User Manual for CAS models including: CAS IE-1700 Digital Crane Scale, CAS IE-1700, Digital Crane Scale, Crane Scale, Scale
CAS IE-1700 Digital Crane Scale - CAS Scales Australia
4 SAFETY GUIDE Read carefully the following instructio n and advice before using this scale. Over-loading this scale is harshly prohibited Refrain from long-time loading that could lead to excessive fatigue on loadcell used inside the scale. Excessive fatigue that on loadcell would decrease the
File Info : application/pdf, 15 Pages, 289.56KB
DocumentDocumentCONTENTS SAFETY GUIDE................................................4 PRECAUTION...................................................4 PRODUCT CHARACTERISTICS................5 SPECIFICATION ..............................................5 MODEL ...............................................................6 SIZE AND NET WEIGHT...............................7 OPERATION......................................................8 ELECTRICAL PRINCIPLE DIAGRAM...10 DISPLAY MESSAGE .....................................11 TROUBLESHOOTING .................................12 REMOTE CONTROLLER...........................13 SAFETY GUIDE Read carefully the following instruction and advice before using this scale. ¥ Over-loading this scale is harshly prohibited ¥ Refrain from long-time loading that could lead to excessive fatigue on loadcell used inside the scale. Excessive fatigue that on loadcell would decrease the accuracy and shorten the life of scale. ¥ Check the shackle and hook regularly. ¥ Check the battery power level before/after use and recharge the scale in time. ¥ In order to maximize the battery life, periodic recharging is necessary for scales even not in use for long time. ¥ Do not try to repair the scale by yourselves. ¥ Use privately attached charger only. PRECAUTION ¥ The crane scale is a kind of precise weighing instrument, pay attention on operantion and maintenance. ¥ Rotate the load instead of machine otself if necessary for operation. ¥ Stop using the machine under the circumstances of thunder & rain. ¥ Check periodicly if the clips/pins and screws of the machine are loose or broken before use. ¥ If low battery signal appeare & LED annunciator goes green while charging, please check the battery. ¥ Hang the machine instrad for storage while not in use in order to prevent from unnecessary load in the weight sensor inside. ¥ Do not subject the scale to sudden to sudden temperature changes. ¥ Avoid from the shock of excessive weight. PRODUCT CHARACTERISTICS Model Display characteristics IE Series 30mm(1.2)LED 30mm(1.2)LCD High accuracy, small volume, easy to bring ¥ High quality: The process management is operated according to OIML R76, GB/T11883-2002, and get the European CE certificate. ¥ Safty installation: Aluminum Die-Casting Case, high intensity hook and shackle, special loadcell for safty installation. ¥ High reliability: Using high quality components on PCB circul board to board to insure long time stability. ¥ Broad applicability: 30mm high character display, 25M distance eyeshot, can be used in storage industry, textile industry, metallurgy industry etc. ¥ Simple operation: Check battry voltage automatically, wireless remote controller, separate battery space, small volume, easy to bring. ¥ Complete function: Kg/Lb conversion, Hold, Tare, Division choice, Stablity regulation, Accumulation/Search, Gross/Net conversion, parameter regulation etc. SPECIFICATION Standard GB/T11883-2002zElectrical Crane Scale{ Accuracy class OIML class III Display 30mm(1.2) 5digits LCD/LED Zero Range 4% full capacity Tare Range 100% Full capacity Stable Time 10 seconds Overload Indication 100% Max. capacity + 9e Max. Safety Load 125% Max. capacity Ultimate Load 400% Max. capacity Battery Life 50 hours Battery Type Fully sealed Lead-Acid battery, 6V/5Ah Adapter DC9V/1500mA Operating Temp. - 10 ~ + 40 Operating Humidity 85% RH under 20 Remote Controller Distance Min. 10m Battery of Remote Controller 5# battery, 1.5V2 MODEL Model IE-100 Max. capacity (kg / lb) 50/100 Min. capacity (kg / lb) 0.5/1 Division (kg / lb) 0.02/0.05 IE-200 100/200 1/2 0.05/0.1 IE-500 200/500 2/4 0.1/0.2 IE-1000 500/1000 4/10 0.2/0.5 IE-2000 1000/2000 10/20 0.5/1 Total display (kg / lb) n=2000 n=2000 n=2500 n=2000 n=2000 SIZE AND NET WEIGHT Max.Capacity 100kg 200kg 300kg 500kg 1000kg L (mm) 335 335 335 360 360 A (mm) 20 20 20 25 25 B (mm) 65 65 65 75 75 C (mm) 20 20 20 20 20 Net weight 4.0 4.0 4.0 4.2 4.2 Notice: If there's any modification, all the date are subject to the scale itself. OPERATION ¥ TURN ON Operation OFF/ON Display 8.8.8.8.8 500.0 U X.XX ----- 0 Illustration Display two times Display capacity two times Display the voltage of battery Wait stable signal "STB" light, can hang the weight Notice: To guarantee the accuracy, leave scale alone for 3~5 minutes after turning on. ¥ ZERO Operation Press0on scale Press ZERO on controller Display 0 0 Illustration After turn on, generally display 0, if not for 0 Can operate like this ¥ TARE Operation Display Illustration PressTon scale Press TARE on controller 0 Press this key to deduct the weight of Container, while "TARE" light on, the 0 Scale will show the net weight of load Notice: As crane scale deduct the weight of container automatically, so it will show the net weight of load every time, you needn't press this key to get net weight until you change the container or turn off. OVERLOAD WARNING The display will show-OL-once the load (Net + Tare) exceeds Max. capacity. Make sure that the load are within the capacity range, otherwise it's very dangerous. ¥ CHECK BATTERY PressOFF/ONon scale, when turn on or turn off, it showsU X.XX Press OFFon controller 2 seconds Stable after 15 minute, it show , after 60minutes, it turn off automaticaly. ¥ HOLD THE WEIGHT READING Press "HOLD" key on the remote controller to hold the displayed weight reading. At this moment, "HOLD" light on, Press this key again will disable hold function. ¥ LOW BATTERY WARNING When the battery voltage lower thenU 5.8.0, the display flash, but the scale can still work until the display show -Lb- , one minute later, it will turn off automatically, you need to recharge the battery to use again. ¥ POWER SAVING The display will show when the load are at stable status in excess of 15 minutes and revert to normal weighing readings while load changes. When the load are at stable status in excess of 60 minutes, the scale will turn off automatically ¥ RECHARGING BATTERY 1. Turn off, connect the adapter with 220V AC power supply, also insert the plug in the socket which located in the rear of scale. The light become green, it means it's recharging automatically, until the green light become red, that means recharging is finished. 2. When you need to use crane scale hour after hour, take off the rear cover, change the battery with recharged battery. Attention : Generally, the time of recharging should not lower than 8 hours, this scale have recharging protection function, long time recharging will not damage the battery. ¥ TURN OFF PressOFF/ONon scale 2 seconds PressOFFon controller 2 seconds Stable after 15minutes, it show , after 60minutes, it turn off automatically. ELECTRICAL PRINCIPLE DIAGRAM Load cell Signal enlarges Control key Control distance A/D CPU LED or LCD display Battery DISPLAY MESSAGE Display Illustration - - - - - Waiting stable Err10 Accumulated weight not exceed Min. Capacity Err11 Accumulated times exceed, (can't accumulate after 30times) Err12 Accumulated weight exceed (can't accumulate after 99999) CLr Ask if you really want to delete accumulated weight, in case error deletion noCLr Give up deletion 88888 Confirm deletion noACC No any accumulated value (when you check) SHIFt Conversion, when you press SHIFT in controller UX.XX The voltage of current battery SCALE Enter weight adjustment SEtUP Enter parameter adjustment UAdJ Enter voltage adjustment -OL- Overload warning -Lb- Low battery warning End End, when parameter adjustment ready OFF Turn off TROUBLESHOOTING Phenomenon Reason No display when Turn on Battery damaged Battery contact loosed Display flash Low battery Min.Capacity Can't trun on & off OFF/ONAbuttun damaged Can't tare TAREAbuttun damaged Recharge indicator Light can't turn on The recharger damaged The recharger isn't plugged ready The load is unstable Display isn't stable The display don't show "0" when empty load The error is large Loadcell cable damaged The scale in damp Environment for a long time No enough time for heating the scale after turn on Put the scale on ground for too long time The scale isn't hung properly Battery can't recharge Battery damaged Outlet damaged Remote distance Receiver window is too dirty shorten Low battery of controller Solution Check battery Tighten the contact Recharge the battery Check & clean the buttun Check & clean the buttun Check the recharger Insert plug again Stablize the load Check and replace loadcell Put the scale in dry Environment After turning on, heating 3-5 minutes. Scale should be hung Check the scale and sling Replace battery Replace the outlet Check and clean Replace controller battery REMOTE CONTROLLER GUIDE ¥ Lightness of display Operation Illustration F1 0~5, 0: no display, 1: Minimum light, 5: Maximum light (Default: 2) µ ZERO Operation Illustration ZERO display 0 when no load, "ZERO" light on µ HOLD Operation Illustration HOLD Hold the weight, "HOLD" light on HOLD Convert to weighing situation, "HOLD" light off µ TARE 1. Tare directly Operation Illustration TARE Display show net weight, "TARE" light on TARE Display show gross weight, "TARE" light off 2. Set tare weight in advance Operation MR TARE display SHIFT 00000 **** MR - *** Illustration Current tare weight Input the tare weight Exit, "TARE" light on, it will deduct tare weight automatically when weighing. µ ACCUMULATION Operation display Illustration . /P Current accumulation times ) Rear four digit of current accumulated value - Front four digit of current accumulated value Attention: After display two times circlely, it will return to weigh situation automatically, you also can press MR to return directly. µ SEARCH Operation display Illustration .3 /P Current accumulation times . Current weight ) Rear four digit of current accumulated value - Front four digit of current accumulated value .3 Return to weigh Attention: Press5"3&and ª«can search every time weight and accumulated value, press .3 return. µ CLEAR Operation $-&"3 $-&"3 display $-S OP$-S Illustration Display blink, please confirm if you want to delete Accumulated value Cancel deletion .3 Confirm deletion µ ZERO DISPLAY Operation .3 ª« display Illustration 4)*'5 Display current zero value µ KG/LB CONVERSION Operation display Illustration .3 4)*'5 Un = 0 : kg "lb" light off $-&"3 6O Un = 1 : kg "lb" light on, µ SEARCH OVERLOAD TIMES Operation .3 $-&"3 display 4)*'5 0- Illustration Display times of overload µ VOLTAGE DISPLAY Operation .3 ' .3 display Illustration 4)*'5 6999 Display show current voltage of the battery Return to weigh µ TURN OFF Operation 0'' display Illustration 0'' 6999 Display show current voltage of battery then turn offGPL Ghostscript 9.55.0