Installation Guide for ATLONA models including: AT-OCS-900N Network Enabled Occupancy Sensor, AT-OCS-900N, Network Enabled Occupancy Sensor, Enabled Occupancy Sensor, Occupancy Sensor

Installation Guide

[PDF] Installation Guide - avbportal.com

60 ft. (18.3 m). 20 ft. (6.1 m). 40 ft. (12.2 m). 60 ft. (18.3 m). 0. 8 ft. (2.4 m). 10 ft. (3.0 m). 12 ft. (3.7 m). 0. 20 ft. (6.1 m). 15 ft. (4.6 m). 10 ft.


File Info : application/pdf, 4 Pages, 741.19KB

PDF preview unavailable. Download the PDF instead.

282c52dc-eeb6-4e45-b151-a79e7ca638e7
Network-Enabled Occupancy Sensor
AT-OCS-900N

Installation Guide
AT-OCS-900N

The Atlona AT-OCS-900N is a network-enabled multi-function sensor designed for use in a wide variety of AV automation applications. This ceiling mounted sensor uses passive infrared (PIR) technology to detect occupancy in the coverage area. The OCS-900N utilizes an IP network to communicate with select Atlona products and the VelocityTM system to automatically control AV components based on whether the space is occupied. It comes with two lenses that cover approximately 900 or 2,000 square feet depending on ceiling height. A blinder insert is included that limits the sensor's field of view, preventing detection in unwanted areas such as doorways or windows with heavy cross traffic. Installation is simplified by Power over Ethernet (PoE), that provides both communications and power over a single cable as well as spring-loaded clamps that secure the sensor to a ceiling tile.
In addition to occupancy, the OCS-900N also captures temperature and ambient light level information. Its open standard design allows sensor information to be communicated to third-party ventilation, lighting, and other systems over TCP/IP using common protocols such as UDP, TCP, WebSocket, and MQTT.
Package Contents 1 x AT-OCS-900N with installed Standard Ceiling lens 1 x 120-degree optics shader 1 x High Ceiling lens 1 x Installation guide
IMPORTANT: Visit http://www.atlona.com/product/AT-OCS-900N for the latest firmware updates and documentation.
1

Installation Guide
AT-OCS-900N
Installation 1. Determine the coverage area required. Refer to Coverage Pattern (page 3) for
more information. 2. Connect an Ethernet cable from the LAN port to the Local Area Network.
2

3. In a pre-drilled 2.5" hole, fold the wing clips towards the center of the AT-OCS-900N. The recommended mounting hold diameter is 2.5" and should not exceed a diameter of 2.90". Refer to Figure 1.1 for dimensions of the AT-OCS-900N.
4. Insert the device into the ceiling tile and release clips. The wing clips will return to the down position, securing the unit in place.

C E I L I N G

3

3

4
4
C E I L I N G

Figure 1.1

IMPORTANT: Do not touch or apply pressure to the IR sensor. Doing so may damage or break the IR sensor.
2

Installation Guide
AT-OCS-900N

Coverage Pattern

The AT-OCS-900N includes a factory-installed Standard Ceiling lens. The Standard Ceiling lens can be replaced with the included High Ceiling lens, depending on the size of the room. Refer to the diagrams below for coverage area and the User Manual for lens removal instructions.

Standard Ceiling Coverage

High Ceiling Coverage

Top View

Top View

15 ft (4.6 m)

60 ft (18.3 m)

10 ft (3.0 m)

40 ft (12.2 m)

5 ft (1.5 m)

20 ft (6.1 m)

0

0

5 ft (1.5 m)
10 ft (3.0 m)
15 ft (4.6 m)

20 ft (6.1 m)
40 ft (12.2 m)
60 ft (18.3 m)

Side View
0

8 ft (2.4 m)

10 ft (3.0 m)

12 ft (3.7 m)

20 ft

15 ft

10 ft

5 ft

0

5 ft

10 ft

15 ft

20 ft

(6.1 m)

(4.6 m)

(3.0 m)

(1.5 m)

(1.5 m)

(3.0 m)

(4.6 m)

(6.1 m)

Side View
0

20 ft (6.1 m)
30 ft (9.1 m)
40 ft (12.2 m)

40 ft

30 ft

20 ft

10 ft

0

10 ft

20 ft

30 ft

40 ft

(12.2 m) (9.1 m)

(6.1 m)

(3.0 m)

(3.0 m)

(6.1 m)

(9.1 m) (12.2 m)

Accessing the Web Server
The AT-OCS-900N includes a built-in web server, which allows easy management and control of all features.
1. Verify that the AT-OCS-900N, and the computer used to manage the AT-OCS-900N, are connected to the same network.
2. Launch a web browser and enter the IP address of the unit. 3. The Registration page will be displayed. 4. Enter the username, password, and confirm the password on the registration page
to register the device. Both the username and password must consist of 5 - 16 alphanumeric characters/symbols. 5. Click on Register button. 6. After clicking the register button, the dashboard of the built-in web server will be displayed.

3

Version 2

Installation Guide
AT-OCS-900N
Warranty To view the product warranty, use the following link or QR code: https://atlona.com/warranty/.
English Declaration of Conformity The English version can be found under the resources tab at: https://atlona.com/product/at-ocs-900n/.
Chinese Declaration of Conformity RoHS SKU: https://atlona.com/about-us/china-rohs/.

25280-R2

Toll free US

International

atlona.com · 877.536.3976 · 41.43.508.4321

© 2021 Atlona Inc. All rights reserved. "Atlona" and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered trademarks are the property of their respective owners. Pricing, specifications and availability subject to change without notice. Actual
products, product images, and online product images may vary from images shown here.

4



References

Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Windows)