Avantco Refrigeration User Manual

Commercial Refrigerator And Freezer User's Manual

This manual provides essential information for the setup, operation, and maintenance of Avantco commercial refrigerators and freezers.

Models Covered:

Please read this manual thoroughly prior to equipment set-up, operation, and maintenance.

Warning

DANGER – RISK OF FIRE OR EXPLOSION. Flammable refrigerant used. To be repaired only by trained service personnel. Do not puncture refrigerant tubing.

PELIGRO - RIESGO DE INCENDIO O EXPLOSION. Refrigerante inflamable utilizado. Para ser reparado solamente por personal de servicio calificado. No pinchar la tubería refrigerante.

DANGER – RISQUE DE FEU OU D'EXPLOSION. Le frigorigène est inflammable. Confier les réparations à un technicien spécialisé. Ne pas perforer la tubulure contenant le frigorigène.

CAUTION – RISK OF FIRE OR EXPLOSION. Flammable refrigerant used. Consult repair manual/owner's guide before attempting to service this product. All safety precautions must be followed.

ATENCION - RIESGO DE INCENDIO O EXPLOSIÓN. Refrigerante inflamable utilizado. Consulte el manual de reparación / guía del propietario antes de intentar dar servicio a este producto. Deben cumplir con todas las precauciones de seguridad.

ATTENTION – RISQUE DE FEU OU D'EXPLOSION. Le frigorigène est inflammable. Consulter le manuel du propriétaire/guide de réparation avant de tenter une réparation. Toutes les mesures de sécurité doivent être respectées.

CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; Follow handling instructions carefully. Flammable refrigerant used.

ATENCION - RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACION DE LA TUBERÍA REFRIGERANTE; Siga las instrucciones de manipulación con cuidado. Refrigerante inflamable utilizado.

ATTENTION – RISQUE DE FEU OU D'EXPLOSION SI LA TUBULURE CONTENTANT LE FRIGORIGÈNE EST PERFORÉE; Suivre les instructions de manutention avec soin. Le frigorigène est inflammable.

CAUTION – RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. Follow handling instructions carefully in compliance with local government regulations.

ATENCIÓN – RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A REFRIGERANTE INFLAMABLE UTILIZADO. Siga las instrucciones de manipulación con cuidado conforme a las reglas de la municipalidad.

ATTENTION – RISQUE DE FEU OU D'EXPLOSION SI LE FRIGORIGÈNE EST INFLAMMABLE. Suivre les instructions de manutention avec soin conformément aux réglementation gouvernementale locaux.

Installation

Important!!! Please Read Before Installation

Cabinet Location Guidelines

Electrical

Temperature Controls

Functions

Adjusting the Temperature

Your new refrigerator or freezer is already factory-set to run at optimum temperatures for food safety and should require no adjustments.

Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit.

Freezers are set to cycle between a minimum temperature of -5 degrees Fahrenheit and a maximum temperature of 2 degrees Fahrenheit.

Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not run constantly at this setting. To change it, follow these instructions:

Digital Control Units

Always remember to calculate the differential if you change the minimum temperature setting. The cabinet temperature will fluctuate up to +7 degrees over your set minimum temperature as the compressor runs and shuts off. Setting the temperature too high will result in unsafe maximum temperatures.

Freezer Control Diagram

[Diagram showing Freezer Control panel with digital display and buttons]

Refrigerator Control Diagram

[Diagram showing Refrigerator Control panel with digital display, power button, set button, and arrow buttons]

Loading Product

Before loading shelves, please be sure that all shelf clips are completely fastened in their correct locations. It is important that all shelves rest completely level before stocking your cabinet with product.

In order to maintain correct air flow inside the unit, please be sure to leave two to four (2 to 4) inches of space between the back wall and stored product. Blocking the evaporator fans will result in a warmer cabinet temperature, and ultimately compressor failure.

Running a Manual Defrost Cycle

This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to run a manual defrost cycle at any time, please follow the steps below:

Defrost Systems

Refrigerator coils are kept below the freezing point (32° F). During compressor down-time, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan and evaporated. Freezer coils are defrosted electrically. Automatic defrost timers automatically initiate at pre-set intervals and for a pre-determined duration.

Safety / Warning

Please pay close attention to the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit.

Attention

Unplug Cord

Proper Grounding Required

Warning

Regular Maintenance

WARNING: DISCONNECT POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.

Cleaning The Condenser Coil

Cleaning The Fan Blades and Motor

If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.

Cleaning The Interior of Unit

Troubleshooting

Compressor Not Running

Problem Solution
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord.
Thermostat set too high. Set thermostat to lower temperature.
Cabinet in defrost cycle. Wait for defrost cycle to finish.

Condensing Units Run For Long Periods of Time.

Problem Solution
Excessive amount of warm product placed in cabinet. Allow adequate time for product to cool down.
Prolonged door opening or door ajar. Ensure doors are closed when not in use. Avoid opening doors for long periods of time.
Door gasket(s) not sealing properly. Ensure gaskets are snapped in completely. Remove gasket and wash with soap and water. Check condition of gasket and replace if necessary.
Dirty condenser coil. Clean the condenser coil.
Evaporator coil iced over. Unplug unit and allow coil to defrost. Make sure thermostat is not set too cold. Ensure that door gasket(s) are sealing properly.

Cabinet Temperature is too Warm.

Problem Solution
Thermostat set too warm. Set thermostat to lower temperature.
Airflow blocked. Re-arrange product to allow for proper air flow. Make sure there is at least four inches of clearance from evaporator.
Excessive amount of warm product placed in cabinet. Allow adequate time for product to cool down.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Dirty condenser coil. Clean the condenser coil.
Evaporator coil iced over. Ensure doors are closed when not in use. Avoid opening doors for long periods of time.
Models: 178AU27FHC, 178AU27RHC, 178AU48FHC, 178AU48RHC, 178AU27FHC Commercial Refrigerator, 178AU27FHC, Commercial Refrigerator, Refrigerator

File Info : application/pdf, 8 Pages, 487.50KB

PDF preview unavailable. Download the PDF instead.

au series manual 1 Adobe PDF Library 16.0.7 Adobe InDesign 17.4 (Macintosh)

Related Documents

Preview Avantco AU-48F-HC 48" Undercounter Freezer - Technical Specifications and Details
Detailed specifications, features, and technical data for the Avantco AU-48F-HC 48-inch undercounter freezer, including dimensions, capacity, performance, and certifications.
Preview Avantco SS-UC-48F-HC 48" Undercounter Freezer - Technical Specifications and Features
Detailed specifications, features, and technical data for the Avantco SS-UC-48F-HC 48" Undercounter Freezer. Includes dimensions, performance data, certifications, and material information.
Preview Avantco A-49F-HC 54" Solid Door Reach-In Freezer - Technical Specifications
Detailed specifications for the Avantco A-49F-HC 54" Solid Door Reach-In Freezer, including dimensions, features, certifications, and technical data. This unit is designed for commercial refrigeration needs.
Preview Avantco A Plus AP-49F 55 3/8" Stainless Steel Solid Door Reach-In Freezer Spec Sheet
Detailed specifications for the Avantco A Plus AP-49F, a 55 3/8" stainless steel solid door reach-in freezer. Features include a durable stainless steel exterior and interior, digital temperature control, automatic defrost, and adjustable shelves. Ideal for commercial environments, this freezer operates on R-290 refrigerant and requires a 115V connection.
Preview Avantco ADC-8F-HC 49" Customizable Ice Cream Dipping Cabinet with Flat Sneeze Guard
Information on the Avantco ADC-8F-HC 49" Customizable Ice Cream Dipping Cabinet with Flat Sneeze Guard, including features, technical specifications, and certifications. This unit displays up to 8 ice cream tubs and has space for 6 back-up tubs, with a flat-front sneeze guard for visibility and contamination prevention. It maintains temperatures between -15 and 10 degrees Fahrenheit and uses R-290 refrigerant.
Preview Avantco GDC-24F-HC 31" Black Customizable Merchandiser Freezer with LED Lighting Spec Sheet
Detailed specifications for the Avantco GDC-24F-HC 31" Black Customizable Swing Glass Door Merchandiser Freezer with LED Lighting, including dimensions, features, and certifications.
Preview Avantco A-19F-HC 29" Solid Door Reach-In Freezer Spec Sheet
Detailed specifications for the Avantco A-19F-HC 29" Solid Door Reach-In Freezer, including features, technical data, and certifications. This freestanding freezer offers a 17.3 cu. ft. capacity, bottom-mounted 2/3 hp compressor with R-290 refrigerant, and a digital temperature controller.
Preview Avantco A Plus AP-49F 55 3/8" Stainless Steel Solid Door Reach-In Freezer Spec Sheet
Detailed specifications for the Avantco A Plus AP-49F, a 55 3/8" stainless steel solid door reach-in freezer. Features include North American manufacturing, durable stainless steel construction, digital controls, automatic defrost, and adjustable shelves.