The Vimar 01415 2F+ Gateway is an IoT device designed for integrating the Due Fili Plus video door entry system with IP/LAN networks, cloud services, and applications for smartphones, tablets, or touch supervisors. It is designed for installation on a DIN rail (60715 TH35) and occupies 6 modules of 17.5 mm.
This gateway connects the Due Fili Plus bus to an Ethernet LAN network, allowing the video door entry system to be used with Vimar home automation systems. IP connectivity enables local and remote operations via dedicated Android/iOS applications.
Features
- Power Supply: From BUS terminals 1, 2 - rated voltage 28 Vdc.
- Absorption:
- Standby: 120 mA
- Transmission (to supervisor devices or mobile App): 300 mA
- LAN Connection: Via RJ45 socket outlet (10/100/1000 Mbps).
- Video Signal Level: Minimum -20 dBm on the bus for reception.
- Control Buttons: 5 backlit control buttons.
- Inputs:
- Input for landing call.
- Input for additional power supply (Elvox 6923, 28Vdc 0.5A INT only).
- Configuration: Dip switch for line termination impedance.
- Operating Conditions:
- Temperature: -5 to +40 °C (indoor use).
- Humidity: 10 - 80% (non-condensing).
- Protection Degree: IP30.
Connections
- LAN Network: RJ45 socket outlet.
- Ethernet Cable: UTP cable, CAT 5e or superior.
- Maximum Ethernet Cable Length: 100 m.
The gateway facilitates information transfer between the Due Fili Plus bus and an IP network. With an internet connection, cloud-enabled remote management functions are available for both installers and end-users.
Operation
- Configuration of the Due Fili Plus system.
- Association with touch screens (models 01420, 01422, and 01425).
- Firmware updating.
Functions Available from Touch Screen:
- Outdoor unit self-starting.
- Outdoor unit lock opening.
- Audio intercom calls.
- Activating system functions (e.g., stair light, auxiliary functions).
- System contacts list and favorites menu for quick access.
- Configurable video voicemail.
- Audio and video call settings adjustment.
- Input for landing bell.
- Support for CCTV integration.
- Support for remote call service on smartphone/tablet.
Auxiliary Power Supply Mode
The device's power supply mode is selected via a dedicated dip switch:
- [ON] (Switch 1): Power supply from auxiliary (AUX). If no voltage is present on AUX, the device is powered from the Due Fili bus.
- [OFF] (Switch 1): Exclusive power supply from AUX. The device is never powered from the Due Fili bus.
Note: To power the device solely via the Due Fili bus, place the dip switch to [ON].
Video Termination
To terminate the video signal, set the dip switches as follows:
- A [ON] OPEN: When the BUS cable enters terminals 1, 2 and continues to another internal unit.
- B [ON] 100: When a BUS cable with a characteristic impedance of 100 Ohms (Elvox 732I or 732H cable) enters terminals 1, 2 and the riser stops in the internal unit.
- C [ON] 50: When a BUS cable with characteristic impedance of 50 Ohms (Cat. 5 or Cat. 6 twisted pair cable) enters terminals 1, 2 and the riser stops in the internal unit.
Key Functions
The gateway features several function buttons with associated LEDs:
- [F1] Cloud-Gateway Connection Emergency Procedure:
- Press and hold [F1] (10 s) to reset network configuration in DHCP and re-establish Cloud connection.
- LED 1: [ON] when gateway is working properly; [OFF] when not working or Cloud is enabled but unreachable. Flashes during reset via Installer App.
- [F2] New IP Address Request & Gateway Reset:
- Briefly press [F2] to restart DHCP client and request a new IP address. No action if static IP is configured.
- LED 2: Permanently [ON] when an IP address is assigned; [OFF] if no address is assigned. Flashes when DHCP server is not present or reachable.
- Press and hold [F2] (10 s) for factory reset (all LEDs turn off).
- [F3] Firmware Updating & Gateway Restart:
- Manual Firmware Update: Press and hold [F3] (10 s) until LED 3 flashes. Connect PC via USB, copy update files to the 'UPDATE' drive, safely remove the drive, then press and hold [F3] (10 s) again. LED 3 remains [ON] during update. IMPORTANT: Do not remove power during update.
- Gateway Restart: Press and hold [F3] (10 s) until LED 3 flashes, then press and hold [F3] (10 s) again. LED 3 stays [ON] briefly before restart.
- LED 3: Indicates firmware update status.
- [F4] Configuration in Due Fili System:
- The gateway must be configured as primary in the Due Fili Plus bus.
- Press and hold [F4] (10 s) until LED 4 flashes.
- Assign ID: For Master panels, press the button to associate. For Alphanumeric panels, enter the desired ID and press confirm.
- LED 4: Remains [ON] to signal normal operation after ID assignment.
- [CONF] User Association Enabling:
- Briefly press [CONF]. LED 5 turns [ON] and stays lit.
- LED 5 turns [OFF] upon successful enabling or after 3 minutes if unsuccessful.
- N.B.: To enable gateway association with the Installer, the device must not be already configured. Repeated presses of [CONF] do not restart the procedure.
Installation Rules
- Installation must be performed by qualified personnel in compliance with local electrical installation regulations.
- The RJ45 network interface (10/100/1000 Mbps) must only be connected to a SELV (Safety Extra-Low Voltage) network.
WARNING: Update the firmware to the latest version! Download from www.vimar.com > Download > Software > View Pro. Version 1.13.1 can only be installed if version 1.12.1 was installed first. The View Pro App manual is available on www.vimar.com using the gateway article code.
Regulatory Compliance
- EMC Directive: Standards EN 60065, EN 61000-6-1, EN 61000-6-3.
- REACH Regulation (EU) No. 1907/2006: Article 33. The product may contain traces of lead.
- WEEE (Waste Electrical and Electronic Equipment): The crossed-out bin symbol indicates that the product must not be disposed of with general waste. Users must take it to appropriate separate collection centers or return it to the retailer. Free return is possible for products under 25 cm at retailers with sales areas of at least 400 m². Proper collection and disposal contribute to environmental protection and material recycling.
Diagram Descriptions
Front View
The front panel features:
- Terminal Covers: To be removed for wiring cables on terminals H and L.
- [USB Port]: For firmware updating.
- Buttons and LEDs:
- [F1] Button / LED 1
- [F2] Button / LED 2
- [F3] Button / LED 3
- [F4] Button / LED 4
- [CONF] Button / LED 5
- Terminal Blocks: Labeled 1, 2 (Bus Due Fili Plus), FP (Input for local landing call button), M (Earth reference for landing call button), E+ (Additional power supply input +), E- (Additional power supply input -).
- [ETH] Port: RJ45 socket for Ethernet cable connection.
- Dip Switches: Labeled 'I' for Video Termination and 'L' for Auxiliary Power Supply.
Connections
The gateway supports different connection configurations:
- In/Out Configuration: Shows wiring for connecting the gateway in a system where the bus cable continues to other units. This includes connections to the Due Fili Plus bus (terminals 1, 2), power supply (E+, E-), landing call button (FP, M), and Ethernet (ETH).
- Terminal Configuration: Illustrates wiring for systems where the bus cable terminates at the internal unit. Similar connections as above, with specific dip switch settings for video termination based on cable impedance (OPEN, 100 Ohm, 50 Ohm).
- Variant for Connecting the Landing Button: Details how to connect a normally open (NO) landing call button using the FP and M terminals.
CAUTION: The electrical installation of the gateway requires the connection of the supplementary power supply 6923, one for each gateway type 01415.
Integrated Infrastructure Example
This diagram illustrates how the Vimar 01415 2F+ Gateway integrates various Vimar and Elvox systems:
- System Integration: Connects to Vimar By-me Plus, By-alarm Plus systems, and Elvox Videocitofonia 2F+ and IP systems.
- Connectivity: Links these systems to the Cloud/Internet via LAN or WLAN networks.
- Other Devices: Shows potential connections to other gateways (e.g., 01410, 01411, 01416), IP routers, and touch screens (01420, 01422, 01425).
- Power: Indicates 12-30V power supply.
Key Function Details
- [F1] Cloud Connection / Reset: Pressing [F1] for 10s initiates an emergency procedure to reset network configuration in DHCP and re-establish Cloud connection. LED 1 indicates status.
- [F2] DHCP IP Request / Reset: Brief press of [F2] requests a new IP from DHCP. Long press (10s) performs a factory reset. LED 2 indicates IP assignment status.
- [F3] Firmware Update / Restart: Long press [F3] (10s) initiates firmware update or gateway restart. LED 3 indicates progress. Requires specific firmware version installation order.
- [F4] Due Fili Configuration: Long press [F4] (10s) to configure the gateway as primary in the Due Fili Plus bus and assign an ID. LED 4 indicates normal operation.
- [CONF] User Association: Brief press of [CONF] enables user association. LED 5 indicates status. Device must not be pre-configured.