Fanvil H601/H601W/i501/i501W Quick Installation Guide

V1.0

Precautions

  1. Do not reboot the device during the system boot up or firmware upgrade process. It may damage the firmware image and cause the device malfunction.
  2. Please use the power adapter provided with the device. Using other unqualified power adapters may damage the device.

Overview

The Fanvil H601/H601W/i501/i501W are high-cost-performance IP series products that support HD voice and are equipped with shortcut call keys, making them suitable for hotel, residential, and hallway applications. The H601/i501 supports PoE power supply, while the H601W/i501W features built-in single-band Wi-Fi 6, reducing deployment costs while providing a high-quality user experience.

Packaging list

The packaging list includes:

Device installation

Wall mounting:

  1. Drill two holes in the wall with a vertical distance of 100mm.
  2. Drive in screw anchors and screws, leaving approximately 5mm between the screw cap and the wall for easy installation of the phone base.
  3. Connect the Ethernet cord, handset cord, and power.
  4. Align the wall mounting holes on the base with the screws and slide down to complete the installation.

Connecting to the device:

Connect the power adapter, network, and handset to the corresponding ports:

Keys description

H601/H601W:

i501/i501W:

Note: Contact your service provider for additional settings or download the user manual and FAQ for more detailed information.

Network connection

The H601W/i501W devices are pre-configured to connect to a network named "WiFi-device-ssid" with the default password "i<0%aY8+". Upon successful connection, the power light will blink 5 times.

Method 1 (Using W611W):

  1. Enter [Advanced Settings] on the W611W and go to [Share Wi-Fi] to enable Wi-Fi sharing, setting the office network SSID and password. The W611W acts as an AP.
  2. Power on the H601W/i501W devices.
  3. After powering up, the W611W will push the office network SSID and password to the H601W/i501W, enabling them to connect to the office network. The power indicator will flash quickly 5 times upon successful Wi-Fi connection.

Method 2 (Without W611W):

  1. Create a Wi-Fi network with the SSID "WiFi-device-ssid" and password "i<0%aY8+".
  2. After powering on, the H601W/i501W device will automatically connect to this Wi-Fi.
  3. Upon successful connection, the power indicator will flash quickly 5 times. Wi-Fi information can be modified via automatic deployment to connect to the office network.

Wi-Fi module configuration file example:

<<VOIP CONFIG FILE>>Version: 2.0000000000
<NET CONFIG MODULE>
--WIFIList-- :
Item1 WIFI Name : Redmi K60
Item1 WIFI SSID : Redmi K60
Item1 Secure Mode : 1
Item1 WIFI Encryption : 1
Item1 WIFI User Name : 12345678
<<END OF FILE>>

Configuration

  1. Obtain IP Address: In standby mode, press and hold the "Front Desk Key" (H601/H601W) or "Management Office" (i501/i501W). The IP address will be announced.
  2. Login: Enter the IP address in a web browser. Ensure the computer and phone are on the same IP address range. The default username is "admin" and the default password is "admin".
  3. Configuration: Select network/account settings and fill in the relevant information.
  4. Save Configuration.

Programmable key

  1. Login to the webpage: Navigate to Function Key > Function Key, select the desired function key, fill in the "Name" and "Value," and submit the settings.
  2. H601/H601W: Features 2 configurable function keys (default functions: "Front Desk" and "Do Not Disturb").
  3. i501/i501W: Features 3 configurable function keys (default functions: "Management Office", "Do Not Disturb", and "Unlock Door").

Federal Communication Commission (FCC) — USA

This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation.

This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Warning: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC Radiation Exposure Statement: The equipment complies with FCC Radiation exposure limits set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US: XXXXXXXXXXX. If requested, this number must be provided to the telephone company.

Models: H601, H601W, i501, i501W, H601 i501 Hotel IP Phone, H601 i501, Hotel IP Phone, IP Phone, Phone

PDF preview unavailable. Download the PDF instead.

11002r06v8 Adobe Illustrator 25.0 (Windows) iLovePDF

Related Documents

Preview Fanvil H601/H601W/i501/i501W Quick Installation Guide
This guide provides instructions for installing and configuring the Fanvil H601, H601W, i501, and i501W IP series products, which are designed for hotel, residential, and hallway applications.
Preview Fanvil i501/i501W SIP Indoor Station Datasheet
Datasheet for the Fanvil i501/i501W SIP Indoor Station, detailing its features, specifications, and functional capabilities for secure and convenient communication and access control in homes, offices, and hotels.
Preview Fanvil i501/i501W SIP Indoor Station Datasheet
Datasheet for the Fanvil i501/i501W SIP Indoor Station, detailing its features, specifications, and functional capabilities for secure and convenient communication and access control in homes, offices, and hotels.
Preview Fanvil i501/i501W SIP Indoor Station - Features and Specifications
Detailed information on the Fanvil i501/i501W SIP Indoor Station, highlighting its features such as HD audio, Wi-Fi 6 support, and remote unlocking capabilities. Includes technical specifications and packaging details.
Preview Fanvil i501(W) User Manual
User manual for the Fanvil i501(W) indoor station, detailing its features, installation, configuration, and troubleshooting. Learn how to use the device for intercom, door unlocking, and managing calls.
Preview Estación Interior SIP Fanvil i501/i501W: Características y Especificaciones Técnicas
Descubra la estación interior SIP Fanvil i501/i501W, ideal para hogares, oficinas y hoteles. Ofrece comunicación de audio clara, control de acceso remoto y Wi-Fi 6 (en i501W). Conozca sus características técnicas y capacidades.
Preview Fanvil A12 Audio Intercom: Quick Installation Guide
A concise guide for the Fanvil A12 Audio Intercom, detailing package contents, interface descriptions, physical specifications, installation procedures for wall-mounted and flush-mounted options, IP address searching methods, and essential intercom configuration steps.
Preview Fanvil V60W Basic Level IP Phone - Features and Specifications
Explore the Fanvil V60W, a basic-level IP phone featuring a 2.4-inch color screen, HD voice, 6-way conferencing, Wi-Fi 6, and Bluetooth 5.4 for enhanced business communication.