Overview
The Shinko HR-700 Series is a hybrid recorder designed for industrial applications, offering a compact footprint, excellent visibility, and robust performance.
Key Features:
- Short depth (150mm) and lightweight (1.5kg) for installation in small control panels.
- Large 18mm high LED display for superior readability.
- Dustproof and drip-proof construction compliant with IEC60529 IP65 standards.
- Standard RS-232C communication, with optional RS-485 for FA system integration.
- CE marking compliant and UL/C-UL certified for safety and reliability.
Product Description
The HR-700 series hybrid recorder is designed for efficient data logging in demanding industrial environments. Its compact dimensions (144mm x 144mm x 150mm) make it suitable for space-constrained control panels. The large 18mm LED display ensures clear visibility of measurements and status information, even from a distance. The unit is built to withstand harsh conditions, featuring IP65 dustproof and drip-proof protection.
Visual Description of the Unit:
The Shinko HR-700 recorder is a compact, black-cased unit with a prominent front panel. It features a large, bright orange 8-segment LED display showing numerical data (e.g., "8:8.8.8.8.8"). Below the display are several operational buttons: REC, ALM, REC, ESC, MENU, PRINT, FEED, and ENT. The front panel also displays the model name "HR-700" and the brand "Shinko". CE and UL/C-UL certification marks are visible on the front.
Front Panel Layout and Operation
The front panel of the HR-700 series includes:
- ① Channel No. Display: An orange LED indicating the current channel number (1-6).
- ② Alarm Indicator Light: A red LED that illuminates to show the type of alarm (H for high limit, L for low limit).
- ③ Data Display: An orange LED display showing measured values, time, set points, and configuration parameters.
- ④ Status Indicator Lights: The 'REC' indicator (orange) lights up during recording operations, and the 'ALM' indicator (red) lights up when an alarm condition is active.
- ⑤ Operation/Setting Keys: Buttons used to navigate menus, access settings, and input data.
Specifications
Model Names and Input Points
Model: HR-70,□□ HR-700 (W144×H144 × D150mm)
Input Points | Description | Options |
---|---|---|
1 | 1 point (pen type) | |
2 | 2 points (pen type) | |
6 | 6 points (dot type) | |
- | C5: RS-485 Communication RE1: DI Function (pen type) RE6: DI Function (dot type) FL: Paper-out Detection LH3: Alarm Output (pen type) LH6: Alarm Output (dot type) |
Measurement Ranges and Accuracy
The following table details the supported input types, their measurement ranges, digital display resolution, and measurement accuracy.
Input Type | Range | Digital Display Resolution | Measurement Accuracy | Analog Recording Accuracy |
---|---|---|---|---|
Thermocouple K | -200.0~1370.0℃ | 0.1℃ | K1: ±(0.15% of rdg+0.7℃) | ±(0.3% of recording span) |
Thermocouple K | -200.0~600.0℃ | K2: ±(0.15% of rdg+0.4℃) | ||
Thermocouple K | -200.0~300.0℃ | K3: ±(0.15% of rdg+0.3℃) | ||
Thermocouple E | -200.0~800.0℃ | E1: ±(0.15% of rdg+0.5℃) | ||
Thermocouple E | -200.0~300.0℃ | E2: ±(0.15% of rdg+0.4℃) | ||
Thermocouple E | -200.0~150.0℃ | E3: ±(0.15% of rdg+0.3℃) | ||
Thermocouple J | -200.0~1100.0℃ | J1, T1: ±(0.15% of rdg+0.5℃) | ||
Thermocouple J | -200.0~400.0℃ | J2, T2: ±(0.15% of rdg+0.4℃) | ||
Thermocouple J | -200.0~200.0℃ | J3: ±(0.15% of rdg+0.3℃) | ||
Thermocouple T | -200.0~400.0℃ | T1, T2: ±(0.15% of rdg+0.5℃) | ||
Thermocouple R | 0.0~1760.0℃ | 0.1℃ | R1, S, B: ±(0.15% of rdg+1℃) | ±(0.3% of recording span) |
Thermocouple R | 0.0~1200.0℃ | R2: ±(0.15% of rdg+0.8℃) | ||
Thermocouple S | 0.0~1760.0℃ | S: ±(0.15% of rdg+1℃) | ||
Thermocouple B | 0.0~1820.0℃ | 0.1℃ | B: ±(0.15% of rdg+1℃) | ±(0.3% of recording span) |
Thermocouple B | 0.0~1820.0℃ | B: ±(0.15% of rdg+1℃) | ||
Thermocouple N | 0.0~1300.0℃ | 0.1℃ | ±(0.15% of rdg+0.7℃) | ±(0.3% of recording span) |
Thermocouple C | 0.0~2320.0℃ | 0.1℃ | ±(0.15% of rdg+1℃) | ±(0.3% of recording span) |
PR40-20 | 0~1880℃ | 0.1℃ | ±(0.15% of rdg+1℃) | ±(0.3% of recording span) |
Au-Fe | 0~1880℃ | 0.1℃ | ±(0.15% of rdg+1℃) | ±(0.3% of recording span) |
PL-II | -100~1390℃ | 0.1℃ | ±(0.15% of rdg+0.7℃) | ±(0.3% of recording span) |
U | -200.0~400.0℃ | 0.1℃ | ±(0.15% of rdg+0.5℃) | ±(0.3% of recording span) |
L | -200.0~900.0℃ | 0.1℃ | ±(0.15% of rdg+0.7℃) | ±(0.3% of recording span) |
Pt100 1 | -200.0~650.0℃ | 0.1℃ | ±(0.15% of rdg+0.3℃) | ±(0.3% of recording span) |
Pt100 2 | -200.0~200.0℃ | ±(0.15% of rdg+0.2℃) | ||
JPt100 1 | -200.0~630.0℃ | 0.1℃ | ±(0.15% of rdg+0.3℃) | ±(0.3% of recording span) |
JPt100 2 | -200.0~200.0℃ | ±(0.15% of rdg+0.2℃) | ||
DC Voltage | -10~10mV | 10 μV | ±(0.2% of rdg+3 digits) | ±(0.3% of recording span) |
DC Voltage | 0~20mV | 10 μV | ±(0.2% of rdg+3 digits) | |
DC Voltage | 0~50mV | 10 μV | ±(0.2% of rdg+2 digits) | |
DC Voltage | -200~200mV | 100 μV | ±(0.2% of rdg+3 digits) | |
DC Voltage | -1~1V | 1mV | ±(0.1% of rdg+3 digits) | |
DC Voltage | -10~10V | 10mV | ±(0.3% of rdg+3 digits) | ±(0.3% of recording span) |
DC Voltage | 0~5V | 1mV | ±(0.2% of rdg+2 digits) | ±(0.3% of recording span) |
DC Current | 4~20mA | 0.01mA | ±(0.2% of rdg+2 digits) | ±(0.3% of recording span) |
Note: DC current input requires an external shunt resistor (Model: RES-H725, sold separately).
Standard Specifications Summary
Item | Specification |
---|---|
Input Points | 1-pen (HR-701), 2-pen (HR-702), 6-dot (HR-706) |
Multi-range | Thermocouples, RTDs, DC Voltage, DC Current |
Input Resistance | Thermocouple/DC Voltage (mV): 10MΩ (no burnout), 200kΩ (burnout), DC Voltage (V): 1MΩ, DC Current (mA): 250Ω (with external resistor) |
Display | 6-digit, 7-segment orange LED display. Displays channel number, measured value, date, paper feed speed, alarm setpoints. |
Indicators | REC (orange) for recording, ALM (red) for alarms. |
Digital Accuracy | ±0.2% ±1 digit (for mV, V ranges); Thermocouple/RTD accuracy specified individually. |
Analog Recording Accuracy | ±(0.3% of recording span) |
Noise Rejection | Normal mode: 60dB or more (50/60Hz ±0.1Hz), Common mode: 140dB or more (50/60Hz ±0.1Hz) |
Withstand Voltage | 200V AC (input to input), 500V AC (input to ground), 1.5kV AC (power to ground) |
Environment | Ambient Temperature: 0~50℃, Ambient Humidity: 20~80% RH |
Safety Standards | UL: Input rating 100~240V AC, File No. E195801 |
Material | Flame-retardant resin (black case, transparent door) |
Durability | Dustproof and drip-proof (IEC60529 IP65 compliant) |
Mounting | Flush mounting in control panels (vertical panel). Max tilt angle: 0-30° backward. |
Weight | HR-701: approx. 2kg, HR-702: approx. 2.5kg, HR-706: approx. 1.5kg |
Included Functions | Dot skip, servo stop, self-diagnosis, zone recording, partial compression zoom, decade recording display, tag number setting, copy function, input offset setting, calculation, inter-channel calculation, scaling, burnout, memory backup, asynchronous printing mode, printer gap correction. |
Accessories | Recording paper, ink ribbon/cartridge, pens, packing, mounting brackets, user manual. |
Optional Functions
- Communication Function [C5]: RS-485 interface, Original or MODBUS RTU protocol, selectable speeds up to 38400 bps.
- DI Function [RE1]/[RE6]: Allows external control signals for functions like recording start/stop, paper speed switching, comment printing, external log printing, and external date printing.
- Paper-out Detection [FL]: Detects paper-out and stops recording, with an alarm output.
- Alarm Output Function [LH3]/[LH6]: Provides alarm outputs (up to 3 points for pen type, 6 points for dot type). Contact rating: 250V AC/3A, 30V DC/3A, 125V DC/0.5A (resistive load).
Terminal Arrangements and Dimensions
Terminal Arrangements:
- ① Alarm Output Terminals: For optional alarm outputs (e.g., Alarm 1, Alarm 2, etc.).
- ② Input Terminals: Connections for various input signals (Channel 1 to Channel 6).
- ③ Power Supply Terminals: For 100-240V AC power input.
- ④ RS-485 Communication Terminals (Optional): For RS-485 communication interface.
- ⑤ DI Function Terminals (Optional): For external digital inputs.
- ⑥ RS-232C Communication Terminals: For standard RS-232C communication interface.
External Dimensions:
The unit has a width and height of 144mm and a depth of 150mm. Diagrams show these dimensions clearly.
Panel Cutout Dimensions:
The recommended panel cutout size is 200mm x 138mm.
Mounting Angle: The unit can be mounted with a backward tilt angle of 0-30°.
Company Information
Shinko Technos Co., Ltd.
Head Office: 2-5-1 Funaba Higashi, Minoh City, Osaka 562-0035, Japan
TEL: (072)727-4571 FAX: (072)727-2993
URL: https://shinko-technos.co.jp/
E-mail: sales@shinko-technos.co.jp
Other offices are listed in the original document.
Important Notes
Safety Precautions: Please read the user manual carefully before use. This product is intended for industrial machinery, machine tools, and measuring instruments. Do not use for medical equipment or applications where human life is at risk. Implement appropriate protective devices and regular maintenance to prevent accidents due to product failure or malfunction. Do not use under conditions or environments not specified in the manual.
Export Control: Ensure the product is not used for weapons of mass destruction (military applications or facilities). Investigate the end-use and end-customer, and prevent unauthorized export.
Content is based on information available as of May 2022. Specifications are subject to change for product improvement. Photos may not represent actual usage conditions. For orders or inquiries, please contact your nearest sales office or dealer.