Installation Guide for TOWER models including: Automatic Air Vent, Automatic, Air Vent, Vent

AAV inst

Your Name

Installation Instructions for Automatic Air Vent (AAV) in ...

2024-12-19 — Product Overview. ○ Product Code: AAV. ○ Max Working Pressure: 10 BAR. ○ Working Temperature Range: 0 - 95 °C. ○ Inlet Fitting: 1/2" BSP.


File Info : application/pdf, 4 Pages, 887.59KB

PDF preview unavailable. Download the PDF instead.

AAV inst
Installation Instructions for Automatic Air Vent (AAV) in Sealed Central Heating Systems
Introduction The Automatic Air Vent (AAV) is designed for use in sealed central heating systems. It automatically removes trapped air from the system, ensuring optimal performance, preventing air pockets, and reducing the risk of damage to system components caused by air and corrosion.
Product Overview  Product Code: AAV  Max Working Pressure: 10 BAR  Working Temperature Range: 0 - 95 °C  Inlet Fitting: 1/2" BSP  Material: Brass body  Dimensions: Height: 94mm, Diameter: 33mm  Seal Type: O-ring seal (no need for PTFE tape)  System Compatibility: Suitable for sealed central heating systems  Installation Requirement: Qualified heating engineer

TFC GROUP, TOWER HOUSE, VALE RISE, TONBRIDGE, KENT TN9 1TB

Tel: 01732 351680 Fax: 01732 354445 www.tfc-group.co.uk

Page 1 0f 4

Required Tools and Materials:  Automatic Air Vent (AAV) with O-ring seal  1/2" BSP Tee piece  Wrench or spanner for 1/2" BSP fittings  Pipe cutter (if required)  Cleaning cloth  Central heating system shut-off valve
Installation Procedure: Safety First
 Ensure the sealed central heating system is turned off and completely depressurized.  Allow sufficient time for the system to cool down if it has been operating recently.  Ensure that the work is carried out by a qualified heating engineer.  Select Installation Location
The Automatic Air Vent should be installed at a high point in the sealed central heating system, as air naturally accumulates at elevated points. Typical installation points include near the boiler, radiators, or air separators. A Tee piece with a 1/2" BSP thread is required to connect the AAV to the system. Ensure the selected location has or can accommodate the Tee piece.
Install the Tee Piece (if necessary) If the system does not have a pre-installed 1/2" BSP threaded Tee piece, follow these steps: Isolate the section of the pipework where the Tee piece will be installed by shutting off the water supply and draining the necessary part of the system. Cut the pipe at the chosen location using a pipe cutter, ensuring the cut is clean and even.

TFC GROUP, TOWER HOUSE, VALE RISE, TONBRIDGE, KENT TN9 1TB

Tel: 01732 351680 Fax: 01732 354445 www.tfc-group.co.uk

Page 2 0f 4

Fit the 1/2" BSP Tee piece into the pipework and secure it tightly using appropriate fittings. Ensure the Tee piece is aligned correctly for the AAV to screw into the upward-facing 1/2" BSP threaded port.
Prepare the Pipework: 1. Clean the pipe ends to ensure a good seal and remove any debris or dirt. 2. Install the AAV 3. The AAV is equipped with an O-ring seal, so no PTFE tape is necessary. 4. Screw the AAV into the Tee piece's 1/2" BSP threaded port by hand until snug. 5. Use a wrench or spanner to tighten further, ensuring the unit is secure. Do not over-tighten, as
the O-ring seal will provide a leak-proof connection.
Check the Vent Cap 6. The AAV has a vent cap on top. For normal operation, ensure the vent cap is in the open
position (unscrewed slightly) to allow automatic expulsion of air. 7. If manual venting is needed at any time, the cap can be fully opened to release any trapped
air. 8. Refill the System 9. Refill the sealed central heating system with water, ensuring that no air pockets remain. 10. Bleed the radiators to remove any trapped air from other parts of the system. 11. Pressurize the system according to manufacturer guidelines (up to 10 BAR for this AAV
model).
Test the System:  Turn on the sealed central heating system and allow it to reach operating temperature.  Check for any signs of leakage around the AAV, Tee piece, or other fittings.  Observe the vent to ensure that it is automatically expelling air as intended.

TFC GROUP, TOWER HOUSE, VALE RISE, TONBRIDGE, KENT TN9 1TB

Tel: 01732 351680 Fax: 01732 354445 www.tfc-group.co.uk

Page 3 0f 4

Finalize the Installation: Once the system is running smoothly and free of air, make any necessary adjustments. Ensure that the vent cap is in the correct open position for continued operation.
Maintenance: The Automatic Air Vent requires minimal maintenance. However, periodic checks should be performed to ensure the vent cap is not blocked and that no leaks are present. If the vent becomes clogged or fails to expel air, it may need cleaning or replacement.
Troubleshooting: No air release: Check if the vent cap is fully open. If no air is released despite the presence of air pockets, the vent may be clogged. Water leakage: Ensure that the unit is securely fastened and that the O-ring seal is intact. Tighten the fittings if necessary but avoid over-tightening.
Guarantee: This Automatic Air Vent comes with a 12-month Guarantee from the date of purchase. Refer to the supplier for additional support or replacement if required.

TFC GROUP, TOWER HOUSE, VALE RISE, TONBRIDGE, KENT TN9 1TB

Tel: 01732 351680 Fax: 01732 354445 www.tfc-group.co.uk

Page 4 0f 4



References

PDFlib PDI 9.0.5 (Win32)