KEYENCE Safety Interlocking Switch GS-M Instructions Manual

This manual explains the handling, operation, and precautions for the Safety Interlocking Switch GS-M. Read this manual carefully and thoroughly understand its contents to use the GS-M to the full extent of its capabilities. Ensure that the end user receives this manual. This manual is the original instruction manual.

Symbols

Safety Precautions

DANGER

Important

Precautions on Regulations and Standards

CE Marking

KEYENCE Corporation confirms that this product complies with the essential requirements of applicable EU Directive(s). Use a power supply that complies with SELV or PELV. The full text of the EU declaration of conformity is available at: http://www.keyence.com/ce. These specifications do not guarantee end-product compliance; the end-product manufacturer is responsible for compliance.

UL Certificate

The GS-M is a UL/c-UL certified product (UL File No.: E301717, Category: NRKH/NRKH7, Enclosure Type 1). Use a power supply with Class 2 output defined in NFPA70 (NEC). Connect the power supply, external input, and control output to a single Class 2 power supply.

North American Regulations

The GS-M complies with FCC Part15 Subpart B (Class A), FCC Part15 Subpart C, ICES-003 (Class A), and RSS-210. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received. FCC CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Chapter 1 Before Operation

1-1 Overview

The GS-M is a Type 4 Interlocking Device based on ISO14119. It supports both low-level coded and high-level coded actuators. By combining the GS-M with a movable safety guard and a safety-related control system, hazardous machine operations can be stopped if the guard opens during operation.

Part descriptions

Main unit: Includes indicator, M12 connector, magnet center.

Actuator: Includes magnet center, indicator.

DANGER: Do not use the lock function with a safety-related control system.

1-2 Product List

Main unit

Models include GS-M5 (PNP/NPN, Terminal/M12 connector, Holding force 500N/900N, suitable for sliding door), GS-M9, and GS-ML5.

Actuator

ModelMain unitCoding levelWeight
GS-MA5MGS-M5LowApprox. 160 g
GS-MA5UGS-M5HighApprox. 160 g
GS-MA9MGS-M9LowApprox. 250 g
GS-MA9UGS-M9HighApprox. 250 g
GS-MAL5MGS-ML5LowApprox. 130 g
GS-MAL5UGS-ML5HighApprox. 130 g

Chapter 2 Installation

2-1 Installation Conditions

CAUTION

Important

Alignment tolerance

Typical Installation: Align alignment marks and magnet centers (GS-M5/GS-M9) or detection centers and magnet centers (GS-ML5). Refer to Chapter 6 for dimensions.

Actuator teaching (high coded actuator): After power ON, the main unit memorizes the first detected actuator for 3 seconds or more. The indicator blinks green upon completion. Only memorized actuators can be detected after restarting.

Chapter 3 Wiring

3-1 Terminal and Pin Assignment

Terminal type (GS-M50): Pin assignment for +24V, Safety input 1, Safety input 2, Lock control input, 0V, OSSD1, OSSD2, AUX output. Use a cable gland tested according to IEC 60529 (IP65/67) and IEC 62444 for IP65/67 rating and cable anchoring. Maximum cable length: 31 m. Cable size: AWG 26 to 16.

Standard type (GS-M51/ GS-M91/ GS-ML51): Pin assignment for AUX output, +24V DC, Lock control input, Safety input 2, OSSD1, OSSD2, 0V, Safety input 1. Wire colors are specified for each pin.

Advanced function type (GS-M53/ GS-M93/ GS-ML53): Pin assignment for +24V DC, Safety input 1, 0V, OSSD1, AUX output1, Safety input 2, OSSD2, EDM selection input, AUX output 2, Lock control input, Reset/EDM input, OSSD operation switching input. Wire colors are specified for each pin.

3-2 Wiring Example

Wiring examples are provided for GS-M50N (NPN), GS-M50P (PNP), GS-M51P/91P/L51P (PNP) with and without cascading, and GS-M53P/93P/L53P (PNP) with OSSD operation set to Lock link.

DANGER

Chapter 4 Functions

Functions vary by main unit model (simple, standard, advanced).

FunctionTerminal typeStandardAdvanced function
OSSD operationLock link or Open/close linkLock link or Open/close linkLock link or Open/close link
Safety inputs1*11*12
Interlock function
EDM function
Lock function
Number of AUX1*11*12

*1 When OSSD operation is set to "Open/close link", AUX cannot be used.

4-1 OSSD

OSSDs are safety outputs for machine control systems. OSSD 1/2 are redundant safety outputs. The GS-M performs self-diagnosis on its control circuit. If the internal control circuit does not receive a feedback signal (OFF-signal) based on self-diagnosis, the GS-M enters an error state.

OSSD operation

4-2 Safety Input

This function controls OSSDs using input signals from sensors or emergency stop switches. Safety input 1 and 2 form a pair; if either goes OFF, OSSDs go OFF. Multiple GS-M units can be cascaded.

4-3 Interlock Function

Prevents OSSDs from automatically going ON from OFF, preventing unintended machine start-up or restart. Reset operation is required. Advanced function type offers Automatic (OSSDs switch ON when conditions met) and Manual (OSSDs remain OFF until reset) settings.

4-4 EDM Function

Monitors external devices (e.g., force guided relay, magnetic contactor) connected to OSSDs to detect failures, enabling start/stop control.

4-5 Lock Function

Uses electromagnetic power to keep the guard closed where the GS-M actuator is installed.

4-6 AUX Output

Informational output for checking GS-M operating status. Operation varies by main unit type. AUX outputs turn ON if an error occurs.

Chapter 5 Specifications

5-1 Specifications

ParameterValue
Operating distance (OFF→ON)0.1mm
Operating distance (ON-OFF)15mm
Response time (Unlock Lock)250ms
Response time (Unlock Lock)250ms
Acceptable operation frequency1.6Hz (IEC 60947-5-3)
Control output (OSSD output)Transistor outputs × 2, Max. load current 150 mA
AUX (Non-safety-related output)Transistor output, Max. load current 50mA
External inputApprox. 1.5mA × 2 (Other values vary by function)
Power supply24 V DC ±20% (Ripple P-P 10% or less, Class2)
Power consumptionGS-M5 and GS-ML5: 5W, GS-M9: 6W
Protection circuitReverse current protection, short-circuit protection and surge protection for each output
Enclosure ratingIP65/67 (IEC60529)
Operating ambient temperature-20~55°C
Storage temperature-25~70°C
Operating relative humidity5%~95%RH
Storage relative humidity5%~95%RH
Vibration resistance10 to 55 Hz, Double amplitude 2.0 mm (IEC 60947-5-3)
Shock resistance30 G (IEC 60947-5-3)
Applicable Standards (Safety)EN61508, IEC61508(SIL3), EN ISO13849-1:2015 (PL e, Category 4), EN ISO14119(Type4), IEC60947-5-3, EN60947-5-3, UL 60947-5-2
MaterialMain unit: PBT, PET/PAR, TPC, PC, Nickel-plated steel. Actuator: Varies by model.
WeightGS-M50: Approx. 270 g, GS-M51/53: Approx. 250 g, GS-ML5: Approx. 240 g, GS-M9: Approx. 480 g

*1 Due to the flexible structure of the actuator, the guard can open 3.8 mm larger than the "Sar".

*2 Risk time according to IEC60947-5-3 is 150 ms + 2 ms x (number of cascaded units - 1).

*3 When stored for a long period of time, please store it at temperature of 55°C or lower.

Chapter 6 Appendix

6-1 Dimensions

Dimensional drawings are provided for GS-M5 (Main unit Terminal and M12 Connector, Actuator), GS-M9 (Main unit, Actuator), and GS-ML5 (Main unit, Actuator).

6-2 Indicator Descriptions

Descriptions of indicator lights for Lock link mode (OSSD Operation) and Lock control input are provided, including states like Green ON, Red OFF, Blinking green, etc.

6-3 Inspection and Maintenance

DANGER

Initial inspection: Verify correct installation, wiring, and operation of safety functions.

Periodic inspection: Inspect safety functions monthly or yearly based on SIL/PL ratings and usage frequency, following ISO 14119. Store inspection results. Errors cannot be repaired by the customer; replace the product or contact KEYENCE.

6-4 Cleaning

Clean the product if metal powder or similar substances are in contact with the faces of the main unit and actuator.

WARRANTIES AND DISCLAIMERS

KEYENCE warrants Products to be free of defects in materials and workmanship for one (1) year from shipment. This warranty does not apply to defects resulting from improper installation, interfacing, repair, modification, misapplication, or mishandling. KEYENCE will refund, repair, or replace defective Products at its sole option. Suggestions on product use are only suggestions; Buyer is responsible for ascertaining fitness for intended use. KEYENCE is not responsible for damages resulting from product use. Products are not to be used internally in humans, for human transportation, as safety devices, or fail-safe systems unless specified otherwise. Buyer will indemnify KEYENCE for any liability or damage arising out of misuse. ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. KEYENCE and its affiliates are not liable for any direct, indirect, incidental, punitive, special, or consequential damages arising from the use or inability to use the Products.

BUYER'S TRANSFER OBLIGATIONS: If Products are resold or delivered to a third party, Buyer must provide such third party with a copy of this document and all related specifications and information.

Document Control No. 1682AAE101-00

KEYENCE CORPORATION

1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan

PHONE: +81-6-6379-2211

www.keyence.com/glb

Copyright © 2021 KEYENCE CORPORATION. All rights reserved.

Models: 1682A, RF41682A, GS-M Series GS-M51P Safety Interlocking Switch, GS-M Series, GS-M51P, Safety Interlocking Switch

File Info : application/pdf, 4 Pages, 1.34MB

PDF preview unavailable. Download the PDF instead.

1682A-Users-Manual-Keyence-rf41682a-ex-1-9

References

Microsoft Word for Microsoft 365 Microsoft Word for Microsoft 365

Related Documents

Preview Keyence BT-A500 Series Handheld Terminal Instruction Manual
This document provides comprehensive safety precautions, operational guidelines, and specifications for the Keyence BT-A500 Series handheld terminal. It covers laser and LED safety, regulatory compliance, handling instructions, and detailed technical specifications.
Preview Keyence BT-A600 Series Handheld Terminal: Instruction Manual & Safety Guide
This document provides comprehensive instructions for the Keyence BT-A600 Series handheld terminal, covering safety precautions, handling, specifications, and regulatory compliance for models BT-A600, BT-A600MGA, and BT-A600MGE.
Preview Keyence DX Series Handheld Terminal Instruction Manual
This instruction manual provides essential safety precautions, operational guidelines, and technical specifications for the Keyence DX Series Handheld Terminal, including models DX-A600, DX-A600GE, DX-A400, DX-A400GE, and DX-W600. It covers topics such as LED and laser safety, regulatory compliance (FCC, CE, UKCA, ISED), installation of microSD and SIM cards, handling, cleaning, and specifications.
Preview KEYENCE WM-WL WLAN Unit Instruction Manual
Instruction manual for the KEYENCE WM-WL WLAN unit, covering safety precautions, regulatory information, and warranty details.
Preview Keyence PZ-V/M Series: Intelligent Reflective Photoelectric Sensors for Enhanced Stability
Discover the Keyence PZ-V/M Series of self-contained photoelectric sensors, offering superior stability and reliability in detecting various targets, including those with challenging colors, shapes, or backgrounds. Learn about their advanced technologies like P.S.D. and A.P.R. circuits, one-touch calibration, and robust design for harsh environments.
Preview KEYENCE DX Series Handheld Terminal Instruction Manual - Safety, Specifications, and Usage Guide
Comprehensive instruction manual for KEYENCE DX Series handheld terminals (DX-A600, DX-A600GE, DX-A400, DX-A400GE, DX-W600 models). Covers safety precautions, regulatory compliance (FCC, ISED, CE, UKCA, UL), unit installation, cleaning, specifications, and warranty information.
Preview Keyence DX Series Handheld Terminal Instruction Manual
This instruction manual provides detailed information on the Keyence DX Series handheld terminal, covering safety precautions, installation, handling, cleaning, and specifications. It is designed for users of the DX-A600, DX-A600GE, DX-A400, DX-A400GE, and DX-W600 models.
Preview KEYENCE PS-N10 Series Digital Photoelectric Sensor User's Manual
This user's manual provides comprehensive guidance on the operation, installation, and features of the KEYENCE PS-N10 Series Digital Photoelectric Sensor, ensuring safe and efficient use.