Safety Human Exposure
1.1 Radio Frequency Exposure Compliance
1.1.1 Electromagnetic Fields
RESULT
Test item: Self-ballasted LED lamps
Identification / Type No.: LED2401G5NA
FCC ID: FHO-LED2401G5NA
IC: 10912A-LED2401G5NA
Test standard: CFR47 FCC Part 2: Section 2.1091, CFR47 FCC Part 1: Section 1.1310, FCC KDB Publication 447498 D01 V06, RSS-102 Issue 6 December 2023
Status: Pass
Product Classification
This device is defined as a transmitting device designed for use in other than fixed locations. It is generally intended for use in a manner such that a separation distance of at least 20 centimeters is normally maintained between the RF source's radiating structure(s) and the body of the user or nearby persons.
Maximum antenna gain: 1.18 dBi
FCC Radio Frequency Exposure Limit
Frequency range (MHz) | Electric field strength (V/m) | Magnetic field strength (A/m) | Power density (mW/cm²) |
---|---|---|---|
300-1,500 | -- | -- | f/1500 |
1,500-100,000 | -- | -- | 1.0 |
Radio Frequency Exposure Calculation Formula
The power density (S) can be calculated using the following formulas:
S = PG / 4πR²
where:
- S = power density (in appropriate units, e.g. mW/cm²)
- P = power input to the antenna (in appropriate units, e.g., mW)
- G = power gain of the antenna in the direction of interest relative to an isotropic radiator
- R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)
or:
S = EIRP / 4πR²
where: EIRP = equivalent (or effective) isotropically radiated power
IC Field reference level exposure exemption limits
Field reference level (FRL) exposure evaluation is required if the separation distance between the user and/or bystander and the device's radiating element is greater than 20 cm (i.e. mobile devices), except when the device operates under the following conditions:
- Below 20 MHz: source-based, time-averaged maximum EIRP is ≤ 1 W (adjusted for tune-up tolerance).
- At or above 20 MHz and below 48 MHz: source-based, time-averaged maximum EIRP is ≤ 4.49/f0.5 W (adjusted for tune-up tolerance), where f is in MHz.
- At or above 48 MHz and below 300 MHz: source-based, time-averaged maximum EIRP is ≤ 0.6 W (adjusted for tune-up tolerance).
- At or above 300 MHz and below 6 GHz: source-based, time-averaged maximum EIRP is ≤ 1.31×10-2f0.6834 W (adjusted for tune-up tolerance), where f is in MHz.
- At or above 6 GHz: source-based, time-averaged maximum EIRP is ≤ 5 W (adjusted for tune-up tolerance).
a) EUT RF Exposure Evaluation standalone operations
FCC
Mode | *Measured RF Output Power (dBm) | EIRP (dBm) | Distance (cm) | Power Density (mW/cm²) | Limit (mW/cm²) |
---|---|---|---|---|---|
BLE | 7.9 | 9.08 | 20 | 0.0016 | 1 |
Zigbee | 8.4 | 9.58 | 20 | 0.0018 | 1 |
Thread | 8.4 | 9.58 | 20 | 0.0018 | 1 |
IC
Mode | Frequency (MHz) | *Measured RF Output Power (dBm) | EIRP (dBm) | EIRP (W) | Limit (W) |
---|---|---|---|---|---|
BLE | 2440 | 7.9 | 9.08 | 0.0081 | 2.7053 |
Zigbee | 2405 | 8.4 | 9.58 | 0.0091 | 2.6787 |
Thread | 2445 | 8.4 | 9.58 | 0.0091 | 2.7091 |
Note:
- BLE RF Output Power: Refer CN25821F 001
- Zigbee Output Power: Refer CN25QMEC 001
- Thread Output Power: Refer CN25FULG 001
- BLE, Zigbee, and Thread share one RF chip and antenna, so simultaneous transmission evaluation is not required.
Conclusion
The separation distance between the antenna and human is larger than 20 cm during normal use. Therefore, the maximum calculation results presented above meet the requirements of the Radio Frequency Exposure limit.