Installation Instructions
This section provides a step-by-step guide for installing the Arpha AL302 electronic lock.
1. Installation Overview
An overview of the installation process is provided.
2. Preparing Door
Prepare the door according to the provided template. Skip this step if the door has pre-drilled holes.
3. Install Latch and Strike Plate
Install the enclosed latch and strike plate. Ensure the deadbolt latch is retracted during installation. Adjust the backset to 2-3/8" or 2-3/4" as needed.
4. Install Exterior Assembly
Secure the mounting plate to the door. Attach the exterior assembly, ensuring the tailpiece goes through the deadbolt latch set in the vertical position. Route the control wire through the door under the deadbolt latch set. Check that the rubber gasket is secured on the exterior assembly.
5. Install Interior Assembly
Work with the door open. Carefully insert the control wire into the wire connector. Ensure the connector aligns with the control wire. Secure the interior assembly.
6. Install Interior Assembly (Continued)
Ensure the knob is in the correct position. Be careful not to pinch the control wire during assembly.
7. Install Batteries and Cover
Install four (4) high-quality AA alkaline batteries. The keypad will illuminate, and the lock will perform an automatic handing detection sequence (locking and unlocking motions). Wait for the lock to beep and the keypad to flash before touching the keypad.
8. Testing Operation
Test the lock button with the door open. Test unlocking using the keypad. Ensure the latch opens and closes easily. If not, recheck previous installation steps.
9. Emergency Power Supply
In case of low battery, a micro USB cable can be used with a portable battery to power the keypad lock.
AL302 Programming Instructions
Follow these steps to program and manage your Arpha AL302 electronic lock using the Arpha app.
1. Download the App
Download the ARPHA App from the App Store (iOS) or Google Play (Android).
2. Sign Up Account
Create your account within the ARPHA app and follow the setup instructions.
3. Add Device to Your App
3.1 Automatically add the device: Navigate to "Add Device" > "Auto Scan".
3.2 Manually add the device: Navigate to "Add Device" > "Security & Video" > "Lock (BLE)" > "Next".
4. App Settings
Customize settings such as device nickname, third-party voice services, and manage notifications.
5. Lock Management
Manage lock operations, view device information, check alerts and unlocking records, and add users or passwords.
6. Additional Programming Functions
Programming Symbols:
- Lock/Clear: ?
- Unlock/Programming: ?
Automatic Lock Function: Set the lock to automatically close after opening. Time range: 5-900 seconds. Enter A[Time Value] (e.g., A05 for 5 seconds). To cancel, set time to 00 (e.g., A00).
Temporarily Disable Auto-Lock: Unlock the door, then manually turn the knob to locked within 10 seconds. Wait 2 seconds, then turn back to unlock. Auto-Lock is disabled.
Restore Auto-Lock: Manually turn the knob to locked, wait 2 seconds, or press the Lock button.
Vacation Mode: Enables low-power consumption mode, disabling all functions. ENABLE: Lock the door. DISABLE: Press and hold TOT for over 3 seconds, then input [Unlock Code].
Secure Lock-out Period: After 4 incorrect code attempts, the keypad shuts down for 60 seconds, with warning sounds and red LED flashes.
7. Additional Programming Functions (Continued)
Sound On and Off: Use 61 for Sound Off (factory setting is sound on) or 62 for Sound On.
Restore Factory Settings: Remove one battery for 10 seconds. Reinsert, wait for beeps, press 3 three times within 3 seconds. The lock will beep and the light indicator will turn green.
Low Battery Warning: Beeps and LED flashes red 7 times. Replace with new alkaline batteries.
Consumer Friendly Message Guide:
- Unlock/Valid programming: 1 long beep and green LED.
- Lock: 2 short beeps and red LED.
- Invalid Programming: 2 short beeps and flashing red LED.
- Low Voltage: Short beeps and flashing red LED 7 times.
- Super Low Voltage: 4 short beeps and flashing red LED 4 times.
- 4 Incorrect code entry attempts: 2 short beeps and red LED each attempt.
- Power on: 1 long beep with red light, 1 short beep with green light.
- Chip Reset: 1 long beep and 1 short beep with green+red light.
- Lock Error: 3 long beeps, flashing red LED 3 times.
- Repeat operation after Lock Error: 2 short beeps three times, flashing red LED 6 times.
Customer Service
Arpha offers a one-year warranty and lifetime technical support. For assistance, contact support@arpha.com.
Notice
FCC Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: no harmful interference, and acceptance of received interference. Modifications not approved by the responsible party may void the user's authority to operate the equipment.
This equipment has been tested and found to comply with Class B digital device limits, pursuant to Part 15 of the FCC Rules. These limits provide reasonable protection against harmful interference in residential installations. The equipment generates, uses, and can radiate radio frequency energy. If not installed and used per instructions, it may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If interference occurs, try to correct it by:
- Reorienting or relocating the receiving antenna.
- Increasing the separation between the equipment and receiver.
- Connecting the equipment to an outlet on a different circuit than the receiver.
- Consulting the dealer or an experienced radio/TV technician.