Honeywell Home T6 Pro Z-Wave Programmable Thermostat
Model: TH6320ZW
Getting Started
Visit honeywellhome.com for a complete user guide.
How to Use Your Thermostat
The T6 Pro Z-Wave thermostat offers intuitive control over your home's heating and cooling.
Thermostat Display Overview
The main screen provides essential information:
- Desired Temperature: Displays the target indoor temperature you have set.
- Current Conditions: Shows the current indoor temperature and/or the relative indoor humidity. Touch the screen to toggle between these readings.
- System Mode: Indicates the current operating mode of your HVAC system (e.g., Heat, Cool, Off).
- Fan Status: Displays the current fan setting (e.g., Auto, On, Circulate).
- Z-Wave Connection Status: Shows the status of the thermostat's connection to your Z-Wave network.
Adjusting Temperature
Use the '+' or '-' buttons directly on the thermostat to set your desired temperature.
System Mode Selection
To change the system mode, touch the 'Mode' button. Available options include:
- Auto (if enabled)
- Heat
- Cool/Off
- EM Heat (Emergency Heat - available if installed and configured)
Fan Mode Selection
To select the fan operation, touch the 'Fan' button. Options are:
- Auto
- On
- Circulate
Menu Navigation
Access advanced features such as programming a schedule and other customizable settings by touching the 'Menu' button.
Power and Z-Wave Setup
The thermostat's screen will remain lit for 45 seconds after changes if powered by a 24 VAC source. If powered solely by batteries, the screen stays lit for 8 seconds. To include or exclude the thermostat from your Z-Wave network, navigate to the thermostat's MENU and select Z-WAVE SETUP.
Contact Information
For general assistance, visit honeywellhome.com or call 1-800-468-1502. You can also find us on social media: Twitter: @Honeywell_Home, Facebook: Honeywell Home.
Technical Support
For technical problems, please contact your company representative or consult the support resources provided by Resideo.
Technical Specifications
Power Requirements
Battery Power: Requires 3 x AA alkaline batteries. C-wire input: 18-30 VAC, 50/60 Hz.
Electrical Ratings
| Terminal | Voltage (50/60 Hz) | Running Current | Terminal | Voltage (50/60 Hz) | Running Current |
|---|---|---|---|---|---|
| W Heating | 18-30 Vac | 0.02-1.0 A | Y2 Compressor Stage 2 | 18-30 Vac | 0.02-1.0 A |
| (Powerpile) | 750 mV DC | 100 mA DC | G Fan | 18-30 Vac | 0.02-0.5 A |
| W2 (Aux) Heating | 18-30 Vac | 0.02-1.0 A | O/B Changeover | 18-30 Vac | 0.02-0.5 A |
| E Emergency Heat | 18-30 Vac | 0.02-0.5 A | L/A Input | 18-30 Vac | 0.02-0.5 A |
| Y Compressor Stage 1 | 18-30 Vac | 0.02-1.0 A |
Regulatory Information
FCC Compliance: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For users in the USA, changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Additional FCC information is available at https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx.
IC Compliance: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Caution: To prevent possible compressor damage, do not operate the cooling system when the outdoor temperature is below 50°F (10°C).