Beko BLSD3577 Refrigerator Product Information Sheet
Supplier Information
Supplier Name: Beko
Supplier Address: Arctic S.A Gaesti, Dambovita, 13 Decembrie Street, No 210, Romania
Model Identifier: BLSD3577
Appliance Type
Type of refrigerating appliance: Refrigerator
Design Type: Built-in
Low-noise appliance: No
Wine storage appliance: No
Other refrigerating appliance: No
General Product Parameters
Parameter | Value | Parameter | Value |
---|---|---|---|
Overall dimensions (millimeter) Height | 1775 | Total volume (dm³ or l) | 309 |
Width | 540 | ||
Depth | 545 | ||
EEI | 124 | Energy efficiency class | F |
Airborne acoustical noise emissions (dB(A) re 1 pW) | 36 | Airborne acoustical noise emission class | C |
Annual energy consumption (kWh/a) | 141.99 | Climate class | SN-T |
Minimum ambient temperature (°C) for which the refrigerating appliance is suitable | 10 | Maximum ambient temperature (°C) for which the refrigerating appliance is suitable | 43 |
Winter setting | No |
Compartment Parameters
Compartment type | Compartment Volume (dm³ or l) | Recommended temperature setting for optimised food storage (°C) | Freezing capacity (kg/24 h) | Defrosting type (auto-defrost=A, manual defrost=M) |
---|---|---|---|---|
Pantry | No | - | - | - |
Wine storage | No | - | - | - |
Cellar | No | - | - | - |
Fresh food | Yes (309.0) | 4.0 | - | M |
Chill | No | - | - | - |
0-star or ice-making | No | - | - | - |
1-star | No | - | - | - |
2-star | No | - | - | - |
3-star | No | - | - | - |
4-star | No | - | - | - |
2-star section | No | - | - | - |
Variable temperature compartment | - | - | - | - |
For 4-star compartments Fast freeze facility | - | No | - | - |
Light Source Parameters
Type of light source: LED
Energy efficiency class: G
Manufacturer Guarantee
Minimum duration of the guarantee offered by the manufacturer: Not specified
Additional Information
Weblink to manufacturer's website: http://support.beko.com
Information determined in accordance with Commission Delegated Regulation (EU) 2019/2015.
Changes to these items shall not be considered relevant for the purposes of point 4 of Article 4 of Regulation (EU) 2017/1369.
Technical Documentation
General Product Specifications
Parameter | Value | Parameter | Value |
---|---|---|---|
Annual energy consumption (kWh/a) | 142 | Auxiliary energy (kWh/a) | 0 |
Standard annual energy consumption (kWh/a) | 114.30 | EEI (%) | 124 |
Temperature rise time (h) | Combi parameter | 1.00 | |
Door heat loss factor | 1.000 | Load factor | 1.0 |
Anti-condensation heater type | None |
Additional product specifications for refrigerating appliances, except for low noise refrigerating appliances
Parameter | Value | Parameter | Value |
---|---|---|---|
Daily energy consumption at 16 °C (kWh/24h) | 0.185 | Daily energy consumption at 32 °C (kWh/24h) | 0.593 |
Incremental defrost and recovery energy consumption at 16 °C (Wh) | - | Incremental defrost and recovery energy consumption at 32 °C (Wh) | - |
Defrost interval at 16 °C (h) | - | Defrost interval at 32 °C (h) | - |
Additional product specifications for low noise refrigerating appliances
Parameter | Value | Parameter | Value |
---|---|---|---|
Daily energy consumption at 25 °C (kWh/24h) | - | Defrost interval at 25 °C (h) | - |
Compartment specifications
Compartment type | Target temperature (°C) | Thermodynamic parameter (rc) | Nc | Mc | Defrost factor (Ac) | Built-in factor (Bc) |
---|---|---|---|---|---|---|
Pantry | - | - | - | - | - | - |
Wine storage | - | - | - | - | - | - |
Cellar | - | - | - | - | - | - |
Fresh food | 4 | 1.00 | 75 | 0.12 | 1.00 | 1.02 |
Chill | - | - | - | - | - | - |
0-star or ice-making | - | - | - | - | - | - |
1-star | - | - | - | - | - | - |
2-star | - | - | - | - | - | - |
3-star | - | - | - | - | - | - |
4-star | - | - | - | - | - | - |
2-star section | - | - | - | - | - | - |
Variable temperature compartment | - | - | - | - | - | - |
Calculations and Standards
Annual energy consumption (kWh/a), T average (°C)
Formula (2): Edaily = P x 24 + (ΔΕdf x 24) / Δtdf
Where:
- Edaily is the energy in Wh over a period of 24 h
- P is the steady state power in watt for the selected temperature control setting as per Annex B.
- ΔΕdf is the representative incremental energy for defrost and recovery in Wh in accordance with Annex C (see C.5).
- Δtdf is the estimated defrost interval in hours in accordance with Annex D.
Formula (3): Taverage = Tss + (ΔΕdf / Δtdf)
Note: EN 60552-3:2020, 6.8.2 clause, Equation 2-3.
Annual Energy, Daily energy consumption at 16 °C / 32 °C (kWh/24h)
Formula (4): AE = 365 × Edaily/L + Eaux
Formula: Edaily = 0,5 × (E16 + E32)
Note: EN 60552-3:2020, 6.8.2 clause, Equation 4, (EU) 2019/2019 Ecodesign Requirements Directive
Standard annual energy consumption (kWh/a)
SAE, expressed in kWh/a and rounded to two decimal places, is calculated as follows:
SAE = C × D × A × B × [Vc/V] × (N + V × r × M)
The modelling parameters are set out in Table 4.
Compartment type | N | M | C | r(°) |
---|---|---|---|---|
Pantry | 0.35 | - | - | - |
Wine storage | 0.60 | - | - | - |
Cellar | 0.60 | - | - | - |
Fresh food | 1.00 | 75 | 0.12 | 1.00 |
Chill | 1.10 | - | - | - |
0-star & ice-making | 1.20 | - | - | - |
1-star | 1.50 | - | - | - |
2-star | 1.80 | 138 | 0.15 | 1.00 |
3-star | 2.10 | - | - | - |
Freezer (4-star) | 2.10 | - | - | - |
(*) r = (Ts - Tc)/20; with Ts = 24 °C and Tc with values as set out in Table 3.
(**) C for combi appliances with 3- or 4-star compartments is determined as follows:
where frzf is the 3- or 4-star compartment volume Vc as a fraction of V with frzf = Vc/V:
- if frzf ≤ 0,3 then C = 1,3 +0,87 × frzf;
- else if 0,3 < frzf < 0,7 then C = 1,87 - 1,0275 × frzf;
- else C = 1,15.
C between 1,15 and 1,56 for combi appliances with 3- or 4-star compartments (6), 1,15 for other combi appliances, 1,00 for other refrigerating appliances
Compartment type | A (Manual defrost) | B (Auto-defrost) | D (Freestanding appliance) | D (Built-in appliance) | ≤2 (*) | 3 (*) | 4 (2) | > 4 () |
---|---|---|---|---|---|---|---|---|
Pantry | - | - | - | - | - | - | - | - |
Wine storage | 1.00 | - | - | - | - | - | - | - |
Cellar | - | 1.00 | - | - | - | - | - | - |
Fresh food | - | 1.03 | 1.00 | 1.00 | 1.02 | 1.03 | 1.035 | 1.05 |
Chill | - | - | - | - | - | - | - | - |
0-star & ice-making | 1.10 | - | - | - | - | - | - | - |
1-star | - | 1.10 | - | - | - | - | - | - |
2-star | - | - | - | - | - | - | - | - |
3-star | - | - | - | - | - | - | - | - |
Freezer (4-star) | - | - | - | - | - | - | - | - |
(*) number of external doors or compartments, whichever is lowest.
Note: (EU) 2019/2019 Ecodesign Requirements Directive, Clause 5, Table 4-5
5. Determination of the EEI:
EEI, expressed in % and rounded to the first decimal place, calculated as:
EEI = AE/SAE.
Note: (EU) 2019/2019 Ecodesign Requirements Directive, Clause 5
Auxiliary energy (kWh/a)
Formula (40): Wheaters = ∑(Ri × PHi) × 1.3
Relative Humidity RH band mid-point | Probability Ri | Probability at 16 °C | Probability at 22 °C | Probability at 32 °C | Heater W at 16 °C | Heater W at 22 °C | Heater W at 32 °C |
---|---|---|---|---|---|---|---|
0 to 10% | 5% | 0.00% | 0.00% | 0.34% | PH1 | PH11 | PH21 |
10 to 20% | 15% | 0.61% | 6.86% | 2.01% | PH2 | PH12 | PH22 |
20 to 30% | 25% | 3.11% | 14.57% | 1.61% | PH3 | PH13 | PH23 |
30 to 40% | 35% | 5.03% | 14.83% | 0.86% | PH4 | PH14 | PH24 |
40 to 50% | 45% | 5.09% | 11.67% | 0.18% | PH5 | PH15 | PH25 |
50 to 60% | 55% | 4.67% | 8.31% | 0.01% | PH6 | PH16 | PH26 |
60 to 70% | 65% | 3.39% | 5.54% | 0.00% | PH7 | PH17 | PH27 |
70 to 80% | 75% | 3.17% | 2.51% | 0.00% | PH8 | PH18 | PH28 |
80 to 90% | 85% | 2.85% | 0.66% | 0.00% | PH9 | PH19 | PH29 |
90 to 100% | 95% | 2.05% | 0.07% | 0.00% | PH10 | PH20 | PH30 |
Note: EN 62552-3:2020, Annex F 2.5, Equation 40, Table F.1
Incremental Defrost and Recovery Energy Consumption
Formula (19): ΔΕdf = (Eend-F - Estart-D) - ((PSS-D + PSS-F)/2) × (tend-F - tstart-D)
Formula (22): ΔΕdf = ΣΔΕdfj / m
Note : EN 62552-3:2020 Annex C, Clause C.3.3, Equation 19-22
Defrost Interval at 16 / 32 °C (h)
For Compressor Run Time Defrost Controller
Formula (26): Δtdf = (Δtrt - Δtdr - Δtdh) / CRtss + Δtdxy
For Variable Defrost Controller
Formula (27): Δtdf32 = (Δtd-max - Δtd-min) / [0.2 × (Δtd-max - Δtd-min) + Δtd-min]
Δtdf16 = 2 × Δtdf16