Instruction Manual for ALLEN HEATH models including: M-SQ-MADI-A, M-SQ-MADI-A Expansion Card, Expansion Card, Card

M-SQ-MADI fitting note

SQ MADI Fitting Instructions

Resources - Allen & Heath


File Info : application/pdf, 2 Pages, 100.31KB

PDF preview unavailable. Download the PDF instead.

M-SQ-MADI fitting note AP12392 iss2
SQ MADI Option Card

M-SQ-MADI-A is one of several audio networking options that can be fitted to an Allen & Heath SQ mixer. It provides 64x64ch of 48/96kHz AES MADI (AES10) over coaxial BNC.
 SQ MADI requires SQ Firmware V1.5.2 or later.
 To avoid damage to the BNC sockets, plug and unplug
any cable with care and make sure the cables are terminated with standard BNC connectors (IEC 60169-8).
Fitting the card
1. Switch the system off. 2. Use a Torx T8 driver to remove the 2 screws securing the I/O Port
blank panel to the SQ mixer. 3. Slide the card into the slot and press it firmly into the mating
connector. 4. Refit the 2 screws to secure the card.

Front panel

Link 1 BNC connectors for 75ohm coaxial cables up to 150m. It gives access to: Input 1-64, output 1-64 @48kHz Input 1-32, output 1-32 @96kHz

Link 2 Can be configured as a Link 1 redundant connection or as a second MADI port. With Redundancy off, it gives access to: Output 1-64 @48kHz. Input 33-64 and output 33-64 @96kHz.

Lnk/Err flashes yellow to indicate network activity. Illuminates red when a connection or data error is detected.
M-SQ-MADI-A Fitting Note

Word clock Configurable as Word clock input or output. The LED indicates current mode.
AP12392 Issue 1

Card setup and patching signals
Synchronising the SQ to a MADI clock source is a two-step process: 1. Select the clock source for the mixer in the Setup / Audio / Audio Sync screen. Typically, this is set to internal, but select I/O Port to sync to the fitted option card. 2. Select the clock source for the MADI card in the Setup / Audio / I/O Port screen. Either the wordclock input or a link input can be chosen.
Use the Setup / Audio / I/O Port screen to set the sample rate, sync source and redundancy mode for the MADI card. Use the SQ I/O screen to patch signals to or from the I/O Port.
 For more information on SQ setup and functions please
refer to the latest SQ Firmware Reference Guide available for download from www.allen-heath.com.
A limited one year manufacturer's warranty applies to this product, the conditions of which can be found at: www.allen-heath.com/legal.
This product complies with the European Electromagnetic Compatibility directive 2014/30/EU and the European Low Voltage directive 2014/35/EU.
Copyright © 2020 Allen & Heath. All rights reserved.