Owner's Manual for MEAN WELL models including: HDR-30-24 AC-DC Power Supply, HDR-30-24, AC-DC Power Supply, Power Supply, Supply
HDR-30-24 Mean Well From 477.4 UAH - РАДИОМАГ РКС КОМПОНЕНТЫ Manufacturer: Mean-Well USA, Inc. AC/DC Power Supply Single-OUT 24V 1.5A 36W 4-Pin
HDR-30-24 MeanWell вÑд 477.4 гÑн - Ð ÐÐÐÐÐÐÐ Ð ÐС ÐÐÐÐÐÐÐÐТЫ
File Info : application/pdf, 4 Pages, 206.54KB
DocumentDocument30W Ultra Slim Step Shape DIN Rail HDR-30 series User's Manual UL508 UL62368-1 Features Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN61558 R33100 RoHS TPTC004 AS/NZS60950-1 IEC62368-1 Ultra slim design with 35mm(2SU) width Universal input 85~264VAC(277VAC operational) No load power consumption<0.3W Isolation class Pass LPS (Limited power source) DC output voltage adjustable Protections : Short circuit / Overload / Over voltage Cooling by free air convection (working temperature:-30~+70°C) DIN rail TS-35/7.5 or 15 mountable LED indicator for power on 3 years warranty Applications Household control system Building automation Industrial control system Factory automation Electro-mechanical apparatus GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Description HDR-30 is one economical ultra slim 30W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 35mm(2SU) in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 85VAC to 264VAC(277VAC operational) and conforms to BS EN/EN61000-3-2, the norm the European Union regulates for harmonic current. HDR-30 is designed with plastic housing that it can effectively prevent user from electric hazards. With working efficiency up to 90%, the entire series can operate at the ambient temperature between -30 and 70 under air convection. The complete protection functions and relevant certificates for home automations and industrial control apparatus (IEC62368-1, UL508,UL62368-1, BS EN/EN61558-2-16) make HDR-30 a very competitive power supply solution for household and industrial applications. Model Encoding HDR - 30 - 12 Downloaded from Arrow.com. Output voltage Rated wattage Series name File Name:HDR-30-SPEC 2022-12-02 30W Ultra Slim Step Shape DIN Rail HDR-30 series SPECIFICATION MODEL HDR-30-5 HDR-30-12 HDR-30-15 HDR-30-24 HDR-30-48 OUTPUT DC VOLTAGE 5V 12V 15V RATED CURRENT 3A 2A 2A CURRENT RANGE 0 ~ 3A 0 ~ 2A 0 ~ 2A RATED POWER 15W 24W 30W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 10.8 ~ 13.8V 13.5 ~ 18V VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% LINE REGULATION ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.0% ±1.0% ±1.0% SETUP, RISE TIME 500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 30ms/230VAC 12ms/115VAC at full load 24V 1.5A 0 ~ 1.5A 36W 150mVp-p 21.6 ~ 29V ±1.0% ±1.0% ±1.0% 48V 0.75A 0 ~ 0.75A 36W 240mVp-p 43.2 ~ 55.2V ±1.0% ±1.0% ±1.0% VOLTAGE RANGE 85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 82% 88% 89% 89% 90% AC CURRENT (Typ.) 0.88A/115VAC 0.48A/230VAC INRUSH CURRENT (Typ.) COLD START 25A/115VAC 45A/230VAC OVERLOAD PROTECTION 105 ~ 160% rated output power Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed ENVIRONMENT OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 5.75 ~ 7.5V 15 ~ 18V 18.8 ~ 22.5V 30 ~ 36V 57.6~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing ±0.03%/ (0 ~ 50) RH non-condensing 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE 2000 meters OVER VOLTAGE CATEGORY SAFETY STANDARDS WITHSTAND VOLTAGE ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1,IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV BS EN/EN62368-1 I/P-O/P:4KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted BS EN/EN55032(CISPR32), CNS13438 Class B EMC EMISSION Radiated BS EN/EN55032(CISPR32), CNS13438 Class B Harmonic Current BS EN/EN61000-3-2 Class A SAFETY & EMC (Note 4) Voltage Flicker BS EN/EN61000-3-3 BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3 Parameter Standard ESD BS EN/EN61000-4-2 ------- Test Level /Note Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility BS EN/EN61000-4-3 Level 3, criteria A EMC IMMUNITY EFT/Burest Surge BS EN/EN61000-4-4 BS EN/EN61000-4-5 Level 3, criteria A Level 4,2KV/L-N, criteria A Conducted BS EN/EN61000-4-6 Level 3, criteria A MTBF Magnetic Field BS EN/EN61000-4-8 Voltage Dips and interruptions BS EN/EN61000-4-11 3670.4K hrs min. Telcordia SR-332 (Bellcore) ; 968.1K hrs min. Level 4, criteria A 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods MIL-HDBK-217F (25) OTHERS DIMENSION 35*90*54.5mm (W*H*D) PACKING 0.12Kg;96pcs/12.5Kg/1.1CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1f & 47f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:HDR-30-SPEC 2022-12-02 Downloaded from Arrow.com. 30W Ultra Slim Step Shape DIN Rail Block Diagram HDR-30 series I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V O.L.P. CONTROL DETECTION CIRCUIT O.V.P. Derating Curve Output Derating VS Input Voltage 100 80 60 50 40 20 -30 0 10 20 30 40 50 60 70 (VERTICAL) AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 277 (operational) INPUT VOLTAGE (VAC) 60Hz LOAD (%) LOAD (%) Downloaded from Arrow.com. File Name:HDR-30-SPEC 2022-12-02 30W Ultra Slim Step Shape DIN Rail Mechanical Specification (Unit: mm , tolerance ± 0.5mm) 35 21 HDR-30 series 58.4 54.5 90 63.65 45.15 43 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin No. Assignment Pin No. Assignment 1 +V 2 -V Pin No. Assignment 3 AC/L 4 AC/N Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. 35 File Name:HDR-30-SPEC 2022-12-02