SC-UN – Universal Source Controllers www.eaton.com/lightingsystems. Wiring Diagram. iCANnet. iCANnet. SWITCH INPUT 2. SWITCH INPUT 1.
Technical Data iILNSu#min SC-UN Universal Source Controllers Catalog# Project Comments Prepared by Date Type Overview The Universal Source Controller line of lighting control panels set a new standard in architectural lighting control. Each Source Controller contains individual control cards that are the industry's only "true universal" by controlling most load types without interface or multiple cards. In addition, each panel has onboard Ethernet, A/V interface, Contact Closure, DMX input, voltage sensing, real-time individual circuit power metering, and Phase SenseTM technology designed to ensure control even during individual phase failure. Features 6, 12, and 24 circuit variants Forward Phase triac slow rise-time dimmer engine. Capable of withstanding repetitive inrush current of 50 times operating current without impacting lifetime of dimmer or relay. Positive air-gap off per circuit Single or three phase versions Continuous duty, thermal magnetic SWD rated breakers for each circuit Bypass per circuit for manual override and providing construction site lighting Voltage and frequency compensation to maintain light level during supply fluctuations Real-time power metering for each circuit, phase, and the total panel Live feed per circuit, via breaker, for emergency lighting connection July 2015 SC-UN Universal Source Controllers Specifications Mechanical Programming Interfacing Standards No regular maintenance requirements due to natural convection cooling, i.e. no fans or filters Single circuit dimmer card Wall mounted design An LCD graphical user interface and keypad for ease of programming and configuration. The interface can be used for programming single area systems there is no need to use a PC. The GUI also allows programming of the astronomical timeclock. All SC-UN Source Controllers have RS485 and Ethernet over UDP connections to allow for control by third party systems (Building Management System, Audio/Visual, etc.) through the use of open protocol ASCII message commands Two contact closure inputs for integration with auxiliary equipment and emergency lighting input DMX512 input for control by entertainment systems Power metering information is available via Ethernet over UDP through the use of open protocol ASCII message commands 37.2 in. (945 mm) Dimensions (Inches/mm) 6 Circuit 20.3 in. (517 mm) 6 Channel 12 Circuit 20.3 in. (517 mm) 7.6 in. (193 mm) 7.6 in. (193 mm) 24 Circuit 27.8 in. (707 mm) 37.2 in. (945 mm) 56.7 in. (1440 mm) 56.7 in. (1440 mm) Load Types 6 Circuit 20.3 in. (517 mm) Incandescent Magnetic and Forward Phase electronic low voltage - Factory Approved Transformer only. Neon / cold cathode Non-dim (switched) Analog fluorescent ballast control -- 2-wire fluorescent loads -- 3-wire fluorescent loads (Lutron ECO-10 and Hi-Lume) -- 4-wire fluorescent loads, 0-10 VDC Isolated (40 µA max per circuit leakage to line) 6 Channel Each 0-10V output supports up to 50 ballasts/driver1s2tChairtcudirtaw the standard 2mA each 20.3 in. (517 mm) 7.6 in. (193 mm) 7.6 in. (193 mm) 12 Channel 24 Circuit 27.8 in. (707 mm) 7.6 in. (193 mm) 18 & 24 Channe 56.7 in. (1440 mm) 56.7 in. (1440 mm) 2 www.eaton.com/lightingsystems 12 Channel 18 & 24 Channel SC-UN Universal Source Controllers Wiring Diagram POWER FEED 120V and 277V options, Single or 3 Phase options LOAD WIRING DIMMING NON-DIM / SWITCHED 2-WIRE FLUORESCENT 3-WIRE FLUORESCENT Feed Wiring Applicaiton 24 Channel 3-phase Panel Phase Neutral Earth 12 Channel 3-phase Panel Phase Neutral Earth 12 Channel 1-phase Panel Phase Neutral Earth Wire Range (AWG) 4/0-6 350 MCM - 6 2-14 2/0-12 2/0-12 2-14 350 MCM - 6 350 MCM - 6 2-14 ETHERNET LINK RS485 DMX IN SWITCH INPUT 1 SWITCH INPUT 2 0-10V for 4-WIRE for Dimmable Fluorescent, LED's, HID iCANnet iCANnet iCANnet cable type Cooper LCCNP (Non Plenum) Cable or LCCP (Plenum) or Belden 1502R (Non Plenum) or 1502P (Plenum). Each Source Controller can power up to 10 wallstations/devices. For more than 10 wallstations/devices per Source Controller add a 15 VDC External Power Supply. Wallstations/devices must be within 1,000 ft. of the Source Controller. For wallstations/devices further from a Source Controller add a 15 VDC External Power Supply. 100 Devices per physical segment on iCANnet, maximum segment distance of 1000m/3200ft. A BN-2-NA can be added to combine more than 100 devices together (up to 65,000 total) and to extend network cable distance. Applicaiton 6 Channel 3-phase Panel Phase Neutral Earth 6 Channel 3-phase Panel Phase Neutral Earth Maximum BTU Dissipation 6 Circuit Unit 12 Circuit Unit 24 Circuit Unit 1050 BTU @ 100% 2100 BTU @ 100% 4200 BTU @ 100% Wire Range (AWG) 2/0-12 2/0-12 2-14 2/0-14 2/0-14 2-14 July 2015 Amp Rating per Pole 128 192 N/A 64 96 N/A 192 288 N/A Amp Rating per Pole 32 48 N/A 69 144 N/A www.eaton.com/lightingsystems 3 July 2015 SC-UN Universal Source Controllers Sample System Topology DRY CONTACT CLOSURE LOCAL PC REMOTE PC SC277-12-UN-3P-ML-20 INTERNET ROUTER LAPTOP SECURITY OCCUPANCY AV SYSTEM SENSOR COMPONENTS WiFi ETHERNET CLS-4TSB-RL-W-IR Scene 1 Scene 2 Scene 3 Scene 4 UIG-2-NA RS232 SI-2-NA Each Source Controller can power up to 10 wallstations/devices. These devices must be within 1000ft of the Source Controller. For devices further from a Source Controller add a 15 VDC power supply. 100 devices/addresses per physical segment on iCANnet (BN-2-NA can be added to combine more than 100 devices together, up to 65,000 total) SC277-24-UN-3P-ML-20 TUNGSTEN DISCHARGE DMX OUTPUT CONSOLE BY ZERO 88 OR OTHERS DMX512 2, 3 & 4 WIRE FLUORESCENT COLD CATHODE COLOR CHANGING FIXTURES DRY CONTACT CLOSURE CONTACT CLOSURE INPUT CLS-3TLB-W-IR Scene 1 Scene 2 Scene 3 HH17IR CLS-1TLB-W-IR Scene 1 iCANnet Cable type - Cooper LCCNP (NON PLENUM) OR Cooper LCCP (PLENUM) Cable or BeldenTM 1502R (NON PLENUM) or 1502P (PLENUM) Maximum segement distance of 1000m/3200ft per segment SC120-12-UN-1P-ML-20 CRESTRON AMX RS485 Contact closure input TUNGSTEN DISCHARGE 2, 3 & 4 WIRE FLUORESCENT COLD CATHODE COLOR CHANGING FIXTURES CLV-44-RL-W-IR CLV-40-RL-W-IR CLV-44Z-RL-W-IR HH17IR Each Source Controller can power up to 10 wallstations/devices. These devices must be within 1000ft of the Source Controller. For devices further from a Source Controller add a 15 VDC power supply. 100 devices/addresses per physical segment on iCANnet (BN-2-NA can be added to combine more than 100 devices together, up to 65,000 total) SC120-06-UN-1P-ML-20 TUNGSTEN DISCHARGE 2, 3 & 4 WIRE FLUORESCENT COLD CATHODE COLOR CHANGING FIXTURES TSC-30-SS-NA 9Vdc SUPPLY NS3-C Combination Sensor iCANnet Cable type - Cooper LCCNP (NON PLENUM) OR Cooper LCCP (PLENUM) Cable or BeldenTM 1502R (NON PLENUM) or 1502P (PLENUM) Maximum segement distance of 1000m/3200ft per segment TUNGSTEN DISCHARGE 2, 3 & 4 WIRE FLUORESCENT COLD CATHODE COLOR CHANGING FIXTURES Ordering Catalog # SC120-06-UN-1P-ML-20 SC120-12-UN-1P-ML-20 SC120-06-UN-3P-ML-20 SC120-12-UN-3P-ML-20 SC120-24-UN-3P-ML-20 SC277-06-UN-1P-ML-20 SC277-06-UN-3P-ML-20 SC277-12-UN-3P-ML-20 SC277-24-UN-3P-ML-20 Description Universal 120V Cabinet with 6 Circuits for Most Loads, Single Phase, Main Lugs, 16A per Circuit Universal 120V Cabinet with 12 Circuits for Most Loads, Single Phase, Main Lugs, 16A per Circuit Universal 120V Cabinet with 6 Circuits for Most Loads, 3 Phase, Main Lugs, 16A per Circuit Universal 120V Cabinet with 12 Circuits for Most Loads, 3 Phase, Main Lugs, 16A per Circuit Universal 120V Cabinet with 24 Circuits for Most Loads, 3 Phase, Main Lugs, 16A per Circuit Universal 277V Cabinet with 6 Circuits for Most Loads, Single Phase, Main Lugs, 16A per Circuit Universal 277V Cabinet with 6 Circuits for Most Loads, 3 Phase, Main Lugs, 16A per Circuit Universal 277V Cabinet with 12 Circuits for Most Loads, 3 Phase, Main Lugs, 16A per Circuit Universal 277V Cabinet with 24 Circuits for Most Loads, 3 Phase, Main Lugs, 16A per Circuit SC - 120 - 12 - UN - 1P - ML - 20 Product SC Source Controller Voltage 120V, 277V Number of Circuits Source Controller Type UN = All Loads Branch Breaker Rating (Amps) Panel Feed ML = Main Lugs Phase 1P = Single Phase 3P = 3 Phase Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503022EN July 10, 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners.Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Windows)