User Guide for KEITHLEY models including: 4200 ACS Standard Edition, 4200, ACS Standard Edition, Standard Edition, Edition
ACS Software Standard Version 6.3 with WLR edition | Tektronix
Issue number: ACS-688. Symptom: ACS cannot scan the Matrix 707B with 7072B cards in the hardware management tool. Resolution: This issue has ...
File Info : application/pdf, 14 Pages, 1.63MB
DocumentDocumentKeithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-833-9200 tek.com/keithley ACS Standard Edition Version 6.3 Release Notes Contents General information.....................................................................................................................1 Supported operating systems ....................................................................................................1 ACS Standard revision history ...................................................................................................2 Install ACS ...................................................................................................................................2 Supported models and test configurations ...............................................................................5 Supported communications interface........................................................................................7 Software license ..........................................................................................................................8 License management ..................................................................................................................8 ACS Standard version 6.3 ...........................................................................................................9 GENERAL INFORMATION This document describes the features added to the Keithley Instruments Automation Characterization Suite (ACS) Standard Edition software (version 6.3). The Keithley Instruments ACS Standard Edition software supports component characterization testing of packaged parts and wafer-level testing using probers. ACS Standard Edition software can be installed on any computer, including the Keithley Instruments Model 4200A-SCS Parameter Analyzer and Model 4200A Semiconductor Characterization System (4200-SCS). SUPPORTED OPERATING SYSTEMS ACS Standard Edition software is supported on the following operating systems: Microsoft® Windows® 11, 64-bit Microsoft Windows 10, 64-bit Microsoft Windows 10, 32-bit Microsoft Windows 7, 64-bit (with Service pack 1) Microsoft Windows 7, 32-bit (with Service pack 1) PA-1008 Rev. U November 2023 *PA-1008U* 1 ACS Standard Edition Version 6.3 Release Notes ACS STANDARD REVISION HISTORY Version 6.3 6.2 6.1 6.0 5.4 5.3 5.2.1 5.2 5.1 5.0 4.4 4.3.1 4.3 4.2.5 4.2 Release date November 2023 November 2022 March 2022 August 2021 February 2021 December 2017 September 2015 December 2014 May 2014 February 2013 December 2011 June 2011 March 2011 October 2010 June 2010 INSTALL ACS To install ACS software on a personal computer or 4200A-SCS: 1. Log in to your computer as an Administrator. 2. Open the ACS executable file. 3. Follow the software installation instructions. 4. Select Yes if you have an older version of ACS installed, as shown in the following figure. Figure 1: ACS Software installation 5. Follow the instructions to specify how you want to install the software on your system. 6. If you have projects you need to backup or restore from a previous version of ACS, see the following Update previous versions of ACS files. 2 PA-1008 Rev. U November 2023 ACS Standard Edition Version 6.3 Release Notes INSTALL ACS ON A 4200A-SCS PARAMETER ANALYZER If you are installing ACS on a 4200A-SCS Parameter Analyzer, the following dialog box is displayed, indicating the applications identified are needed for installation. Make sure you select Do not close applications and Next to install (see the following figure). Figure 2: ACS 6.3 prepare to install UPDATE PREVIOUS VERSIONS OF ACS FILES Once ACS is installed, you can use the UpgradeTool.exe to convert your ACS 6.0 files or later to the current version, which includes projects, libraries, and settings from previous versions. To update previous software files: 1. Go to C:\ACS\UpgradeTool\. 2. Double-click UpgradeTool.exe. 3. Choose the items in the folder you want to update (see the following figure). PA-1008 Rev. U November 2023 3 ACS Standard Edition Version 6.3 Release Notes Figure 3: ACS Software installation 4. 5. Select Copy. When the updated version of ACS is installed, the previous version is renamed. You can copy the projects and libraries from the previous version using the following steps. If you have ACS version 5.4, or a previous version, you must manually copy the projects and libraries by following the steps below. To copy and paste folders: 1. Find the C:\ACS_DDMMYYYY_HHMMSS\Projects\ folder. 2. Copy and paste to the present C:\ACS\Projects\ folder. 3. Find the C:\ACS_DDMMYYYY_HHMMSS\library\pyLibrary\PTMLib\ folder. 4. Copy and paste to the present C:\ACS\library\pyLibrary\PTMLib\ folder. 5. Find the C:\ACS_DDMMYYYY_HHMMSS\library\26library\ folder. 6. Copy and paste to the present C:\ACS\library\26library\ folder. 4 PA-1008 Rev. U November 2023 ACS Standard Edition Version 6.3 Release Notes ACS 6.3 is based on the Python 3.7 programming language. If you customized your projects in a previous version of ACS you may need to change the projects created in the previous version of ACS, which includes the Python language test module (PTM) script libraries. You can go to this site to review the Python changes for more detail: https://docs.python.org/3/whatsnew/3.7.html#portingto-python-37 INSTALL ACS AFTER INSTALLING NI-488.2 DRIVERS If you are installing ACS on a system that contains NI-488.2 drivers, the following dialog box is displayed, indicating the applications identified are needed for installation. Make sure you select Do not close applications and Next to install (see the following figure). Figure 4: ACS 6.3 prepare to install SUPPORTED MODELS AND TEST CONFIGURATIONS ACS software is used to characterize semiconductor devices with a variety of Keithley Instruments products in a variety of different test configurations. The ACS Fundamentals Reference Manual (part number ACS-914-01) and ACS Advanced Features Reference Manual (part number ACS-908-01) contain detailed information about the supported hardware and test configurations. Perform multi-group testing with the Series 2600B and 2400 Graphical Touchscreen Series (GTS) instruments using ACS software installed on a personal computer or laptop. Control hardware using ACS software installed on the Model 4200A-SCS Parameter Analyzer or Model 4200-SCS. PA-1008 Rev. U November 2023 5 ACS Standard Edition Version 6.3 Release Notes Perform combined group testing with a 4200A-SCS Parameter Analyzer or 4200-SCS and Series 2600B instruments using the combined test-execution engine in ACS software. Control other external GPIB, LAN, or USB instruments using ACS software installed on a personal computer or laptop. The following table summarizes the instruments supported in the ACS test libraries. Instrument type Supported models SMU Instruments 2600B Series: 2601B-PULSE (DC only), 2601B, 2602B, 2604B, 2611B, 2612B, 2614B, 2634B, 2635B, 2636B 2600A Series: 2601A, 2602A, 2611A, 2612A, 2635A, 2636A 2400 Graphical Series SMU (KI24XX TTI): 2450, 2460, 2460-NFP, 2460-NFP-RACK, 2460-RACK, 2461, 2461-SYS, 2470 2400 Standard Series SMU: 2401, 2410, 2420, 2430, 2440 2650 Series for High Power: 2651A, 2657A 4200A and the following modules: 4210-CVU, 4215-CVU 4225-PMU/4225-RPM, 4225-RPM-LR, 4200-SMU, 4201-SMU, 4210-SMU, 4211-SMU, 4200-PA, 4200A-CVIV Parameter Analyzers DMM6500, DMM7510, 2010 Series DMMs 707A/B, 708A/B, 3700A Ultra-sensitive Current 6220, 6221, 2182A Sources an Nanovoltmeter Switching and data acquisition systems DAQ6510, 707A/B, 708A/B, 3700A Pulse Generators 3400 Series The following probers are supported in ACS: Probers Manual Prober Micromanipulator 8860 Prober Suss MicroTec PA200/Cascade CM300 Prober Cascade 12000 Prober Cascade S300 Prober Electroglas EG2X Prober Electroglas EG4X Prober TEL P8/P12 Prober TEL 19S Prober Tokyo Semitsu TSK9(UF200/UF3000/APM60/70/80/90) Prober Wentworth Pegasus 300S Prober with SRQ check Micromanipulator P300A Prober Yang Sagi3 Prober with SRQ check Signatone CM500 Prober (WL250) TEL T78S/80S Prober MPI SENTIO Prober Semiprobe SPFA Prober MJC AP-80 (SP-80) prober Apollowave AP200/AP300 Prober Vector Semiconductor AX/VX Series prober HiSOL prober (Python code) 6 PA-1008 Rev. U November 2023 ACS Standard Edition Version 6.3 Release Notes The graphical interactive test module (ITM) supports 24xx Graphical Series SMU instruments and 26xx instruments at the same time. The 24xx instrument should be connected as the primary instrument, and the 26xx connected as the subordinate. You can control any Test Script Processor (TSPTM) instrument using a script test module (STM) script. You can control any instrument using the Python language test module (PTM) script, including instrumentation from other vendors. Existing ACS STM and PTM libraries support specific instruments based on the library definition. SUPPORTED COMMUNICATIONS INTERFACE GPIB LAN (Auto Scan and LAN) USB RS-232 If you are using a RS-232 connection, the instrument is not automatically added to the hardware configuration. Add instruments connected with RS-232 manually and change the hardware configuration file that is in the following directory on your computer to the following: C:\ACS\HardwareManagementTool\HWCFG_pref.ini. In this file you change the baud rate, parity, byte, and stopBit settings. Review the following figure for details. Figure 5: RS-232 connection PA-1008 Rev. U November 2023 7 ACS Standard Edition Version 6.3 Release Notes SOFTWARE LICENSE ACS allows you to create tests, manipulate settings, and view previous data without a license. However, you must have a license for ACS to control and retrieve data from a physical instrument. You can launch a one-time, 60-day trial for ACS after the initial installation. Once the license expires, you need to purchase a full license to use the software. Figure 6: ACS 6.3 license information LICENSE MANAGEMENT The ACS software license is managed using the Tektronix Asset Management System (TekAMS). To generate a license file: 1. You must submit your Host ID to TekAMS. For more information about TekAMS, see tek.com/products/product-license. 2. To find the host ID, open the License Manage dialog box from the ACS Help menu. Select License > Host ID, then Click to copy to copy the Host ID. 3. Select Install. Figure 7: ACS Host ID 6.3 license information 8 PA-1008 Rev. U November 2023 ACS Standard Edition Version 6.3 Release Notes ACS STANDARD VERSION 6.3 ENHANCEMENTS: Issue number: ACS-784, CAS-209266-Y5K4F1 Enhancement: Support for the Keysight E4980A added Issue number: ACS-716 Enhancement: Support added for TSP-Link connections to the DMM6500 and DMM7510. Issue number: ACS-677 Enhancement: Add Hardware Scan Tool support for: · 6221 through GPIB and ethernet · 6220 through GPIB · 2182 and 2182A through RS232 or Trigger Link cable to the 6220 or 6221 HARDWARE CONFIGURATION: Issue number: ACS-766, CAS-199477-J6M6T8 Enhancement: Slow response when switching between PTMs and ITMs. Issue number: ACS-762 Enhancement: Support added for saving data to the Microsoft® Excel® format .xlsx. Issue number: ACS-724 Enhancement: Shared-Stress App: Added example library and project to show how the application works. Issue number: ACS-694, ACS-721 Enhancement: Develop HiSOL python prober driver in ACS. Issue number: ACS-718 Enhancement: DMM7510 and DMM6500 support: added tsp library DMM_SMU_lib.tsp including function FIMV_Sweep and FIMV_Sample. Issue number: ACS-717 Enhancement: 2601B and DMM7510 support: Add LIV_Lib.tsp library into ACS. Issue number: ACS-713, ACS-712 Enhancement: Created test module template Power MOSFET (SiC) Reliability application for ACS, including VTH_SiC, HTRB, HTGB. Issue number: ACS-690, ACS-689 Enhancement: Added standard PTM KI622x_2182_Lib.py to support KI622x+2182(A) Delta and Differential mode. Issue number: ACS-681, ACS-680, ACS-679 Enhancement: Issue number: Shared-Stress App: Added python library Share_Stress_App.py and Shared_Stress_Demo.py. ACS-676 Enhancement: Add a PTM demo script to run UTM library remotely on 4200A through KXCI. Issue number: ACS-664, CAS-143278-Z7L7T3 Enhancement: Supported generalized Shared-Stress in ACS. Issue number: ACS-653, CAS-124875-V3W1G7 Enhancement: UpgradeTool.exe was added to help convert your ACS 6.0 files or later to the present version, including projects, libraries, and settings from previous versions. ACS MANUAL UPDATES: Issue number: ACS-790, ACS-783, ACS-733, ACS-729, ACS-728, ACS-725, ACS-719, ACS-711 Enhancement: ACS 2600 RTM User's Manual, ACS Programmer's Manual, ACS Advanced Features Manual, ACS Fundamentals Reference Manual, and ACS Quick Start Guide update. PA-1008 Rev. U November 2023 9 ACS Standard Edition Version 6.3 Release Notes RESOLVED ISSUES: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: ACS-787 The status of spool is also 0 when it times out. This issue has been corrected. ACS-763, CAS-198461-L5X8W7 ACS formula issue, when the VTCI formula returns #REF unable to save data to a .xls file. This issue has been corrected. ACS-758 ITM 2461 Pulse mode incorrectly reached compliance at current lower than the limiti setting. This issue has been corrected. ACS-755 Formula from the last device-level running file is copied to all ITMs. This issue has been corrected. ACS-754, CAS-191991-W5S8D8 ACS CSV subsite unit is wrong. This issue has been corrected. ACS-753, CAS-191970-C6C2F3 ACS graph problem Fixed Scale. This issue has been corrected. ACS-752, CAS-191977-V4N4T0 ACS graph problem Log Scale. This issue has been corrected. ACS-751, CAS-191987-Q2T8Q5 ACS graph scale format error (Scientific Linear) This issue has been corrected. ACS-750, CAS-191988-X7C2L0 ACS graph scale format error (Scientific LOG) This issue has been corrected. ACS-740 The 2450, DMM6500, and DAQ6510 report errors when starting ACS. This issue has been corrected. ACS-737, CAS-183556-J8P1L6 ACS crashes during an abort test in an ITM sweep. This issue has been corrected. ACS-732 Need to enable the High C mode in the ITM when connected to a Model 2657A. This issue has been corrected. ACS-706 sintgv() is missing in TSPLPT. This issue has been corrected. ACS-705 Enabled the Combine SMU button in the hardware management configuration demo mode. This issue has been corrected. ACS-704, CAS-168192-R6R9C0 Inaccurate C measurement value is only at 10 kHz with ACS. This issue has been corrected. 10 PA-1008 Rev. U November 2023 ACS Standard Edition Version 6.3 Release Notes Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Enhancement: Resolution: Issue number: Symptom: Resolution: ACS-703 Manual - Some graphics are blurry and hard to read. This issue has been corrected. ACS-701 In the manual, the instructions for the ACSLPT checkparam() command is difficult to understand. This issue has been corrected. ACS-699 Add a Message Dialog to disallow renaming the ACS pattern, subsites, and device name that start with a number. This issue has been corrected. ACS-698 Grammar mistake in the error report of ACSLPT and SPLPT matrix functions. This issue has been corrected. ACS-697 Manual - ACSLPT matrix connection functions mistakenly add content for conpin, conpth, and delcon commands. This issue has been corrected. ACS-696 Manual - ACSLPT matrix path connection functions and the SMU should not be connected through the path. This issue has been corrected. ACS-695 TSPLPT delcon command is not working correctly. This issue has been corrected. ACS-693, CAS-162206-X6Q0Q9 ACS corrected the prober name Apolo to Apollo. This issue has been corrected. ACS-692, ACS-684, CAS-162203-C3L1R7 ACSPostGData() should be changed to ACSPostGdata() in the ACS Programmer's manual. This issue has been corrected. ACS-688 ACS cannot scan the Matrix 707B with 7072B cards in the hardware management tool. This issue has been corrected. ACS-687, CAS-157136-K7R9R0 High Open Offset Capacitance issue on the PCT HVCV Test. This issue has been corrected. ACS-686 Added ACSLPT functions bsweepi, bsweepv, sweepX, rtfary, savgi, savgv, sintgi, sintgv, smeasi, smeasv, sweepi, sweepv, trigig, trigvg, trigil, and trigvl commands for the 4200-SMU, 4201-SMU, 4210-SMU, and 4211-SMU. This issue has been corrected. ACS-686 Added ACSLPT sweepX, bsweepX functions for the 4200A SMU. This issue has been corrected. PA-1008 Rev. U November 2023 11 ACS Standard Edition Version 6.3 Release Notes Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: Issue number: Symptom: Resolution: ACS-685 Y1 and Y2 min/max scale in the plot setting is automatically changed when running a test. This issue has been corrected. ACS-671 Manual - Missing instructions for the ACSLPT sweep functions. This issue has been corrected. ACS-668 Manual - ACSPostArrayDouble function description is missing the array length parameter. This issue has been corrected. ACS-659 Added matrix to the TSP LPT instructions in the manual. This issue has been corrected. ACS-658 Removed smeasz_sweepv() from ACS programmer's manual. This issue has been corrected. SOFTWARE COMPATIBILITY Issue number: Resolution: N/A When you start ACS on a 4200A-SCS that has Clarius software version 1.4 or later (with Windows 10 operating system), a warning message may appear indicating that KXCI did not start successfully. Select Cancel to dismiss the warning. Figure 8: KXCI did not start 12 PA-1008 Rev. U November 2023 ACS Standard Edition Version 6.3 Release Notes To manually configure the compatibility settings: 1. Right-click the ACS icon and select Properties. 2. Open the Compatibility tab. 3. Select Run this program as an administrator and select OK to save. Figure 9: ACS properties PA-1008 Rev. U November 2023 13 ACS Standard Edition Version 6.3 Release Notes USAGE NOTES Issue number: Resolution: N/A When you install a KUSB-488B GPIB driver, the following message displays. You must select the Keithley Command Compatible option. Select Next to continue the installation. Figure 10: ACS command compatible Issue number: ACS-691, CAS-162126-B3Y7Y6 Resolution: Microsoft® Windows® mapped network drive error. When installing ACS Basic on a personal computer, Microsoft policy settings can limit ACS Basic from accessing mapped network drives in its file windows. Modifying the registry fixes this issue. To modify the registry: 1. Run regedit. 2. Navigate to HKEY_LOCAL_MACHINE/SOFTWARE/Microsoft/Windows/CurrentVersion/Policies/ System. 3. If one does not exist, create a new DWORD (32-bit) entry named EnableLinkedConnections. 4. Set the value to 1. 5. Restart the computer. 14 PA-1008 Rev. U November 2023