Owner's Manual for Qlight models including: S60ADB Signal Warning Lights With High Volume Built In Buzzer, S60ADB, Signal Warning Lights With High Volume Built In Buzzer, Lights With High Volume Built In Buzzer, High Volume Built In Buzzer, Built In Buzzer, In Buzzer

Signal Light with High Volume Built-in Buzzer S60ADB/ S60ADL/ S60ADS

4 2-Ø6 HOLES 4. 5 70 Min. Ø5 CABLE ENTRY Bulb Replacement Instructions(S60ADB)/ Mounting Hole Specifications S60ADL/ S60ADS/ A60ADB • Machine holes on the mounting surface referring to

S60ADL manual

S60ADL Falra Szerelhető Fény és Hangjelző - Piros - 24VDC, S60ADL Elektronikus hangjelző LED Fényjelző, S60ADL-24-R


File Info : application/pdf, 8 Pages, 2.09MB

260e3172331a64033feed611fc8b97e5 S60ADL manual
Signal Light with High Volume Built-in Buzzer
S60ADB/ S60ADL/ S60ADS

30 50
54

95dB

Thank you for purchasing Qlight's products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use.

Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.) 2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, malfunction or damage to the product.) 3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to follow this may cause damage to property, fire, electric shock and loss of life.)

Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product. 2. Please turn off the power of the product immediately if it fails to operate properly. 3. Carefully wire the product according to each product's specification. 4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product. 5. Do not apply excessive force/impact to the product. 6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.

Ordering Specifications

S60ADL

-

[Model number]
|
· S60ADL · S60ADS · S60ADB

220

-

[Voltage]
|
· 12-DC12V · 24-DC24V · 110-AC110V · 220-AC220V

R
[Color]
|
R-Red A-Amber G-Green B-Blue

Please scan the QR code for more detailed product information.
www.qlight.com
1

Product Specifications

LED Steady/Flashing Signal Light

Model number

Voltage

DC12V

DC24V S60ADL
AC110V

AC220V

Current
165mA 125mA 55mA 35mA

Certificate

Weight
0.17kg 0.17kg 0.32kg 0.32kg

Color
R - Red A - Amber G - Green B - Blue

Xenon Lamp Strobe Signal Light

Model number

Voltage

DC12V

DC24V S60ADS
AC110V

AC220V

Current
550mA 285mA 85mA 75mA

Certificate

Weight
0.29kg 0.29kg 0.27kg 0.27kg

Color
R - Red A - Amber G - Green B - Blue

Bulb Steady/Flashing Signal Light

Model number

Voltage

Current

Bulb specifications

Volts/ Watts

Configuration

Part#

Certificate

Weight

Color

DC12V 1A 12V10W

9

S60ADB

DC24V AC110V

555mA 160mA

24V10W 110V10W

T16x35 15S

10 12

AC220V 115mA 220V10W

13

0.19kg R - Red
0.19kg A - Amber
0.18kg G - Green B - Blue
0.18kg

· Buzzer sound volume : Max.95dB at 1m · Protection rating : IP54 · Ambient operating temperature : -30°C to +50°C

Dimensions

S60ADL/ S60ADS/ S60ADB

Ø70

48

(Units : mm)

71

233

10X10 CABLE ENTRY 2-Ø5.5 HOLES
44

15 28

60 23 35

Wiring Instructions

S60ADB-DC/AC

External Contact

Red Gray Black

Light Common(Steady) Common(Flash)

White or Red

Black

Fuse

Power

35 27 86

S60ADL/ S60ADS-DC/AC

External Contact

Red Brown

Light Buzzer

Black

Fuse

Power

· S60ADB : External power line - UL1015 AWG18(0.75sq) x 2C 400mm External signal line - UL1007 AWG22(0.3sq) 400mm
· S60ADL/ S60ADS : External power line - UL1007 AWG22(0.3sq) 400mm · This product can be wired regardless of polarity.

2

Parts Definition/ Installation/ Light Function Selection
 Parts Definition/ Installation

S60ADS

S60ADB

Lens(AS)

S60ADL

Xenon lamp (Built-in type)

Bulb LED unit
Bolt

Light function selection switch()

· First, machine taps or holes on the mounting surface. · The mounting hole of this product bracket is 6mm in diameter. · When machining taps, fasten the bolt through the mounting hole of the bracket. · When machining holes, insert the bolt through the hole of the bracket, and tighten the nut from the opposite side of the mounting
surface.
 Light Function Selection(S60ADL only) · Please refer to the chart below to use light function selection switch() located inside the product.

 L : Steady

 LF : Flashing

· Default function is set at steady LED. Select the desired function for your application during installation.

3

Bulb Replacement Instructions(S60ADB)/ Mounting Hole Specifications

 Bulb Replacement Instructions



Assemble

bulb



 Mounting Hole Specifications
· Machine holes on the mounting surface referring to the diagram below.

Disassemble bulb

70 Min. Ø5 CABLE ENTRY
2-Ø6 HOLES

4.5

· Please wait at least 1 minute after turning off the power before replacing the bulb.
· In order to dissemble the bulb, please push down the bulb() lightly and screw it counterclockwise.
· In order to put the bulb in to the unit, please place the bulb() in the socket() and screw it clockwise while lightly pushing down the bulb.

S60ADL/ S60ADS/ A60ADB

Installation Environment and Protection Rating
· This product is designed for use with protection rating of IP54. · If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP54), it may cause malfunction or damage to the product. · In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it's operation. · For further information, please visit our website (www.qlight.com).

4

Product installation direction

 Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product.

BEACON/SIGNALING LIGHT Power cord inlet part shall not be facing the sky.

 For products with a protection rating of less than IPX4, please install it vertically.

 ELECTRONIC SOUNDER/SIGNAL HORN Sounder part shall not be facing the sky.

HEAVY-DUTY & EXPLOSION PROOF SIGNALINGS Sounder part shall not be facing the sky.

SIGNAL TOWER LIGHTS Power cord inlet part shall not be facing the sky.

 For products with a protection rating of less than IPX4, please install it vertically.

MEMO

MEMO

For your safety

Specification and dimensions listed in this catalogue subject to change without notice for product quality improvement. The newest product information is available on our website.(www.qlight.com) Please read the instruction manual attached to the product carefully before installation and use.

Qlight Co., Ltd. www.qlight.com | trade@qlight.com Head Office | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154 Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111) Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100 Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com China Factory/ Shanghai Sales Office | #Room 333 Building B, #11, Lane 450, Zhenda Road, Baoshan District, Shanghai, China
Tel. +86 - 21 - 6651 - 7100 Fax. +86 - 21 - 6315 - 3929 China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86- 513- 8384- 9999 Fax +86- 513- 8384- 9910

Product Operation Inquiry / Customer Support +82-51-620-4100

You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.

ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE

RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507)

Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)

www.qlight.com

EN - S60ADL - 2405A



References

Adobe PDF Library 17.0 Adobe InDesign 19.0 (Windows)