Owner's Manual for MEAN WELL models including: RSP-1600-12 1600W Power Supply With Single Output, RSP-1600-12, 1600W Power Supply With Single Output, Power Supply With Single Output, Supply With Single Output, With Single Output, Single Output
MEAN-WELL USA, INC. - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 8 Pages, 402.04KB
DocumentDocument1600W Power Supply with Single Output Dimension L *W* H 300 * 85 * 41 (1U) mm 11.8 * 3.35 * 1.61 (1U) inch RSP-1600 series Front User's Manual Back R33100 RoHS CNS14336-1 UL62368-1 Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 TPTC004 IEC62368-1 Features Universal AC input / Full range (Withstand 300VAC surge input for 5 seconds) Built-in active PFC function High efficiency up to 93% Forced air cooling by built-in DC fan Output voltage and constant current level programmable Active current sharing up to 9600W (5+1) Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal / OTP alarm signal Protections: Short circuit / Overload / Over voltage / Over temperature Optional PMBus or CANBus protocol 5 years warranty Applications Factory control or automation apparatus Test and measurement instrument Laser related machine Aging facility Digital broadcasting Constant current source Redundant system GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Description RSP-1600 is a 1.6KW single output enclosed type AC/DC power supply with a 1U low profile and a high power density up to 25W/inch3. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the thermostatically controlled fan. Moreover, RSP-1600 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc. Model Encoding / Order Information RSP - 1600 - 48 Communication protocol option Output voltage (12V/24V/27V/36V/48V) Output wattage Series name Type Blank PM CAN Communication Protocol None PMBus protocol CANBus protocol Downloaded from Arrow.com. Note In Stock By request By request File Name:RSP-1600-SPEC 2022-12-26 1600W Power Supply with Single Output RSP-1600 series SPECIFICATION MODEL RSP-1600-12 RSP-1600-24 RSP-1600-27 RSP-1600-36 RSP-1600-48 DC VOLTAGE 12V 24V 27V 36V 48V RATED CURRENT CURRENT RANGE RATED POWER 125A 0 ~ 125A 1500W 67A 0 ~ 67A 1608W 59A 0 ~ 59A 1593W 44.5A 0 ~ 44.5A 1602W 33.5A 0 ~ 33.5A 1608W OUTPUT RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE ADJ. RANGE 11.5 ~ 15V VOLTAGE TOLERANCE Note.4 ±1.0% LINE REGULATION ±0.5% LOAD REGULATION ±0.5% 200mVp-p 23.5 ~ 30V ±1.0% ±0.5% ±0.5% 200mVp-p 26.5 ~ 33.5V ±1.0% ±0.5% ±0.5% 250mVp-p 35.5 ~ 45V ±1.0% ±0.5% ±0.5% 300mVp-p 47.5 ~ 58.8V ±1.0% ±0.5% ±0.5% SETUP, RISE TIME 1500ms, 60ms/230VAC at full load HOLD UP TIME (Typ.) 16ms / 230VAC at 75% load 10ms / 230VAC at full load VOLTAGE RANGE Note.5 90 ~ 264VAC 250 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.97/230VAC at full load INPUT EFFICIENCY (Typ.) 89% 91.5% 92% 92% 93% AC CURRENT (Typ.) Note.5 14A/115VAC 8A/230VAC 15A/115VAC 8.5A/230VAC INRUSH CURRENT (Typ.) COLD START 35A/230VAC LEAKAGE CURRENT <2mA / 230VAC OVERLOAD 105 ~ 115% rated current Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover PROTECTION OVER VOLTAGE 15.75 ~ 18.75V 31.5 ~ 37.5V 35.2 ~ 41.9V Protection type : Shut down o/p voltage, re-power on to recover 47.2 ~ 56.3V 63 ~ 75V OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down OUTPUT VOLTAGE Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V). PROGRAMMABLE(PV) Note 6 Please refer to the Function Manual. FUNCTION OUTPUT CURRENT Adjustment of constant current level is allowable to 20 ~ 100% of rated current. PROGRAMMABLE(PC) Note 6 Please refer to the Function Manual. AUXILIARY POWER 5V @ 0.3A, 12V @ 0.8A REMOTE ON-OFF CONTROL By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual REMOTE SENSE Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual ALARM SIGNAL Isolated signal output for T-alarm and DC OK WORKING TEMP. -30 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted BS EN/EN55032 (CISPR32) Class B EMC EMISSION SAFETY & EMC (Note 8) EMC IMMUNITY Radiated BS EN/EN55032 (CISPR32) Harmonic Current BS EN/EN61000-3-2 Voltage Flicker BS EN/EN61000-3-3 BS EN/EN55035, BS EN/EN61000-6-2, BSMI CNS13438 Parameter Standard ESD BS EN/EN61000-4-2 Radiated BS EN/EN61000-4-3 EFT / Burst BS EN/EN61000-4-4 Surge BS EN/EN61000-4-5 Class A Class A ----- Test Level / Note Level 3, 8KV air ; Level 2, 4KV contact Level 3 Level 3 Level 4, 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 MTBF Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods 478.8K hrs min. Telcordia SR-332 (Bellcore) ; 42.1K hrs min. MIL-HDBK-217F (25) OTHERS NOTE DIMENSION 300*85*41mm (L*W*H) PACKING 2.1Kg;6pcs/13.6Kg/1.25CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. PV/PC functions when users are not operating on PMBus/CANBus. SVR functions when users are neither operating on PMBus/CANBus nor using PV/PC. 7. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover. 8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 9. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:RSP-1600-SPEC 2022-12-26 1600W Power Supply with Single Output RSP-1600 series Block Diagram I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC POWER SWITCHING PFC CONTROL DETECTION CIRCUIT PWM CONTROL MCU O.T.P. AUX FAN POWER RECTIFIERS & FILTER O.V.P. DETECTION CIRCUIT MCU RECTIFIERS & FILTER PFC fosc : 90KHz PWM fosc : 70KHz ORING FET ORING FET CONTROL TRANSCEIVERS +S +V -V -S PV/PC DA/DB DATA ISOLATION 12V/0.8A AUX POWER 5V/0.3A T-Alarm DC-OK (SDA/SCL or CANH/CANL Remote ON-OFF ( Static Characteristics LOAD (%) 100 90 80 70 60 50 40 30 90 100 115 180 264 INPUT VOLTAGE (VAC) 60Hz INPUT MODEL 180~264VAC 12V 1500W 125A 24V 1608W 67A 27V 1593W 59A 36V 1602W 44.5A 48V 1608W 33.5A 115VAC 1200W 1286.4W 1274.4W 1281.6W 1286.4W 100A 53.6A 47.2A 35.6A 26.8A 100VAC 1050W 1125.6W 1115.1W 1121.4W 1125.6W 87.5A 46.9A 41.3A 31.15A 23.45A 90VAC 900W 75A 964.8W 955.8W 961.2W 964.8W 40.2A 35.4A 26.7A 20.1A LOAD (%) Derating Curve Efficiency vs Load (48V Model) 100 80 230VAC Input only 60 50 40 20 -30 -25 -10 0 15 30 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () EFFICIENCY (%) 94 93 92 91 90 89 88 87 86 85 84 83 82 81 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD The curve above is measured at 230VAC. File Name:RSP-1600-SPEC 2022-12-26 Downloaded from Arrow.com. 1600W Power Supply with Single Output Function Manual 1. Voltage Drop Compensation 1.1 Remote Sense The Remote Sense compensates voltage drop on the load wiring up to 0.5V RSP-1600 series PIN15 +S PIN16 -S +V LOAD -V -V CN1 +V Sense lines should be twisted in pairs to minimize noise pick-up. The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal. 1.2 Local Sense The +S,-S have to be connected to the +V(signal), -V(signal), respectively, as the following diagram, in order to get the correct output voltage if Remote Sense is not used. -V CN1 +V PIN13 +V(signal) PIN15 +S PIN14 -V(signal) PIN16 -S +V LOAD -V 2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed by applying EXTERNAL VOLTAGE. -V CN1 +V PIN12 PV PIN14 -V(signal) EXTERNAL VOLTAGE (DC) OUTPUT VOLTAGE(%) OUTPUT CURRENT (%) Vout 125 100 60 40 0 Non-Linear 12V Others 0.4 1 4.7 5 EXTERNAL VOLTAGE (DC) 100 80 60 40 20 V 40 60 80 100 125 V OUTPUT VOLTAGE (%) The rated current should change with the Output Voltage Programming accordingly. For Remote Sense / Local Sense, please refer to "Voltage Drop Compensation" section. File Name:RSP-1600-SPEC 2022-12-26 Downloaded from Arrow.com. 1600W Power Supply with Single Output RSP-1600 series 3. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim) The constant current level can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE. Iout 110 100 -V CN1 +V PIN11 PC PIN14 -V(signal) EXTERNAL VOLTAGE (DC) Non-Linear OUTPUT CURRENT (%) For Remote Sense / Local Sense, please refer to "Voltage Drop Compensation" section. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover. 20 0.4 1 V 4.7 5 EXTERNAL VOLTAGE (VDC) 4. Remote ON-OFF Control The power supply can be turned ON/OFF individually or along with other units by using the "Remote ON-OFF" function. -V CN1 +V PIN3 +5V-AUX switch PIN4 Remote ON-OFF Between Remote ON-OFF and +5V-AUX Switch Short Switch Open Power Supply Status ON OFF 5. Alarm Signal Output There are 2 alarm signals, DC OK and T-ALARM, in TTL signal form, on CN1. These signals are isolated from output. The maximum sink current is 10mA. -V CN1 +V PIN5 DC OK PIN6 T-ALARM PIN2 GND-AUX Application Circuit Downloaded from Arrow.com. File Name:RSP-1600-SPEC 2022-12-26 1600W Power Supply with Single Output RSP-1600 series 6.Current Sharing with Remote Sense RSP-1600 has the built-in active current sharing function and can be connected in parallel, up to 6 units, to provide higher output power as exhibited below : The power supplies should be paralleled using short and large diameter wiring and then connected to the load. Difference of output voltages among parallel units should be less than 0.2V. The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9 When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit) the current shared among units may not be balanced. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%. CN500/SW1 Function pin connection Parallel 1 unit 2 unit 3 unit 4 unit 5 unit 6 unit PSU1 CN500 SW1 X ON V ON V ON V ON V ON V ON PSU2 CN500 SW1 V ON V OFF V OFF V OFF V OFF PSU3 CN500 SW1 V ON V OFF V OFF V OFF PSU4 CN500 SW1 V ON V OFF V OFF PSU5 CN500 SW1 V ON V OFF PSU6 CN500 SW1 V ON (V : CN500 connected ; X : CN500 not connected.) RSP-1600 PSU1 RSP-1600 PSU2 RSP-1600 PSU3 -V -V -V TB1 +V TB1 +V TB1 +V RSP-1600 PSU4 -V TB1 +V RSP-1600 PSU5 -V TB1 +V RSP-1600 PSU6 -V TB1 +V Twisted wires -V +V LOAD Fig 5.1 13 5 DA DB -V(signal) DA DB -V(signal) 24 6 PSU1 CN500 13 5 DA DB -V(signal) DA DB -V(signal) 246 PSU2 CN500 13 5 DA DB -V(signal) DA DB -V(signal) 246 PSU3 CN500 13 5 DA DB -V(signal) DA DB -V(signal) 246 PSU4 CN500 If the lines of CN500 are too long, they should be twisted in pairs to avoid the noise. DA,DB and -V(signal) are connected mutually in parallel. For Remote Sense / Local Sense, please refer to "Voltage Drop Compensation" section. 13 5 DA DB -V(signal) DA DB -V(signal) 246 PSU5 CN500 13 5 DA DB -V(signal) DA DB -V(signal) 246 PSU6 CN500 Downloaded from Arrow.com. File Name:RSP-1600-SPEC 2022-12-26 1600W Power Supply with Single Output Mechanical Specification 30 5.8 252 29.6 21.6 20 2 13 2 15 9 10 4 1 2 28 -V 38 +V 15 16 78 12 LED SW1 SVR 1 2 I/P 3 6 2 6.5 2-M3 12 max. 5.8 252 (Top View) 252 300 16.8 105 16.8 22.8 115 22.8 RSP-1600 series Case No.250 Unit:mm 2-2.8 2-M4 L=5 2 43 Air flow direction 17 2 2-M4 L=5 2-2.8 41 85 CN1 CN500 1 1 70 (Bottom View) 3-M3 L=4 1 42.5 7.5 16.1 264.7 Mounting Instruction Hole No. Recommended Screw Size 1 M3 2 M4 MAX. Penetration Depth L 4mm 5mm Recommended mounting torque 6~8Kgf-cm 7~10Kgf-cm Control Pin No. Assignment(CN1) : HRS DF11-16DP-2DS or equivalent 1 15 2 16 Mating Housing HRS DF11-16DS or equivalent Terminal HRS DF11-**SC or equivalent Mounting Surface Mounting Screw Chassis of RSP-1600 Pin No. Function Description 1 +12V-AUX Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin2). The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by "Remote ON-OFF". 2 GND-AUX Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V). 3 +5V-AUX Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin2). The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by "Remote ON-OFF 4 Remote The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF and +5V-AUX. (Note.2) ON-OFF Short (4.5 ~ 5.5V) : Power ON ; Open (-0.5 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V. High (3.5 ~ 5.5V) : When the Vout 77%±5%. 5 DC-OK Low (-0.5 ~ 0.5V) : When Vout 80%±5%. The maximum sourcing current is 10mA and only for output. (Note.2) 6 7,8,9 T-ALARM NC A0,A1,A2 High (3.5 ~ 5.5V) : When the internal temperature exceeds the limit of temperature alarm, or when Fan fails. Low (-0.5 ~ 0.5V) : When the internal temperature is normal, and when Fan normally works. The maximum sourcing current is 10mA and only for output(Note.2) For standard model: Retain for future use. For PMBus / CANBus model: PMBus / CANBus interface address lines. (Note.1) 10 NC Retain for future use. 11 PC Connection for constant current level programming. (Note.1) 12 PV Connection for output voltage programming. (Note.1) 13 +V (Signal) Positive output voltage signal. It is for local sense; it cannot be connected directly to the load. 14 -V (Signal) Negative output voltage signal. It is for local sense and certain function reference; it cannot be connected directly to the load. 15 +S Positive sensing for remote sense. 16 -S Negative sensing for remote sense. Note.1: Non-isolated signal, referenced to [-V(signal)]. Note.2: Isolated signal, referenced to GND-AUX. Downloaded from Arrow.com. File Name:RSP-1600-SPEC 2022-12-26 1600W Power Supply with Single Output RSP-1600 series LED Status Indicators LED Green Red Description The power supply functions normally. Abnormal status (Over temperature protection, Overload protection, Fan fail.) AC Input Terminal Pin No. Assignment Pin No. Assignment Diagram 1 FG 2 AC/N 3 AC/L Maximum mounting torque 8Kgf-cm Control Pin No. Assignment(CN500) : HRS DF11-8DP-2DS or equivalent 17 28 Mating Housing HRS DF11-8DS or equivalent Terminal HRS DF11-**SC or equivalent Pin No. Function Description 1,2 DA Differential digital signal for parallel control. 3,4 DB Differential digital signal for parallel control. 5,6 -V (Signal) Negative output voltage signal. It is for certain function reference; it cannot be connected directly to the load. NC For standard model: None. 7 SDA For PMBus model: Serial Data used in the PMBus interface. (Note) CANH For CANBus model: Data line used in CANBus interface. (Note) NC For standard model: None. 8 SCL For PMBus model: Serial Clock used in the PMBus interface. (Note) CANL For CANBus model: Data line used in CANBus interface. (Note) Note: Isolated signal, referenced to GND-AUX. Control Pin No. Assignment(SW1) Pin No. 1,2 Function Description Terminal resistance SW1 is the selector of terminal resistor that is designed for DA/DB signals and parallel control function. Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:RSP-1600-SPEC 2022-12-26