CONTENTS

SAFETY GUIDE................................................4 PRECAUTION...................................................4 PRODUCT CHARACTERISTICS................5 SPECIFICATION ..............................................5 MODEL ...............................................................6 SIZE AND NET WEIGHT...............................7 OPERATION......................................................8 ELECTRICAL PRINCIPLE DIAGRAM...10 DISPLAY MESSAGE .....................................11 TROUBLESHOOTING .................................12 REMOTE CONTROLLER...........................13




























SAFETY GUIDE
Read carefully the following instruction and advice before using this scale.
¥  Over-loading this scale is harshly prohibited ¥  Refrain from long-time loading that could lead to excessive fatigue on loadcell
used inside the scale. Excessive fatigue that on loadcell would decrease the accuracy and shorten the life of scale. ¥  Check the shackle and hook regularly. ¥  Check the battery power level before/after use and recharge the scale in time. ¥  In order to maximize the battery life, periodic recharging is necessary for scales even not in use for long time. ¥  Do not try to repair the scale by yourselves. ¥  Use privately attached charger only.
PRECAUTION
¥  The crane scale is a kind of precise weighing instrument, pay attention on operantion and maintenance.
¥ Rotate the load instead of machine otself if necessary for operation. ¥ Stop using the machine under the circumstances of thunder & rain. ¥ Check periodicly if the clips/pins and screws of the machine are loose or broken
before use. ¥  If low battery signal appeare & LED annunciator goes green while charging,
please check the battery. ¥  Hang the machine instrad for storage while not in use in order to prevent from
unnecessary load in the weight sensor inside. ¥  Do not subject the scale to sudden to sudden temperature changes. ¥  Avoid from the shock of excessive weight.





PRODUCT CHARACTERISTICS


Model

Display

characteristics

IE Series

30mm(1.2)LED 30mm(1.2)LCD

High accuracy, small volume, easy to bring



¥  High quality: The process management is operated according to OIML R76,

GB/T11883-2002, and get the European CE certificate.

¥  Safty installation: Aluminum Die-Casting Case, high intensity hook and shackle,

special loadcell for safty installation.

¥  High reliability: Using high quality components on PCB circul board to board to insure

long time stability.

¥  Broad applicability: 30mm high character display, 25M distance eyeshot, can be used

in storage industry, textile industry, metallurgy industry etc.

¥  Simple operation: Check battry voltage automatically, wireless remote controller,

separate battery space, small volume, easy to bring.

¥  Complete function: Kg/Lb conversion, Hold, Tare, Division choice, Stablity regulation,

Accumulation/Search, Gross/Net conversion, parameter regulation etc.



SPECIFICATION



Standard

GB/T11883-2002zElectrical Crane Scale{

Accuracy class

OIML class III

Display

30mm(1.2) 5digits LCD/LED

Zero Range

4% full capacity

Tare Range

100% Full capacity

Stable Time

10 seconds

Overload Indication

100% Max. capacity + 9e

Max. Safety Load

125% Max. capacity

Ultimate Load

400% Max. capacity

Battery Life

50 hours

Battery Type

Fully sealed Lead-Acid battery, 6V/5Ah

Adapter

DC9V/1500mA

Operating Temp.

- 10 ~ + 40





Operating Humidity

85% RH under 20

Remote Controller Distance Min. 10m

Battery of Remote Controller 5# battery, 1.5V2


MODEL

Model IE-100

Max. capacity (kg / lb)
50/100

Min. capacity (kg / lb)
0.5/1

Division (kg / lb)
0.02/0.05

IE-200

100/200

1/2

0.05/0.1

IE-500

200/500

2/4

0.1/0.2

IE-1000

500/1000

4/10

0.2/0.5

IE-2000

1000/2000

10/20

0.5/1

Total display (kg / lb) n=2000 n=2000 n=2500 n=2000 n=2000

 


SIZE AND NET WEIGHT

Max.Capacity
100kg 200kg 300kg 500kg 1000kg

L (mm) 335 335 335 360 360

A (mm)
20 20 20 25 25

B (mm)
65 65 65 75 75

C (mm)
20 20 20 20 20

Net weight
4.0 4.0 4.0 4.2 4.2

  Notice: If there's any modification, all the date are subject to the scale itself.





OPERATION

¥  TURN ON

Operation
OFF/ON

Display

 8.8.8.8.8 

 500.0 

 U X.XX 

 ----- 



0

Illustration
Display two times Display capacity two times Display the voltage of battery Wait stable signal "STB" light, can hang the weight

 Notice: To guarantee the accuracy, leave scale alone for 3~5 minutes after turning on.

¥  ZERO

Operation
Press0on scale Press  ZERO  on controller

Display



0



0

Illustration

After turn on, generally display



0, if not for 

0

Can operate like this

¥  TARE

Operation

Display

Illustration

PressTon scale 

Press  TARE  on controller



0 Press this key to deduct the weight of Container, while "TARE" light on, the
0 Scale will show the net weight of load

 Notice: As crane scale deduct the weight of container automatically, so it will show the net weight of load every time, you needn't press this key to get net weight until you change the container or turn off.

 OVERLOAD WARNING
The display will show-OL-once the load (Net + Tare) exceeds Max. capacity. Make sure that the load are within the capacity range, otherwise it's very dangerous.

 



¥  CHECK BATTERY

PressOFF/ONon scale, when turn on or turn off, it showsU X.XX

Press OFFon controller 2 seconds

Stable after 15 minute, it show

, after 60minutes, it turn off automaticaly.

¥  HOLD THE WEIGHT READING
Press "HOLD" key on the remote controller to hold the displayed weight reading. At this moment, "HOLD" light on, Press this key again will disable hold function.
¥  LOW BATTERY WARNING
When the battery voltage lower thenU 5.8.0, the display flash, but the scale can still work until the display show  -Lb- , one minute later, it will turn off automatically, you need to recharge the battery to use again.
¥  POWER SAVING
The display will show   when the load are at stable status in excess of 15 minutes and revert to normal weighing readings while load changes. When the load are at stable status in excess of 60 minutes, the scale will turn off automatically
¥  RECHARGING BATTERY
1. Turn off, connect the adapter with 220V AC power supply, also insert the plug in the socket which located in the rear of scale. The light become green, it means it's recharging automatically, until the green light become red, that means recharging is finished.
2. When you need to use crane scale hour after hour, take off the rear cover, change the battery with recharged battery.
Attention : Generally, the time of recharging should not lower than 8 hours, this scale have recharging protection function, long time recharging will not damage the battery.

¥  TURN OFF 

PressOFF/ONon scale 2 seconds PressOFFon controller 2 seconds Stable after 15minutes, it show , after 60minutes, it turn off automatically.





ELECTRICAL PRINCIPLE DIAGRAM 

Load cell

Signal enlarges

Control key

Control distance

A/D

CPU

LED or LCD display

Battery

 



DISPLAY MESSAGE

Display

Illustration

 - - - - - Waiting stable

 Err10 Accumulated weight not exceed Min. Capacity

 Err11 Accumulated times exceed, (can't accumulate after 30times)

 Err12 Accumulated weight exceed (can't accumulate after 99999)

 CLr Ask if you really want to delete accumulated weight, in case error deletion

 noCLr Give up deletion

 88888 Confirm deletion

 noACC No any accumulated value (when you check)

 SHIFt Conversion, when you press SHIFT in controller

 UX.XX The voltage of current battery

 SCALE Enter weight adjustment

 SEtUP Enter parameter adjustment

 UAdJ  Enter voltage adjustment

 -OL-  Overload warning

 -Lb-  Low battery warning

 End  End, when parameter adjustment ready

 OFF  Turn off





TROUBLESHOOTING

Phenomenon

Reason

No display when Turn on

Battery damaged Battery contact loosed

Display flash

Low battery Min.Capacity

Can't trun on & off

OFF/ONAbuttun damaged

Can't tare

TAREAbuttun damaged

Recharge indicator Light can't turn on

The recharger damaged
The recharger isn't plugged ready
The load is unstable

Display isn't stable
The display don't show "0" when empty load The error is large

Loadcell cable damaged
The scale in damp Environment for a long time No enough time for heating the scale after turn on Put the scale on ground for too long time
The scale isn't hung properly

Battery can't recharge

Battery damaged Outlet damaged

Remote distance

Receiver window is too dirty

shorten

Low battery of controller

Solution Check battery Tighten the contact Recharge the battery Check & clean the buttun Check & clean the buttun Check the recharger
Insert plug again
Stablize the load Check and replace loadcell Put the scale in dry Environment After turning on, heating 3-5 minutes. Scale should be hung
Check the scale and sling Replace battery Replace the outlet Check and clean Replace controller battery

 



REMOTE CONTROLLER GUIDE

¥ Lightness of display 

Operation

Illustration

F1 0~5, 0: no display, 1: Minimum light, 5: Maximum light (Default: 2)

µ ZERO

Operation

Illustration

ZERO display 0 when no load, "ZERO" light on

µ HOLD

Operation

Illustration

HOLD Hold the weight, "HOLD" light on

HOLD Convert to weighing situation, "HOLD" light off

µ  TARE
1. Tare directly

Operation

Illustration

TARE Display show net weight, "TARE" light on

TARE Display show gross weight, "TARE" light off

2. Set tare weight in advance

Operation  MR  TARE

display SHIFT 00000  ****

 MR 

 - ***

Illustration
Current tare weight Input the tare weight Exit, "TARE" light on, it will deduct tare weight automatically when weighing.





µ  ACCUMULATION

Operation

display

Illustration

 .  /P Current accumulation times

) Rear four digit of current accumulated value

- Front four digit of current accumulated value

Attention: After display two times circlely, it will return to weigh situation automatically, you also can press MR to return directly.

µ  SEARCH

Operation

display

Illustration

 .3  /P Current accumulation times

 .   Current weight



) Rear four digit of current accumulated value



- Front four digit of current accumulated value

 .3 

    Return to weigh

Attention: Press5"3&and ª«can search every time weight and accumulated value, press
 .3 return.

µ  CLEAR

Operation $-&"3 $-&"3

display  $-S  OP$-S

Illustration
Display blink, please confirm if you want to delete Accumulated value
Cancel deletion

 .3    Confirm deletion

µ  ZERO DISPLAY

Operation  .3  ª«

display

Illustration

4)*'5

   Display current zero value







µ  KG/LB CONVERSION

Operation display

Illustration

 .3  4)*'5 Un = 0 : kg "lb" light off

$-&"3 6O   Un = 1 : kg "lb" light on,

µ  SEARCH OVERLOAD TIMES

Operation  .3  $-&"3

display 4)*'5 0-

Illustration Display times of overload

µ  VOLTAGE DISPLAY

Operation  .3   '   .3 

display

Illustration

4)*'5

6999 Display show current voltage of the battery

     Return to weigh

µ  TURN OFF

Operation 0''



display

Illustration

 0''  6999

Display show current voltage of battery then turn off



 
 

