Nice OX2UBP Hardware Interface with 2 Relay Outputs

Instructions for the Fitter

1 - WARNING

Warning! – For personal safety, it is important to observe these instructions.

Warning! – All installation, connection, programming, and maintenance operations of the product must be carried out exclusively by a qualified and expert technician!

Observe the following warnings:

2 - PRODUCT DESCRIPTION AND INTENDED USE

OX2UBP is a hardware interface with 2 relay outputs equipped with an SM connector for radio receivers. The relay outputs are of the “dry contact” type, therefore the device can be used with any type of control unit equipped with inputs for opening, closing, or step-by-step commands.

It can be wall-mounted using screws (A) or an adhesive strip (B) [See Figure 1].

3 - INSTALLATION AND ELECTRICAL CONNECTIONS

IMPORTANT! It is necessary to have a radio receiver of the XI family (OXIR10, OXIBD, OXILR) with the relative instruction manual, to be consulted for all programming activities.

Warning! – To control the two relays, the OX2UBP receiver only exploits the first two digital outputs (out of the four available) of the receiver. The transmitter button to be associated with the relay output must therefore be memorized in the receiver in Mode II on function 1 or 2.

Warning! – Before inserting or removing the receiver, disconnect the power supply.

To insert the radio receiver, perform the operation described in [See Figure 2].

[See Figure 3] shows the terminals where the following electrical connections can be made:

The antenna slot is located on the receiver.

Selection Jumper (JP)

Depending on the supply voltage, insert or remove the jumper (JP) as shown in [See Figure 3].

How to obtain “NC” contacts

The outputs control 2 relays with “NO” (normally open) contacts. Should it be necessary to control relays with “NC” (normally closed) contacts, proceed as explained below:

  1. Disconnect the power supply.
  2. Remove the XI receiver inserted (C) [See Figure 4].
  3. Open the plastic elements (D) as shown in [See Figure 4].
  4. Carefully extract the board (E) and turn it so that the soldered side faces the observer [See Figure 5].
  5. Carry out the following operations on the soldered side [See Figure 6]:
    • Cut the section of the track at point “X”.
    • Join the pads in point “Y” with a drop of tin.

Note: These changes can be made to one relay or both, depending on your necessities.

4 - PRODUCT DISPOSAL

This product is made of various types of materials, some of which can be recycled while others must be scrapped. Seek information on the recycling and disposal systems envisaged in the local regulations in your area for this product category.

Warning! – Certain parts of the product can contain pollutants or dangerous substances that, if dispersed into the environment, could be detrimental to the environment itself and to human health.

As indicated by the adjacent symbol [Recycling symbol ♻️], it is forbidden to dispose of this product together with common household waste. Separate the waste into categories for disposal, according to the methods set forth in the regulations in force in your area, or return the product to the retailer when purchasing a new equivalent product.

5 - PRODUCT TECHNICAL SPECIFICATIONS

Notes:

Models: OX2UBP Hardware Interface for Radio Receivers with SM Connector, OX2UBP, Hardware Interface for Radio Receivers with SM Connector, SM Connector, Hardware Interface for Radio Receivers, Radio Receivers, Receivers

File Info : application/pdf, 2 Pages, 1,011.91KB

PDF preview unavailable. Download the PDF instead.

instrukcja-nice-ox2ubp-interfejs-do-radioodbiornikow-nice

References

Adobe InDesign CC 13.1 (Macintosh) Adobe PDF Library 15.0

Related Documents

Preview Nice OX2UBP Hardware Interface with 2 Relay Outputs - User Manual
This document provides instructions for the Nice OX2UBP hardware interface, detailing its installation, electrical connections, intended use, and technical specifications. It includes information on converting relay outputs from normally open (NO) to normally closed (NC) and guidelines for product disposal.
Preview Nice MC800 Control Unit: Installation and User Manual
Comprehensive guide for the Nice MC800 control unit, covering installation, electrical connections, programming, safety precautions, and troubleshooting for automated gate systems.
Preview Nice Robus RBS400, RBS600, RBS600HS Sliding Gate Operator Installation and Operation Manual
Comprehensive guide for the installation, programming, and maintenance of Nice Robus sliding gate operators (RBS400, RBS600, RBS600HS). Covers safety precautions, product description, electrical connections, setup, radio programming, troubleshooting, and technical specifications.
Preview Nice BiDi-Awning Bidirectional Module for External Tubular Motors - Installation and User Manual
Comprehensive guide for the Nice BiDi-Awning bidirectional module, detailing installation, setup, and operation for external tubular motors. Covers safety precautions, product description, wiring, transmitter memorization (Modes I and II), calibration, partial positions, virtual limit settings, and technical specifications.
Preview Nice OXILR/OXILR/A Radio Receiver Installation and Operation Manual
This document provides instructions and warnings for the installation and use of the Nice OXILR/OXILR/A radio receiver. It covers product description, installation, memorization of transmitters, other functions, technical specifications, and product disposal.
Preview NICE R2 Radio Receiver: Installation and Operation Guide
Comprehensive guide for the NICE R2 radio receiver, covering installation, transmitter memorization (modes 1 and 2), remote memorization, technical specifications, and safety warnings. Compatible with GTX4 transmitters.
Preview Nice O-Box / O-BoxB Interface: Operation and Programming Manual
Comprehensive guide to the Nice O-Box and O-BoxB interface, detailing product features, hardware connections, software usage, and programming for automation systems. Includes multi-language support.
Preview Nice IT4WIFI: BusT4 WiFi Interface Installation Guide
Comprehensive guide for installing and setting up the Nice IT4WIFI, a WiFi interface for Nice Gate & Door automation systems using the BusT4 protocol. Covers setup, operation, technical specifications, and safety.