DocumentDocument24V/40A DIN Rail Type Uninterruptible DC-UPS Module DUPS40 User's Manual File Name:DUPS40-SPEC 2022-03-18 24V/40A DIN Rail Type Uninterruptible DC-UPS Module DUPS40 SPECIFICATION MODEL DUPS40 DC UPS INPUT DC UPS OUTPUT BATTERY NORMAL INPUT VOLTAGE INPUT VOLTAGE RANGE RATED CURRENT VOLTAGE RANGE DISCHARGE CURRENT RANGE CHARGING CURRENT NORMAL BATTERY VOLTAGE BATTERY TYPE EXTERNAL BATTERY CAPACITIES BATTERY POLARITY PROTECTION SHORT CIRCUIT 24Vdc 24 ~ 29Vdc 40A 21 ~ 29Vdc 0 ~ 40A 2A 24Vdc ( 2 x 12Vdc in series or 1 x 24Vdc) Lead-acid battery 4AH ~ 135AH Protected by internal detection, No Damage, recovers automatically after fault conduction is removed This protection only works when batteries are not connected, No Damage. External fuse is recommended when batteries are connected. OVER DISCHARGE CURRENT 42~46A,After 3 sec., unit will cut-off battery discharging by relay BATTERY DEEP DISCHARGE Cut-off battery discharging by relay RELAY CONTACT RATINGS (max.) DC BUS OK 30VDC/1A resistive load Relay contact : Short when DC voltage between 21~29V(±2%), relay contacts LED(Green) : DC BUS OK : light ; DC BUS fail : dark FUNCTION BATTERY FAIL Short when battery voltage falls below 22V(±2%) or battery failure is observed through the battery test function, relay contacts Note.2 LED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : dark BATTERY DISCHARGE Relay contact : Short when battery in discharge condition, relay contacts LED(Yellow) : light : Battery discharging ; dark : Battery is not discharging or discharging current < 2.0A COOLING WORKING TEMP. Free air convection Note.3 -30 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 5 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP. -40 ~ +85 TEMP. COEFFICIENT ±0.03%/ (0 ~ 60) VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE Note.4 2000 meters/OVC II SAFETY STANDARDS EAC TP TC 004 approved WITHSTAND VOLTAGE IP/OP - Chassis : 0.5KVac ; IP/OP- Relay : 0.5KVac ; Relay - Chassis : 0.5KVac ISOLATION RESISTANCE IP/OP - Chassis, IP/OP- Relay, Relay - Chassis:>100M Ohms / 500Vdc / 25/ 70% RH Parameter Standard Test Level / Note EMC EMISSION SAFETY & EMC (Note.5) Conducted ----- ----- Radiated BS EN/EN55032(CISPR32) Class B Voltage Flicker ----- ----- Harmonic Current ----- ----- BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3 Parameter Standard Test Level / Note EMC IMMUNITY OTHERS MTBF DIMENSION PACKING ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact; criteria B Level 2, 4KV air ; Level 1, 2KV contact; criteria A Radiated BS EN/EN61000-4-3 Level 3, 10V/m ; criteria A EFT / Burst BS EN/EN61000-4-4 Level 3, 2KV ; criteria A Surge BS EN/EN61000-4-5 Level 3, 0.5KV(DC input ports) Conducted BS EN/EN61000-4-6 Level 3, 10V ; criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m ; criteria A 1376.5K hrs min. Telcordia SR-332 (Bellcore) ; 499.5K hrs min. MIL-HDBK-217F (25) 63*125.2*113.5mm (W*H*D) 0.42Kg; 20pcs/9.4Kg/1.57CUFT NOTE https://www.meanwell.com/serviceDisclaimer.aspx File Name:DUPS40-SPEC 2022-03-18 24V/40A DIN Rail Type Uninterruptible DC-UPS Module Block Diagram LOAD + INPUT + POWER SUPPLY DETECTION CIRCUIT CHARGE CIRCUIT LIMIT MCU RELAY & LED DISPLAY STATUS DC BAT BAT OK FAIL DISCHARGE (GREEN LED) (RED LED) (YELLOW LED) Derating Curve 30A*2 BAT. TEST + OUTPUT 24V BATTERY DETECTION CIRCUIT DUPS40 100 80 75 60 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) Buffering Time Discharge Current 2.5A 5A 10A 20A 30A 40A Buffering Time(Reference) 7.5AH 12AH 15AH 6500s 14500s 19000s 3000s 7000s 9000s 1200s 2400s 3200s 400s 1100s 1500s 120s 450s 600s 25s 200s 280s Buffering time VS Discharge Current (A) LOAD (%) File Name:DUPS40-SPEC 2022-03-18 24V/40A DIN Rail Type Uninterruptible DC-UPS Module Mechanical Specification DUPS40 Case No.979F Unit:mm 113.5 Installation Instruction 125.2 12 34 56 TB2 LED DC OK BAT Fail BAT Discharge TB1 1234 63 Terminal Pin No. Assignment (TB1) Pin No. Assignment 1 BAT INPUT + 2 BAT INPUT 3 DC INPUT 4 DC INPUT + Terminal Pin No. Assignment (TB2) Pin No. Assignment LED 1 2 BAT Discharge YELLOW 3 4 BAT Fail RED 5 6 DC OK GREEN 35 This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) Back View File Name:DUPS40-SPEC 2022-03-18 24V/40A DIN Rail Type Uninterruptible DC-UPS Module Suggested Application 1.Back up connection for AC interruption TB2 24V Battery - + DUPS40 TB1 BAT DC +--+ PSU 24V/40A max. +- DUPS40 Load +- 2.Combine redundancy module (DRDN20 or DRDN40) to back up AC interruption or failure of PSU Vout TB2 TB1 TB2 24V Battery - + DUPS40 TB1 BAT DC +--+ DRDN20 (or DRDN40) Vin +-+- TB3 PSU 1 + - PSU 2 + - Load +- Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:DUPS40-SPEC 2022-03-18