TCL High Static Ducted System

Reach Every Corner of Your Space

Strong Performance | Easy Installation | Smart Control

Available Capacities: 7.1kW | 8.5kW | 10kW | 12.5kW | 14kW | 16kW

Key Features

Learn more at www.tcl.com/au

7 Year Warranty (Limited time only. T&Cs apply. Visit for more details.)

Specifications of Ducted System

Specification R32 7.1KW
TCD71D1HWH-DV
R32 8.5KW
TCD85D1HWH-DV
R32 10.0KW
TCD100D1HWH-DV
R32 12.5KW
TCD125D1HWH-DV
R32 14KW
TCD140D1HWH-DV
R32 16KW
TCD160D1HWH-DV
Indoor Unit Model TCD71D1HWH-DVI TCD85D1HWH-DVI TCD100D1HWH-DVI TCD125D1HWH-DVI TCD140D1HWH-DVI TCD160D1HWH-DVI
Outdoor Unit Model TCD71D1HWH-DVO TCD85D1HWH-DVO TCD100D1HWH-DVO TCD125D1HWH-DVO TCD140D1HWH-DVO TCD160D1HWH-DVO
Type Heat pump
Control type Wired controller standard with 15m cable
Power supply (Indoor/Outdoor Unit) 1 phase, 220-240 V, 50 Hz
Rated Capacity Cool(kW) 7.1 8.5 10.5 12.5 14 16
Rated Capacity Heat(kW) 7.5 10 12.5 15 16.5 19
Capacity Range Cool(kW) 3.1-11 3.1-12.3 4.0-12.8 4.0-13.5 4.1-16 4.1-17.8
Capacity Range Heat(kW) 3.3-12 3.3-13.5 4.3-15 4.3-15.8 6.0-17.3 6.0-19.2
Power input (Rated) Cool(kW) 1.90 2.44 2.48 3.77 3.85 4.86
Power input (Rated) Heat(kW) 1.73 2.52 2.9 3.75 4.2 4.94
EER Cool(kW/kw) 3.78 3.48 4.23 3.31 3.64 3.29
COP Heat(kw/kw) 4.38 3.96 4.31 4.00 3.96 3.85
AEER Cool 3.73 3.44 4.19 3.28 3.61 3.27
ACOP Heat 4.32 3.92 4.27 3.96 3.93 3.83
TCSPF(Residential) 5.4/5.01/5.2 5.14/4.71/4.92 5.55/5.08/5.18 4.71/4.37/4.56 5.23/4.85/5.05 4.77/4.47/4.67
HSPF(Residential) 4.71/4.32/3.95 4.72/4.16/3.65 4.85/4.44/3.91 4.63/4.10/3.52 4.44/4.03/3.6 4.49/3.94/3.45
Indoor unit Dimensions H×W×D (mm) 245×1200×700 245×1200×700 380×1510×945 380×1510×945 380×1510×945 380×1510×945
Indoor unit Packing dimensions H×W×D (mm) 310×1380×830 310×1380×830 455×1620×1010 455×1620×1010 455×1620×1010 455×1620×1010
Supply air opening flange HxW (mm) 149×1022 149×1022 245×1152 245×1152 245×1152 245×1152
Return air opening HxW (mm) 215×1091 215×1091 2×400(Oval) 2×400(Oval) 2×400(Oval) 2×400(Oval)
Indoor net weight (kg) 37 37 66 66 66 66
Indoor Gross weight (kg) 42 42 77 77 77 77
Airflow Rate(H/M/L) (L/S) 560/435/275 560/435/275 785/650/460 785/650/460 1120/950/780 1120/950/780
Sound pressure level@1.5m (dB(A)) 44 44 47 47 48 48
External Static Pressure (Rated) (Pa) 25 37 37 50 50 50
External Static Pressure(Range) (Pa) 0-200 0-200 0-200 0-200 0-200 0-200
Outdoor Unit Dimensions H×W×D (mm) 910×804×378 910×804×378 1010×858×436 1010×858×436 1330 × 950 × 340 1330 x 950 × 340
Outdoor Unit Packing dimensions H×W×D (mm) 1022x955x480 1022x955x480 1135x970x530 1135x970x530 1465 ×1080 × 430 1465 ×1080 × 430
Outdoor net weight (kg) 53 53 73 73 101 101
Outdoor Gross weight (kg) 57 57 85 85 107.5 107.5
Compressor Type Rotary
Sound pressure level Cooling / Heating (dB(A)) 56/57 56/57 57/58 57/58 58/59 58/59
Night quiet mode (dB(A)) None None 54 54 55 55
Sound power level (dB(A)) 67 67 70 70 74 74
Piping connection Liquid (mm) 09.52/3/8"
Piping connection Gas (mm) 15.88/5/8"
Refrigerant control EEV
Ref. piping Max length (m) 50 50 50 50 75 75
Ref. piping Max height difference (m) 25 25 30 30 30 30
Refrigerant Type R32
Pre-charge pipe length (m) 20
Extra charge (g/m) 30
Cooling temperature (°C) 16-50
Heating temperature (°C) -15-24
Power supply side Outdoor unit

Product Highlights

200PA High Static Pressure

Featuring a Sirocco fan turbine, efficient motor, and optimized duct design, this system delivers strong, consistent airflow, perfect for larger spaces or long duct runs.

[Diagram: Illustration showing a Sirocco fan turbine and ductwork.]

Split Design | Easy Installation

The modular split design, featuring a separate heat exchanger, motor section, and fan cover, offers enhanced flexibility and ease of installation, making it ideal for tight or complex spaces.

[Diagram: Exploded view of the indoor unit showing separate components.]

Built-in Condensate Pump

The built-in condensate pump automatically removes moisture, providing efficient drainage and preventing condensate buildup.

[Diagram: Illustration of a condensate pump with water being pumped away.]

48°C Self-cleaning

The evaporator features a self-cleaning process that includes dewing, frosting, defrosting, drying, and 48°C sterilizing to eliminate bacteria.

[Diagram: Sequence of icons showing dewing, frosting, defrosting, drying, and sterilization at 48°C.]

Learn more at www.tcl.com/au

Models: TCD71D1HWH-DV, TCD85D1HWH-DV, TCD100D1HWH-DV, TCD125D1HWH-DV, TCD71D1HWH-DVI, TCD85D1HWH-DVI, TCD100D1HWH-DVI, TCD125D1HWH-DVI, TCD71D1HWH-DVO, TCD85D1HWH-DVO, TCD100D1HWH-DVO, TCD125D1HWH-DVO, TCD71D1HWH High Static Ducted System, High Static Ducted System, Static Ducted System, Ducted System

File Info : application/pdf, 2 Pages, 2.20MB

PDF preview unavailable. Download the PDF instead.

Ducted AC Flyer 2 HR 250715

References

Adobe PDF Library 17.0 Adobe InDesign 20.4 (Macintosh)

Related Documents

Preview TCL Air Conditioner Extended Warranty Terms and Conditions
This document outlines the terms and conditions for TCL's Air Conditioner Extended Warranty Promotion, offering an additional 2 years of coverage for eligible TCL Multi Split, Split Wall Mounted, and Ducted air conditioners purchased in Australia.
Preview TCL Q-Series Heat Pump Window Air Conditioner User Manual
Comprehensive user manual for the TCL Q-Series Heat Pump Window Air Conditioner. Includes setup, installation, operation, maintenance, troubleshooting, and warranty information.
Preview TCL 23 SEER T Series Air Conditioner Technical Specifications
Comprehensive technical specifications for TCL's 23 SEER T series air conditioners, detailing model numbers, cooling and heating performance, energy efficiency ratings (SEER2, EER2, HSPF2, COP2), electrical data, dimensions, weights, refrigerant type, and operating conditions.
Preview TCL Smart Wifi Ceiling Mounted Multi Cassette Air Conditioner User and Installation Manual
Comprehensive user and installation manual for TCL Smart Wifi Controlled Ceiling Mounted Multi Cassette Air Conditioners, covering models like iQool-C2MS12K12K and iQool-C3MS9K9K9K. Includes safety, operation, Wi-Fi setup, installation, maintenance, and troubleshooting.
Preview TCL Split Type Air Conditioner Instruction Manual
This instruction manual provides comprehensive guidance on the operation, installation, maintenance, and troubleshooting of TCL Split Type Air Conditioners, specifically for multi-split systems. It covers safety precautions, remote controller functions, operating modes, installation procedures, and error codes.
Preview TCL TAC-24CHSD/TPH11IT BreezeIN Series 7.2KW Reverse Cycle Air Conditioner Specifications
Detailed specifications for the TCL TAC-24CHSD/TPH11IT BreezeIN Series 7.2KW Reverse Cycle Air Conditioner, including cooling/heating capacity, features, electrical data, dimensions, and rated values.
Preview TCL Smart Control Quick Start Guide: TCL Home & Google Home
A quick start guide for TCL smart air conditioners, detailing how to set up and use the TCL Home app and Google Home for control. Covers Wi-Fi requirements, app installation for iOS and Android, account login, adding the air conditioner, controlling features like mode, fan speed, and temperature, setting timers and reservations, self-diagnosis, and voice control via Google Home.
Preview TCL Smart Control Quick Start Guide: TCL Home & Google Home
A quick start guide for TCL's Smart Control feature, covering setup and usage with both the TCL Home app and Google Home for air conditioners. Includes Wi-Fi requirements, app installation for Android and iOS, account login, device addition, and voice control instructions.