User Manual for SYPER BRIGHT LEDS models including: 70W LED, Flood Light, Yoke Mount, LED Light

Download AFLD User Manual

70W LED Flood Light with Yoke Mount - 9,100 Lumens - 250W Metal Halide Equivalent - 5000K | Super Bright LEDs

User Manual


File Info : application/pdf, 2 Pages, 2.00MB

PDF preview unavailable. Download the PDF instead.

AFLD User Manual
Important: Read all instructions prior to installation.
LED Flood Light
Safety and Notes
· Product should be installed and serviced in accordance with applicable national, state, and local building and electrical codes.
· To reduce the risk of electric shock, ensure that the main power source and circuit breakers are switched off before performing any installation or wiring procedures.
· Avoid looking directly into lamp when illuminated. · Ensure all mounts are securely attached and will support the weight of the
fixture. Failure to properly support fixture may result in damage or injury, for which the manufacturer does not assume responsibility.

User Manual
AFLD Series
AFLD-50K30-110-U

Specifications

Specifications Operating Temperature Environmental Rating

AFLD-50K15-110-x

Check product label for specific electrical specifications related to installation. Improper installation will void warranty.

AFLD-50K30-110-x

AFLD-50K50-110-x -40°­113° F (-40°­45° C)
IP65

AFLD-50K70-110-x

AFLD-50K90-110-x

Wiring Diagram

Line Neutral Ground

120­277 VAC Input

L

L

N

N

GND GND

Black White Green

Dim (+) Dim (-)

1­10 V Dimming

+

+

-

-

Purple Gray/Pink

Installation Instructions (U-bracket/Yoke Mount)
1. Drill holes for mounting and wiring. 2. Loosen light head adjustment screws with hex key. 3. Securely attach light to wall and connect wiring. 4. Rotate light head to desired angle and tighten adjustment screws.

Wall Drill

hex-key

Rev Date: V1 02/14/2022 4400 Earth City Expy, St. Louis, MO 63045

866-590-3533

superbrightleds.com

Important: Read all instructions prior to installation.
LED Flood Light
Installation Instructions (Knuckle Mount)

water-proof gasket cover of junction-box
screw

lamp wires

knuckle mount

User Manual
AFLD Series
1. Open junction box and run wiring into box.
2. Securely mount light to junction box. Use sealant to create weatherproof seal.
3. Connect wiring. 4. Replace junction box cover. 5. Rotate light head to desired
angle and tighten adjustment screws.

L

Black

N

White

Green

DC(+) Purple(DIM+)
DC(-) Pink(DIM-)
1-10VDimming

Installation Instructions (Slip-fitter)

hex-key
Only available on 70 W and 90 W lights. 1. Loosen light head adjustment screw with hex key. 2. Connect wiring. 3. Securely attach light to pole/post. The maximum pole/
post diameter is 2.375 in. 4. Rotate light head to desired angle and tighten
adjustment screw.

L N
DC (+) DC (-) 1-10V Dimming

Black White Green
Purple(DIM+) Pink(DIM-)

Rev Date: V1 02/14/2022 4400 Earth City Expy, St. Louis, MO 63045

866-590-3533

superbrightleds.com



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.2 (Windows)