User Manual for Nature Power models including: Power Inverter 750 Watt, 37750

300W Manual

User Manual - Northern Tool

This manual contains important safety and operating instructions for power inverter 750W .This manual will show you how to use your inverter safely and effectively. Please read, understand and follow these instructions and precautions carefully. 2. Keep out of reach of children. 3. Do not expose inverter to rain or snow. 4. Use of an attachment ...

Product Manual - Northern Tool

... 750 Watt Power Inverter. User Manual. V1.1-M 13Apri2020. SAVE THESE INSTRUCTIONS. WARNING Read carefully and understand all ASSEMBLY AND​.


File Info : application/pdf, 12 Pages, 3.03MB

PDF preview unavailable. Download the PDF instead.

88428
User Manual

V1.1-M 13Apri2020

WARNING Read carefully and understand all ASSEMBLY AND OPERATIONINSTRUCTIONS before operating. Failure to follow the safety rules and other basic safetyprecautions may result in serious personal injury.
Item #37750 SAVE THESE INSTRUCTIONS

T an you for c oosin a Nature Po er Pro uct This product is designed for certain applications only. he distributor cannot be responsible for issues arising from modification. We strongly recommend this product not be modified and/or used for any application other than that for which it was designed. If you have a question relative to a particular application, o not use the product until you have first contacted the distributor to determine if it can or should be performed on the product. For technical question please call 1 800-588-0590

Reference 1
2

PAR I
Part Description t

ct

t tt

ct

t 2

Quantity 1
1 2 1

WARNING
This product can expose you to chemicals, including Di (2-ethylhexyl) phthalate (DEHP) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information, go to www.p65warnings.ca.gov
A R N IA
Este producto puede exponerlo a productos u micos, incluidos Di (2-etilhexil) ftalato (DEHP) ue el estado de California sabe ue causa c ncer, defectos de nacimiento u otros da os
reproductivos. Para obtener m s informaci n, vaya a www.p65warnings.ca.gov

Page 2 of 12

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS.

1. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions for power inverter 750W.This manual will show you how to use your inverter safely and effectively. Please read, understand and follow these instructions and precautions carefully.
2. Keep out of reach of children. 3. Do not expose inverter to rain or snow. 4. Use of an attachment not recommended
or sold by the unit manufacturer may
injury to persons. 5. Do not disassemble the unit; take it to
repair is required. Incorrect reassembly
6. To reduce risk of electric shock, unplug unit from outlet before attempting any

maintenance or cleaning. Turning off controls will not reduce this risk. 7. For the most effective use, place the power inverter on a flat surface. 8. Do not place the inverter on or near heating vents, radiators or other sources
9. Do not place the inverter in direct sunlight. The ideal air temperature for operation is between 50° and 80°F.
10. Only connect the power inverter to a 12V battery or power supply. Do not attempt to connect the inverter to any other power source, including an AC power source. Connecting to a 6V or 16V battery will cause damage to the inverter.
11. Do not use the inverter with a product that draws a higher wattage than the inverter can provide, as this may cause damage to the inverter and product.

Page 3 of 12

A
· ON/OFF rocker switch
· LED indicator Green indicates Power ON Red indicates Overload/Interruption in power
· 12 Volt power cord
· 120V standard AC outlets x2 · USB port ­ 5V, 2.0A

R
· High-speed cooling fan To keep the inverter cool, the fan turn on depend on the load on the inverter or temperature in the inverter. The fans do not run when the inverter is turned off.
· Positive Battery Cable Terminal (Red)
· Negative Battery Cable Terminal (Black)

CONNECTING INVERTER CA ES

The inverter and power source must be in 3. Place the POSITIVE (RED) ring

the OFF mode.

connector onto the POSITIVE

IMPORTANT: Make sure to connect your inverter only to a 12 volt power supply.

(RED) inverter terminal. Place the NEGATIVE (BLACK) ring connector

onto the NEGATIVE (BLACK)

CONNECTING INVERTER CABLES TO

inverter terminal.

THE INVERTER

4.

1. Locate the Positive and Negative terminals on the right side of the inverter

top of each ring connector. Put a hex nut over these and tighten.

2. From the POSITIVE (RED) and the NEGATIVE (BLACK) terminals, remove

Page  of 12

+

-

Page  of 12

P RA ING IN R I N

. Connect the inverter (see Connecting Inverter Cables section).
. Switch the inverter's ON/OFF switch to the ON (I) position.
. The GREEN LED indicator will light, indicating the inverter is receiving power.
. Switch the inverter's ON/OFF switch to the OFF (O) position. (The reen ED

5. Make sure the device to be operated is turned OFF.
6. Plug the device into the inverter's AC outlet.
7. Switch the inverter's ON/OFF switch to the ON (I) position.
8. Turn the device on. 9. To disconnect, reverse the above
procedure.

may flash briefly and or the internal

speaker may make a brief "beep". This

is normal.)

Page  of 12

NOTE: If more than one device is to be powered, start one device at a time, to avoid a power surge and overloading the inverter. The surge load of each device should not exceed the inverter's continuous peration wattage rate. IMPORTANT: Using the inverter with some rechargeable devices may

damage the inverter and/or device. If you are using the inverter to operate a rechargeable device, monitor the temperature of the inverter for about 10 minutes. If the inverter becomes abnormally hot, disconnect it from the device immediately; do not use the device with the inverter.

POWER SOURCE

Your average automobile battery at full charge will provide an ample power supply to the inverter when the engine is on. Keep the car running at all times when using the inverter. The actual length of time the inverter will function depends on the age and condition of the battery and the power demand being placed by the device being operated with the inverter.
When possible, recharge your batteries when they are not more than 50% discharged. This gives the batteries a much longer life cycle than recharging when they are more deeply discharged.

The power inverter has a battery low voltage shutdown at 10V±0.5V DC. With moderate to heavy loads, this will protect against over-discharging the battery. If the inverter is running only light loads it is advisable to recharge before the inverter low voltage shutdown point is reached.
IMPORTANT: The inverter draws low amperage from the battery with the main ON/OFF switch turned on and no load connected. To prevent battery discharge, turn the inverter off when you are not using it.

Page  of 12

LED INDICATOR AND SHUTDOWN PROTECTION

The Green LED lights automatically when the inverter is plugged into a 12 volt DC power source and is turned on. The Red LED lights, the alarm sounds and the inverter automatically turns itself off under the following conditions:
1. When the power input from the vehicle's battery drops to approximately 10.5 volts, the low voltage alarm will sound. When the voltage goes down below 10 VDC, the inverter shuts off. Recharge or replace the battery.
2. When the power input from the vehicle's battery exceeds 16 volts, high voltage protection occurs.

3. The continuous load demand from the equipment or device being operated exceeds the continuous load rating of the inverter. Use a higher capacity inverter or lower rated device.
4. The thermal resistor exceeds 80° C (176° F.) Allow the inverter to cool. Do not block the cooling slots or inverter Reduce the load on the inverter to the continuous rated output.
RESET: To reset after shutdown occurs, switch the inverter's ON/OFF switch to the OFF (O) position. Check the source of the problem and correct. Switch the inverter's ON/OFF switch to the ON (I) position.

IF THE INVERTER'S FUSE BLOWS

i which should not have to be replaced under normal operating conditions. A blown fuse is usually caused by reverse

polarity or a short circuit within the device or equipment being operated.
If a fuse does blow, take the inverter to

Page  of 12

MAINTENANCE AND STORAGE INSTRUCTIONS

1. Before each use, ensure that all of the inverter's components are in place and in good working condition.
2. After use and before performing maintenance, unplug and disconnect the inverter.
3. Use a clean, dry cloth to wipe external surfaces of the inverter's case.

4. Servicing does not require opening the unit, as there are no user-serviceable parts. All servicing should be performed
5. Store inside, in a cool, dry place, out of the reach of children.
6. Recycle or properly dispose of internal electrical components.

Page  of 12

TROUBLESHOOTING

PROBLEM
Red LED is on, alarm sounds, and/or inverter does not function.

POSSIBLE CAUSE Poor contact at terminals.

REASON/SOLUTION
Check for poor connection to battery or power supply. Make sure connection points are clean. Rock clamps back and forth for a better connection.

Connections are reversed. Unplug the inverter and reverse the clamps.

Fuse is blown.

See inverter Fuse B

ct

Over voltage protection Overload protection

See LED Indicator and Shutdown Protection section.

Device does not

The inverter may not

Turn the inverter switch OFF

operate properly

have the required capacity and ON, to reset the inverter. If

when first connected to operate the device. to the inverter.

device still does not operate, the inverter should not be used with this device. Use a higher capacity

inverter or lower rated device.

Page  of 12

SPECIFICATIONS
Nominal input voltage ................................................................................. 12.8-13.2 VDC Nominal output voltage ...................................................................................115±10 VAC Output frequency ............................................................................................. 60 Hz±3 Hz Operating input voltage ............................................................................... 10.0-15.0 VDC Continuous output power ................................................................................ Up to 750 W Surge output power ................................................................................................1500 W Waveform .............................................................................................. Typical Effciency (at nominal input voltage) ............................................................. 86% Typical No Load Current (at nominal input voltage) .............................................. 0.5 ADC Input overvoltage shutdown ..........................................................................15.5±0.5 VDC Input undervoltage alarm ..............................................................................10.5±0.5 VDC Input low voltage shutdown...........................................................................10.0±0.5 VDC Output power overload shutdown level............................................................. 850±100 W External fuse ........................................................................................................... 40A x 2 AC receptacles................................................................................. . . 2x NEMA 5-15 USA USB port ......................................................................................................... . One, 5V/2A Cable with battery clamps ............................................................................ 8AWG, 2x23'' Cable with 12V car plug................................................................................ 16AWG,1x21''
Page  of 12

LIMITED WARRANTY

Nature Power warrants our products to the original purchaser that this product is free from

defects in materials and workmanship for the period of one year from date of purchase. In

the case of product defect, contact Nature Power customer service to receive

troubleshooting. If defective part or unit should be returned, a Return Authorization

Number must be issued by Nature Power and the defective part or unit should be returned

to the authorized location at the purchasers' expense. A dated proof of purchase is

required to receive warranty service. Once received at authorized location and defect

proves to be the result of defective material and workmanship, the defective part or unit

will be replaced at warrantors' option and returned to the original purchaser at warrantors'

expense. No refunds will be granted by the warrantor, t

t

c t ct

t

c

t t

t

c

Please contact Nature Power Products to acquire more information: 1-800-588-0590
info@naturepowerproducts.com www.naturepowerproducts.com
Made in Taiwan
Page 2 of 12



References