
Owner's Manual for Qlight models including: S60ADB Signal Warning Lights With High Volume Built In Buzzer, S60ADB, Signal Warning Lights With High Volume Built In Buzzer, Lights With High Volume Built In Buzzer, High Volume Built In Buzzer, Built In Buzzer, In Buzzer
4 2-Ø6 HOLES 4. 5 70 Min. Ø5 CABLE ENTRY Bulb Replacement Instructions(S60ADB)/ Mounting Hole Specifications S60ADL/ S60ADS/ A60ADB • Machine holes on the mounting surface referring to
S60ADL Falra SzerelhetÅ Fény és HangjelzÅ - Piros - 24VDC, S60ADL Elektronikus hangjelzÅ LED FényjelzÅ, S60ADL-24-R
File Info : application/pdf, 8 Pages, 2.09MB
DocumentDocumentSignal Light with High Volume Built-in Buzzer S60ADB/ S60ADL/ S60ADS 30 50 54 95dB Thank you for purchasing Qlight's products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use. Precautions for Safety Failure to follow the instructions below may cause a loss of life or serious physical injury. 1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.) 2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, malfunction or damage to the product.) 3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to follow this may cause damage to property, fire, electric shock and loss of life.) Precautions for Correct Use Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product that would void the warranty. 1. Please remove any objects that can interrupt ventilation around the product. 2. Please turn off the power of the product immediately if it fails to operate properly. 3. Carefully wire the product according to each product's specification. 4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product. 5. Do not apply excessive force/impact to the product. 6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock. Ordering Specifications S60ADL - [Model number] | · S60ADL · S60ADS · S60ADB 220 - [Voltage] | · 12-DC12V · 24-DC24V · 110-AC110V · 220-AC220V R [Color] | R-Red A-Amber G-Green B-Blue Please scan the QR code for more detailed product information. www.qlight.com 1 Product Specifications LED Steady/Flashing Signal Light Model number Voltage DC12V DC24V S60ADL AC110V AC220V Current 165mA 125mA 55mA 35mA Certificate Weight 0.17kg 0.17kg 0.32kg 0.32kg Color R - Red A - Amber G - Green B - Blue Xenon Lamp Strobe Signal Light Model number Voltage DC12V DC24V S60ADS AC110V AC220V Current 550mA 285mA 85mA 75mA Certificate Weight 0.29kg 0.29kg 0.27kg 0.27kg Color R - Red A - Amber G - Green B - Blue Bulb Steady/Flashing Signal Light Model number Voltage Current Bulb specifications Volts/ Watts Configuration Part# Certificate Weight Color DC12V 1A 12V10W 9 S60ADB DC24V AC110V 555mA 160mA 24V10W 110V10W T16x35 15S 10 12 AC220V 115mA 220V10W 13 0.19kg R - Red 0.19kg A - Amber 0.18kg G - Green B - Blue 0.18kg · Buzzer sound volume : Max.95dB at 1m · Protection rating : IP54 · Ambient operating temperature : -30°C to +50°C Dimensions S60ADL/ S60ADS/ S60ADB Ø70 48 (Units : mm) 71 233 10X10 CABLE ENTRY 2-Ø5.5 HOLES 44 15 28 60 23 35 Wiring Instructions S60ADB-DC/AC External Contact Red Gray Black Light Common(Steady) Common(Flash) White or Red Black Fuse Power 35 27 86 S60ADL/ S60ADS-DC/AC External Contact Red Brown Light Buzzer Black Fuse Power · S60ADB : External power line - UL1015 AWG18(0.75sq) x 2C 400mm External signal line - UL1007 AWG22(0.3sq) 400mm · S60ADL/ S60ADS : External power line - UL1007 AWG22(0.3sq) 400mm · This product can be wired regardless of polarity. 2 Parts Definition/ Installation/ Light Function Selection Parts Definition/ Installation S60ADS S60ADB Lens(AS) S60ADL Xenon lamp (Built-in type) Bulb LED unit Bolt Light function selection switch() · First, machine taps or holes on the mounting surface. · The mounting hole of this product bracket is 6mm in diameter. · When machining taps, fasten the bolt through the mounting hole of the bracket. · When machining holes, insert the bolt through the hole of the bracket, and tighten the nut from the opposite side of the mounting surface. Light Function Selection(S60ADL only) · Please refer to the chart below to use light function selection switch() located inside the product. L : Steady LF : Flashing · Default function is set at steady LED. Select the desired function for your application during installation. 3 Bulb Replacement Instructions(S60ADB)/ Mounting Hole Specifications Bulb Replacement Instructions Assemble bulb Mounting Hole Specifications · Machine holes on the mounting surface referring to the diagram below. Disassemble bulb 70 Min. Ø5 CABLE ENTRY 2-Ø6 HOLES 4.5 · Please wait at least 1 minute after turning off the power before replacing the bulb. · In order to dissemble the bulb, please push down the bulb() lightly and screw it counterclockwise. · In order to put the bulb in to the unit, please place the bulb() in the socket() and screw it clockwise while lightly pushing down the bulb. S60ADL/ S60ADS/ A60ADB Installation Environment and Protection Rating · This product is designed for use with protection rating of IP54. · If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating indicated(IP54), it may cause malfunction or damage to the product. · In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside- down positions where water can potentially penetrate into the product and impact it's operation. · For further information, please visit our website (www.qlight.com). 4 Product installation direction Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product. BEACON/SIGNALING LIGHT Power cord inlet part shall not be facing the sky. For products with a protection rating of less than IPX4, please install it vertically. ELECTRONIC SOUNDER/SIGNAL HORN Sounder part shall not be facing the sky. HEAVY-DUTY & EXPLOSION PROOF SIGNALINGS Sounder part shall not be facing the sky. SIGNAL TOWER LIGHTS Power cord inlet part shall not be facing the sky. For products with a protection rating of less than IPX4, please install it vertically. MEMO MEMO For your safety Specification and dimensions listed in this catalogue subject to change without notice for product quality improvement. The newest product information is available on our website.(www.qlight.com) Please read the instruction manual attached to the product carefully before installation and use. Qlight Co., Ltd. www.qlight.com | trade@qlight.com Head Office | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154 Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111) Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100 Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017 SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com China Factory/ Shanghai Sales Office | #Room 333 Building B, #11, Lane 450, Zhenda Road, Baoshan District, Shanghai, China Tel. +86 - 21 - 6651 - 7100 Fax. +86 - 21 - 6315 - 3929 China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China Tel +86- 513- 8384- 9999 Fax +86- 513- 8384- 9910 Product Operation Inquiry / Customer Support +82-51-620-4100 You can expect prompt service if you have exact information such as model name, symptom, telephone number and address. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507) Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805) www.qlight.com EN - S60ADL - 2405A