Case Dimensions(mm) 72.5*105*34(mm) Operating Temp. (-25~ 70)℃ Net Weight(kg) 0.15 Product Overview: CMM366B-4G/CMM366CAN-4G Cloud Monitoring Communication Module is 4G wireless net
File Info : application/pdf, 18 Pages, 1.59MB
DocumentDocumentCMM366B-4G/CMM366CAN-4G CLOUD MONITORING COMMUNICATION MODULE USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen -- make your generator smart SmartGen Technology Co., Ltd. No.28 Jinsuo Road, Zhengzhou, Henan Province, China Tel: +86-371-67988888/67981888/67992951 +86-371-67981000(overseas) Fax: +86-371-67992952 Web: www.smartgen.com.cn/ www.smartgen.cn/ Email: sales@smartgen.cn All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder. Applications for the copyright holder's written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. SmartGen Technology reserves the right to change the contents of this document without prior notice. Date 2020-03-10 2020-05-15 2020-08-04 2021-06-07 2021-10-21 Version 1.0 1.1 1.2 1.3 1.4 Table 1 Software Version Note Original release. Fix Fig. 14 Unit from cm to mm. Fix Fig. 6 Link interface communication line according to the real Figure. 1. Apply the latest user manual format; 2. Change font from Arial to Roboto; 3. Modify APP installation steps; 4. Change the app download QR code of CMM366B-4G mask. 1. Modify Fig.1 Panel Indicator; 2. Add 2 notes in 4.4 SIM Card Installation. CMM366B-4G/CAN-4G Cloud Monitoring Communication Module User Manual Page 2 of 18 CONTENT 1 OVERVIEW................................................................................................................................................. 4 2 PERFORMANCE AND CHARACTERISTICS.............................................................................................. 4 3 SPECIFICATION ........................................................................................................................................ 5 4 PANEL AND TERMINAL DESCRIPTION ................................................................................................... 6 4.1 PANEL INDICATOR AND KEYS ........................................................................................................... 6 4.2 GPRS/4G ANTENNA PORT ................................................................................................................. 7 4.3 GPS ANTENNA PORT.......................................................................................................................... 7 4.4 SIM CARD INSTALLATION.................................................................................................................. 7 4.5 RS485 PORT ........................................................................................................................................ 8 4.6 RS232 PORT ........................................................................................................................................ 8 4.7 LINK PORT ........................................................................................................................................... 9 4.8 USB HOST PORT.................................................................................................................................. 9 4.9 USB DEVICE PORT............................................................................................................................. 10 4.10 CAN PORT.......................................................................................................................................... 10 4.11 TERMINALS ....................................................................................................................................... 11 5 PROGRAMMABLE PARAMETERS.......................................................................................................... 12 5.1 CONTENTS AND SCOPES OF PARAMETERS .................................................................................. 12 5.2 PC CONFIGURATION INTERFACE .................................................................................................... 13 6 SYSTEM APPLICATION DIAGRAM ........................................................................................................ 14 7 CASE DIMENSION AND INSTALLATION ............................................................................................... 14 8 APP INSTALLATION STEPS................................................................................................................... 16 9 FAULT FINDING ...................................................................................................................................... 17 10 PACKING LIST....................................................................................................................................... 18 11 APPENDIX (ORDER MODEL) ................................................................................................................ 18 CMM366B-4G/CAN-4G Cloud Monitoring Communication Module User Manual Page 3 of 18 1 OVERVIEW CMM366B-4G/CMM366CAN-4G Cloud Monitoring Communication Module is 4G wireless network communication protocol conversion module of all-modes, which can achieve genset (with SCI) connection with Internet. After logging into cloud server, module will receive corresponding genset controller communication protocol from cloud server. Cloud monitoring module can obtain genset data information via RS485, USB, LINK, CAN, or RS232 port, and send the information to related could server via 4G wireless network. Users can monitor genset running status at real time and check genset running records by mobile APP (IOS or Android), or PC etc. terminal device. It not only can realize genset monitoring, but also can be connected with some digital alarm inputs, to realize monitoring of genset entrance guard, prevention of burglary, fire control etc. ancillary facilities. It has GPS positioning function, which can upload the obtained longitude and latitude, altitude information at real time to the corresponding cloud server. CMM366CAN-4G cloud monitoring communication module has CAN port, but CMM366B-4G hasn't. Except for this, these two cloud monitoring communication modules has same functions. 2 PERFORMANCE AND CHARACTERISTICS Connect to cloud server via 4G wireless network, one cloud monitoring module for one genset; Multiple communicating ports with genset control module: RS485, RS232, LINK, CAN port, USB (Host), which can monitor most genset control modules of leading brands internationally; Wide power supply: DC (8~35)V, which can directly use engine build-in starting battery; With ARM-based 32-bit SCM, high integration of system and strong programming ability; GPS positioning function for obtaining genset location information, to realize genset positioning; Apply network data communication protocol of JSON format, upload the genset data changes at real time, meanwhile compression algorithm is applied, which extremely reduces network flow; Immediately upload the data to cloud server when genset alarms occur; Event log memory function, which can ensure data won't get lost when network is not steady; Cloud Modem can be upgraded by 4G network, convenient for module' s maintenance; 2 configurable digital input ports, which can be connected with external alarm signals; Module panel has power and multiple communication status indicators; clear display module working status; Lamp test function; Parameter setting function: users can do parameter setting by module USB port; Apply standard -type 35mm guide-rail installation or screw-fixed installation, and the module can be installed in the genset control box; Modular structure design, flame retardant ABS enclosure, light weight, compact structure with easy installation. CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 4 of 18 3 SPECIFICATION Items Operating Voltage Power Consumption Digital Input USB Host RS485 Port RS232 LINK USB Device CAN Port GPRS Port GPS Port Wireless Network Case Dimensions Working Temperature Working Humidity Storage Temperature Weight Table 2 Technical Data Contents DC8.0V~35.0V, continuous power supply. Standby: 2W Working: 5W Digital Input, connect (B-) is active. A-type USB female port Isolated type General type SmartGen exclusive port B-type USB female port Isolated type Standard SMA port (female), SMA port (male) for antenna. Standard SMA port (female), SMA port (male) for antenna, active antenna. LTE-TDD/LTE-FDD/HSPA+/TD-SCDMA/EVDO GSM/GPRS/EDGE 72.5mmx105mmx34mm (-25~+70)°C (20~93)%RH (-30~+80)°C 0.15kg CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 5 of 18 4 PANEL AND TERMINAL DESCRIPTION 4.1 PANEL INDICATOR AND KEYS Icon POWER/ALARM RS485 (Red) USB (Red) GPS (Red) RS232/LINK (Red) CAN (Red) GPRS/4G (Red) Fig. 1 Panel Indicator Table 3 Indicators Description Note Green LED Light On: Power supply normal indicator; Red LED Light On: Common alarm indicator. Normally Light Off: RS485 disabled; Normally Light On: Communication failed; Flash: Communication normal. Normally Light Off: USB(Host) disabled; Normally Light On: Communication failed; Flash: Communication normal. Normally Light Off: GPS disabled; Normally Light On: GPS not gained satellite signal; Flash: GPS gained satellite signal. Normally Light Off: RS232/LINK Disabled; Normally Light On: Communication failed; Flash: Communication normal. Normally Light Off: CAN disabled; Normally Light On: Communication failed; Flash: Communication normal. Normally Light Off: 4G module logins with server unsuccessfully; Normally Light On: Login with server successfully; Flash: Real-time communication normal. CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 6 of 18 Internal Lamp Test/Reset Key: Press and hold this key for 1s, all the LEDs are illuminated; press and hold for 10s, recover default configurations of CMM366B-4G/CMM366CAN-4G and all LEDs flash for 3 times. NOTE: After reset the module, parameters need to be re-configured via PC software or mobile APP. Please operate cautiously. 4.2 GPRS/4G ANTENNA PORT Connect GPRS antenna to GRRS/4G port. Antenna port: 50/SMA female. 4.3 GPS ANTENNA PORT GPS enabled, connect GPS antenna to CMM366B-4G/CMM366CAN-4G. NOTE: GPS antenna needs to be placed to open outdoors, otherwise location information may not be accurate or cannot be gained. Antenna port: 50/SMA female, active antenna. Fig. 2 CMM366B-4G/CMM366CAN-4G Antenna Connection NOTE: GPRS antenna and GPS antenna cannot be connected reversely. 4.4 SIM CARD INSTALLATION Insert 4G SIM card. CMM366B-4G/CMM366CAN-4G will connect to server via wireless mobile network. NOTE: This module supports 4G wireless network of all modes. Standard SIM card is applied (size: 25mmx15mm); GPS indicator and GPRS indicator flash at the same time means SIM card is not inserted or SIM card is in bad contact. After removing the head cover, the installation steps are as below: CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 7 of 18 Fig. 3 SIM Card Installation Steps NOTE: IMEI number can be viewed from the controller side. NOTE: One card for one controller, the same card can't be removed from a module and inserted into another module, which will affect the normal use. 4.5 RS485 PORT Receive genset data information by connecting RS485 port with genset controller RS485 port. 120 terminal resistor is recommonded, and short connect RS485 A(+) and TR terminal. Fig. 4 RS485 Connection Diagram 4.6 RS232 PORT Receive genset data information by connecting RS232 port with genset controller RS232 port. Fig. 5 RS232 Connection Diagram CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 8 of 18 4.7 LINK PORT Receive genset data information by connecting LINK port with genset controller LINK port. Fig. 6 LINK Connection Diagram 4.8 USB HOST PORT Receive genset data information by connecting A-type USB port (female) with genset controller USB port via USB cable. Fig. 7 USB Host Connection Diagram CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 9 of 18 4.9 USB DEVICE PORT All the parameters can be configured and view CMM366B-4G/CMM366CAN-4G module ID&Login password by connecting USB port with PC. Fig. 8 USB and PC Device Connection Diagram Fig. 9 USB and SGB100 Module Connection Diagram 4.10 CAN PORT CMM366CAN-4G model has this function. Obtain genset data information by connecting CAN port and genset CAN port. 120 terminal resistor is recommended and short connect CANH and TR terminal. Fig. 10 CAN Connection Diagram CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 10 of 18 4.11 TERMINALS No. 1 B- Function 2 B+ 3 Digital Input 1 4 Digital Input 2 5 CANL 6 CANH 7 TR 8 RS485 B(-) 9 RS485 A(+) 10 TR 11 RS232 RX 12 RS232 TX 13 RS232 GND Table 4 Terminals Description Cable Size 1.0mm2 1.0mm2 1.0mm2 1.0mm2 0.5mm2 0.5mm2 0.5mm2 0.5mm2 0.5mm2 0.5mm2 0.5mm2 0.5mm2 0.5mm2 Note Connected with negative of starter battery. Connected with positive of starter battery. 3A fuse is recommended. Active when connect to B-. Active when connect to B-. 120 terminal resistor is recommended, short connect CANH and TR terminal. 120 terminal resistor is recommended, short connect RS485 A(+) and TR terminal. RS232 port. CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 11 of 18 5 PROGRAMMABLE PARAMETERS 5.1 CONTENTS AND SCOPES OF PARAMETERS Table 5 Parameter Contents & Scopes No. Gateway Items 1 Site Name 2 Server URL 3 Server Port 4 Security Code GPS 1 GPS Enabled Parameters (0-65535) (0-1) Defaults Description 20 Chinese characters, letters or numbers. www.smartgencloudplus.com 40 characters 21318 123456 16 characters 1 0: Manual Input 1: GPS Location 2 Longitude 3 Latitude 4 Altitude Digital Inputs Digital Input 1 1 Setting 2 Type 3 Delay Digital Input 2 1 Setting 2 Type 3 Delay ((-180)-180)° ((-90)-90)° ((-9999.9)-9999.9)m 113.554879 34.802335 100.0 GPS location, altitude information. (0-9) (0-1) (0-20.0) (0-9) (0-1) (0-20.0) 0 Default: Not used. 0: Active when close; 1: Active when open. 0 See: Table 6 Digital Input Ports Content. 0.0 Action delay. 1 Default: Lamp test. 0: Active when close; 0 1: Active when open. See: Table 6 Digital Input Ports Content. 0.0 Action delay. NOTE: Monitoring genset controller model, communication port, communication baud rate, and communication ID need to be set on the platform, and cloud monitoring module needs to re-power after all parameters being set. CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 12 of 18 Table 6 Digital Input Ports Content No. Item 0 Not Used 1 Lamp Test 2 Remote Control Inhibited 3 Access Alarm Input 4 Fire Alarm Input 5 Alarm Input 6 Reserved 7 Reserved 8 Reserved 9 Factory Test Mode Description Not used. All the indicators are illuminated when input is active. Cloud start/stop control is prohibited when input is active. Access alarm is uploaded to server when input is active. Fire alarm is uploaded to server when input is active. External alarm is uploaded to server when input is active. It is only used for factory test. 5.2 PC CONFIGURATION INTERFACE Connecting the USB port of CMM366B-4G/CMM366CAN-4G communication module with PC to configure the parameters. Fig. 11 Gateway Configuration Fig. 12 Module Monitoring Interface CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 13 of 18 6 SYSTEM APPLICATION DIAGRAM One CMM366B-4G/CMM366CAN-4G module connects with one genset monitoring module. It can be connected via RS485 port, LINK port, CAN port, RS232 port or USB port. Fig. 13 CMM366B-4G/CMM366CAN-4G System Application Diagram 7 CASE DIMENSION AND INSTALLATION 35mm guide rail cabinet installation or screw-fixed (M4) installation can be applied. Case dimensions are as below: Unit: mm Fig.14 CMM366B-4G/CMM366CAN-4G Case Dimension CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 14 of 18 Fig.15 CMM366B-4G/CMM366CAN-4G Guide Rail Installation Fig.16 CMM366B-4G/CMM366CAN-4G Screw Installation CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 15 of 18 8 APP INSTALLATION STEPS Fig. 17 APP Download QR Code 1) Scan the QR code on the enclosure of CMM366B-4G/CMM366CAN-4G cloud monitoring communication module (QR code is as Fig. 17), download the APP and install it in the mobile; 2) Open the APP from the mobile, users have to register for the first using, then input account number and password to enter APP; 3) Other related settings please refer to "Me-Guidance" (as Fig. 18). Fig. 18 APP Display Interface CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 16 of 18 9 FAULT FINDING Table 7 Fault Finding Symptoms Module No Response with Power GPRS/4G Indicator Off GPS Not Gain Location RS485 Comm. Abnormal RS232 Comm. Abnormal LINK Comm. Abnormal CAN Comm. Abnormal USB(Host) Comm. Abnormal Possible Solutions Check power voltage; Check module connection wirings. Check SIM card is inserted or not; Check GPRS antenna is connected or not. Check GPS parameters are enabled or not; Check GPS antenna is connected or not and placed outdoor or not. Check connections; Check RS485 port is enabled or not on cloud server platform communication port; Check settings of genset ID and baud rate are correct or not. Check RS485's connections of A and B is reversely connected or not. Check connections; Check RS232 port is enabled or not on cloud server platform communication port; Check settings of genset ID and baud rate are correct or not. Check connections; Check LINK port is enabled or not on cloud server platform communication port; Check settings of genset ID and baud rate are correct or not. Check connections; Check CAN port is enabled or not on cloud server platform communication port; Check communication baud rate is correct or not; Check CANL and CANH are reversely connected or not; Check genset controller ID is correct or not. Check connections; Check USB port is enabled or not on cloud server platform communication port; Check genset controller ID is correct or not. CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 17 of 18 10 PACKING LIST Table 8 Packing List No. Name 1 Cloud Monitoring Communication Module 2 4G+GPS/BD Two-in-one Antenna 3 Certification 4 User Manual 5 SIM Card Tray 6 RS485 Communication Cable Quantity 1 1 1 1 1 1 Remark CMM366CAN-4G (with CAN port) CMM366B-4G (without CAN port) Length: 50cm 11 APPENDIX (ORDER MODEL) Table 9 CMM366B-4G/CMM366CAN-4G Order Model Order Model CMM366B-4G CMM366CAN-4G CMM366B-4G-S01 CMM366CAN-4G-S01 CMM366B-4G-S04 CMM366CAN-4G-S04 CMM366B-4G-S02 CMM366CAN-4G-S02 CMM366B-4G-S03 CMM366CAN-4G-S03 CMM366B-4G-S05 CMM366CAN-4G-S05 Country/Area Chinese Mainland North America Frequency Band FDD-LTE: B1/B3/B8 TDD-LTE: B38/B39/B40/B41 TD-SCDMA: B34/B39 WCDMA: B1/B8 EVDO/CDMA: BC0 GSM: 900/1800MHz FDD-LTE: B2/B4/B12 WCDMA: B2/B5 FDD-LTE: B2/B4/B5/B13 Europe/Africa/ South Korea/Thailand/ Middle East South America/ Australia/ New Zealand FDD-LTE: B1/B3/B5/B7/B8/B20 TDD-LTE: B38/B40/B41 WCDMA: B1/B5/B8 GSM: 900/1800MHz FDD-LTE: B1/B2/B3/B4/B5/B7/B8/B28 TDD-LTE: B40 WCDMA: B1/B2/B5/B8 GSM: 850/900/1800/1900MHz Japan FDD-LTE: B1/B3/B8/B18/B19/B26 Remark _____________________________________ CMM366B-4G/366CAN-4G Cloud Monitoring Communication Module User Manual Page 18 of 18